Ultraflex™ Tracheobronchial M00576430Recalls & reported problems

Boston Scientific Corporation · Proximal Release Stent System · Class 2 · Implant

All models of Ultraflex Tracheobronchial (25)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08714729837794), received between Dec 13, 2017 and Feb 26, 2019 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Activation, Positioning or Separation Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Activation, Positioning or Separation Problem3
  • Break1
  • Unraveled Material1

Patient problems

  • No Consequences Or Impact To Patient3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 26, 2019Unraveled Material; Activation, Positioning or Separation Problem; Unraveled Material; Activation, Positioning or Separation Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION ON JANUARY 31, 2019 THAT AN ULTRAFLEX TRACHEOBRONCHIAL UNCOVERED PROXIMAL RELEASE STENT WAS TO BE USED DURING A TRACHEOBRONCHIAL STENT PLACEMENT PROCEDURE PERFORMED ON (B)(6) 2019. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE, THE STENT WAS PARTIALLY DEPLOYED AND THE METAL STENT WAS NOTED TO BE FRAYED. THE STENT WAS REMOVED AND THE PROCEDURE WAS COMPLETED WITH ANOTHER ULTRAFLEX TRACHEOBRONCHIAL STENT. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8371367 ↗
  • MalfunctionJun 21, 2018Activation, Positioning or Separation Problem; Activation, Positioning or Separation Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION ON (B)(6) 2018 THAT AN ULTRAFLEX TRACHEOBRONCHIAL UNCOVERED PROXIMAL RELEASE STENT WAS TO BE USED TO TREAT A MALIGNANT STRICTURE IN THE AIRWAY DURING A STENT PLACEMENT PROCEDURE PERFORMED ON (B)(6) 2018. ACCORDING TO THE COMPLAINANT, DURING STENT DEPLOYMENT, THE SHAFT BOWED AND THE STENT AND DELIVERY SYSTEM MOVED IN AN UNDESIRED LOCATION. THE STENT WAS PARTIALLY DEPLOYED ON THE DELIVERY SYSTEM AND COULD NOT BE MOVED BACK TO THE DESIRED LOCATION. THE STENT AND DELIVERY SYSTEM WERE REMOVED AND A DIFFERENT DEVICE WAS PLACED TO COMPLETE THE CASE. THERE WERE NO COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE FINE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7627688 ↗
  • MalfunctionDec 13, 2017Break; Activation, Positioning or Separation Problem; Break; Activation, Positioning or Separation Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION ON (B)(6) 2017 THAT AN ULTRAFLEX TRACHEOBRONCHIAL STERILE UNCOVERED PROXIMAL RELEASE STENT WAS TO BE USED TO TREAT A MALIGNANT SUBCARINAL STENOSIS DURING A BRONCHOSCOPY WITH STENT PLACEMENT PROCEDURE PERFORMED ON (B)(6) 2017. REPORTEDLY, THE PATIENT¿S AIRWAY WAS TIGHT AND WAS DILATED PRIOR TO STENT PLACEMENT. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE, THE PHYSICIAN STARTED DEPLOYING THE STENT, HOWEVER, THE STENT DEPLOYMENT SUTURE BROKE NEAR THE DISTAL TIP. THE PARTIALLY DEPLOYED STENT WAS REMOVED FROM THE PATIENT AND THE PROCEDURE WAS NOT COMPLETED AS THE SAME DEVICE WAS UNAVAILABLE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT¿S CONDITION AT THE CONCLUSION WAS REPORTED TO BE FINE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7114331 ↗

Other Prosthesis, tracheal, expandable devices

All Prosthesis, tracheal, expandable devices →