MYO/Wire® Ultra-Thin Temporary Pacing Wires BMZF605ACBBGRecalls & reported problems
A & E Medical Corporation · MYO/Wire® Ultra-Thin Bipolar Inline - 60cm - Blue - ZigZag/Flare 8mm electrode · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 08718627412527), received between Nov 18, 2022 and Jul 24, 2024 — classified as 2 injuries.
The most frequently reported specific device problem is “Material Frayed” (1 report).
1 other recall cover devices cleared under the same FDA submission (K033858); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Material Frayed1
- Pacing Problem1
Patient problems
- Cardiac Perforation1
- Ventricular Fibrillation1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJul 24, 2024Material Frayed; Material Frayed
IT WAS REPORTED THAT A CARDIAC PATIENT HAD TEMPORARY PACING WIRES PLACED IN THE OPERATING ROOM POST-OPERATIVELY. LATER AT NIGHT IT WAS DISCOVERED THAT THE PACING WIRE HAD FRAYED AND PIERCED THROUGH THE HEART WALL. THE PATIENT IS CURRENTLY IN STABLE CONDITION. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: Cardiac Perforation
MAUDE report 19819774 ↗InjuryNov 18, 2022Pacing Problem; Pacing Problem
IT WAS REPORTED THAT THE PACING WIRE THAT ATTACHES TO THE PATIENT'S HEART MALFUNCTIONED, RESULTING IN 3 EPISODES OF VENTRICULAR FIBRILLATION AFTER R ON T PHENOMENON. PATIENT REQUIRED CPR. PACING CABLE WAS SET AS A BACKUP RATE OF 50 WHILE THE PATIENT HAD HIS OWN RHYTHM OF 90. DESPITE THIS, THE PACER PACED THE PATIENT INAPPROPRIATELY AND CAUSED V-FIB. MILIAMPS WERE SET TO 10MA MILIVOLTS SET TO 2. IT WAS REPORTED THAT NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: Ventricular Fibrillation
MAUDE report 15824664 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K033858. One submission often covers many models, so check the product and lot details in each record.
- Z-1038-2012 · Apr 18, 2011 · TerminatedTemporary Pacing Wire, BIPOLAR, Models BM, V, VE and VF, Rx Only, STERILE/EO, Single use only -- Mce (MEDICAL CONCEPTS EUROPE) --- Manufacturer ECM B.V. Oost-Om 54, P.O. Box 53, NL
Other ELECTRODE, PACEMAKER, TEMPORARY devices
- N/A 006173PC. R. Bard, Inc. · ELECTRODE, PACEMAKER, TEMPORARY161 reports
- SWAN-GANZ D200F7Edwards Lifesciences LLC · ELECTRODE, PACEMAKER, TEMPORARY1 recall0 reports
- ETHICON TPW32Ethicon, LLC · ELECTRODE, PACEMAKER, TEMPORARY1 death46 reports
- ETHICON TPW20Ethicon, LLC · ELECTRODE, PACEMAKER, TEMPORARY39 reports
- N/A 520007PC. R. Bard, Inc. · ELECTRODE, PACEMAKER, TEMPORARY33 reports
- Pacel™ 401763St. Jude Medical Cardiovascular Division · ELECTRODE, PACEMAKER, TEMPORARY21 reports
- Pacel™ 401771St. Jude Medical Cardiovascular Division · ELECTRODE, PACEMAKER, TEMPORARY1 death16 reports
- SWAN-GANZ PACING TD CATHETER D205F7Edwards Lifesciences LLC · Electrode, Pacemaker, Temporary13 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page