HI-TORQUE IRON MAN 1001309JRecalls & reported problems
Abbott Vascular Inc. · HI-TORQUE IRON MAN Guide Wire .014 J Tip 3.0 cm x 190 cm · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08717648015748), received between Jan 28, 2019 and Jan 28, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Difficult to Remove” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Difficult to Remove1
- Material Separation1
- Stretched1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 28, 2019Difficult to Remove; Material Separation; Stretched; Difficult to Remove; Material Separation; Stretched
IT WAS REPORTED THAT PROCEDURE WAS TO TREAT A MODERATELY TORTUOUS AND MODERATELY CALCIFIED RIGHT CORONARY ARTERY THAT WAS 70% STENOSED. AN UNSPECIFIED BALANCE MIDDLE WEIGHT (BMW) GUIDE WIRE MET RESISTANCE WITH AN UNSPECIFIED BALLOON CATHETER DURING ADVANCEMENT. THEREFORE, A 014 IRON MAN GUIDE WIRE WAS USED AS A BUDDY WIRE; HOWEVER, THE IRON MAN GUIDE WIRE BECAME ENTANGLED WITH THE BMW GUIDE WIRE DURING REMOVAL. THE IRON MAN GUIDE WIRE COIL THEN UNRAVELED AND THE TIP SEPARATED OUTSIDE THE ANATOMY WHEN IT WAS REMOVED INDEPENDENTLY. THE BMW GUIDE WIRE WAS REMOVED AFTER THE PROCEDURE WAS COMPLETED AND IT WAS NOT DAMAGED. THERE WERE NO ADVERSE PATIENT EFFECTS AND NO CLINICALLY SIGNIFICANT DELAY IN THE PROCEDURE. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8283038 ↗
Other WIRE, GUIDE, CATHETER devices
- HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II 1009664Abbott Vascular Inc. · WIRE, GUIDE, CATHETER321 reports
- SYNCHRO 14 M00313010Stryker Corporation · WIRE, GUIDE, CATHETER2 recalls220 reports
- PressureWire™ C12059Lightlab Imaging, Inc. · WIRE, GUIDE, CATHETER1 death296 reports
- SYNCHRO 2 M00326410Stryker Corporation · WIRE, GUIDE, CATHETER2 recalls155 reports
- ENROUTE .014" Guidewire 11686-01Silk Road Medical, Inc. · Wire, Guide, Catheter2 deaths228 reports
- ARROW IPN035915Teleflex Incorporated · WIRE, GUIDE, CATHETER217 reports
- OmniWire Pressure guide wire 89185Philips Image Guided Therapy Corporation · Wire, Guide, Catheter1 recall1 death160 reports
- ARROW IPN055780Teleflex Incorporated · Wire, guide, catheter4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page