Skip to content

INNOVERSE Spinal System NPA6545PRQRecalls & reported problems

CG MedTech Co.,Ltd. · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08800037596710), received between Sep 29, 2026 and Sep 29, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 29, 2026Detachment of Device or Device Component

    During a surgical procedure, while adjusting the position of the Rod, separation of the Screw from the Tulip (Head) of a Pedicle Screw occurred. No patient harm resulted from this event. The separated screw was removed and replaced with another screw, and the surgery was completed without further incident.A review of the production and inspection records for the separated POLYAXIAL RED. SCREW (QUAD), 6.5 x 45mm (Lot No. 24A15008), confirmed that raw materials meeting the required chemical composition and mechanical property specifications were used, and that the product's dimensions and appearance were manufactured in conformance with the design specifications. No other anomalies were identified in the production or inspection records.In this Pedicle Screw design, the Inner Cap inside the Tulip engages the head of the Screw to prevent it from disengaging. During Rod adjustment, if the Inner Cap becomes pinched at the top of the Tulip, a gap can form that allows the Collet portion of the Inner Cap to open wider than normal. This can allow the Screw head to pass through the widened Collet, resulting in separation of the Screw from the Tulip. However, once the Rod and Set Screw are pr

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50927670 ↗

Other Thoracolumbosacral pedicle screw system devices

All Thoracolumbosacral pedicle screw system devices →