Esprit™ 1203250-28Recalls & reported problems

Abbott Vascular Inc. · Esprit™ BTK Everolimus Eluting Resorbable Scaffold System 2.50mm x 28mm Rapid-Exchange · Class 3 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08717648357237), received between Aug 1, 2024 and Jul 16, 2026 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Difficult to Advance” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Advance2
  • Improper or Incorrect Procedure or Method2
  • Ambient Temperature Problem1
  • Break1
  • Deformation Due to Compressive Stress1
  • Failure to Advance1
  • Material Too Rigid or Stiff1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 16, 2026Improper or Incorrect Procedure or Method; Difficult to Advance

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25846461 ↗
  • MalfunctionMar 2, 2026Improper or Incorrect Procedure or Method; Ambient Temperature Problem

    IT WAS REPORTED THAT THE PROCEDURE WAS TO TREAT THE RIGHT ANTERIOR TIBIAL ARTERY. THE 2.50 X 28 MM ESPRIT BTK SCAFFOLD WAS SUCCESSFULLY IMPLANTED. AFTER DEPLOYMENT, IT WAS OBSERVED THAT THE THERMOALERT TAG WAS NOTED TO BE TRIPPED. IT IS UNKNOWN WHEN THE TAG ALERT SENSOR WAS TRIGGERED AS THE DEVICE WAS NOT STORED IN A TEMPERATURE MONITORED ROOM. THERE WERE NO ADVERSE PATIENT EFFECTS AND NO CLINICALLY SIGNIFICANT DELAY IN THE PROCEDURE. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24491646 ↗
  • MalfunctionAug 1, 2024Break; Material Too Rigid or Stiff; Failure to Advance; Deformation Due to Compressive Stress; Difficult to Advance; Break; Material Too Rigid or Stiff; Failure to Advance; Deformation Due to Compressive Stress; Difficult to Advance

    IT WAS REPORTED THAT THE PROCEDURE WAS PERFORMED TO TREAT A LESION IN THE PERONEAL ARTERY WITH MODERATE CALCIFICATION AND MILD TORTUOSITY. A 6FR X 45 CM SHEATH AND A 0.014¿ NON-ABBOTT GUIDEWIRE WAS USED IN THE CASE. THE PHYSICIAN ACCESSED THE ANATOMY THROUGH THE RIGHT GROIN AND WENT UP AND OVER THE ILIAC ARCH TO THE LEFT SIDE. IVUS (INTRAVASCULAR ULTRASOUND) WAS USED TO VISUALIZE THE SUPERFICIAL FEMORAL ARTERY (SFA) AND A DRUG COATED BALLOON (DCB) WAS ADVANCED TO THE SFA. ANOTHER IVUS RUN WAS COMPLETED AFTER THE INFLATION OF THE DCB AND EVERYTHING LOOKED GOOD. THE TARGET LESION WAS IN THE PERONEAL ARTERY AND WAS PRE-DILATED WITH A BALLOON DILATATION CATHETER. THE ESPRIT BTK EVEROLIMUS ELUTING BIORESORBABLE SCAFFOLD SYSTEM WAS PREPPED AND INSERTED. THE PHYSICIAN COMMENTED THAT THE DEVICE FELT STIFF AND THERE WAS SOME RESISTANCE EXPERIENCED WHEN ADVANCING. THE DEVICE WAS ADVANCED UP AND OVER THE ILIAC ARCH, BUT ONCE ON THE OTHER SIDE, THERE WAS RESISTANCE AND THE DELIVERY SYSTEM WAS PUSHING THE SHEATH BACK TOWARDS THE AORTA. THE SDS WOULD NOT GO OVER THE ILIAC ARTERY. AFTER MULTIPLE ATTEMPTS, THE SDS WAS REMOVED FROM THE PATIENT WITHOUT ANY ISSUE. THE PROCEDURE WAS ENDED. WHEN THE SD

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19886947 ↗

Other Scaffold, Infrapopliteal, Absorbable devices