INNOVERSE Spinal System NPA8570PSQRecalls & reported problems

CG MedTech Co.,Ltd. · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08800247364765), received between Mar 5, 2026 and Mar 5, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Structural Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Structural Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 5, 2026Structural Problem

    INITIAL SURGERY WAS PERFORMED ON (B)(6) 2025. DURING FOLLOW-UP EVALUATION, AN X-RAY TAKEN AROUND (B)(6) 2026 IDENTIFIED A FRACTURE AT THE NECK REGION OF THE ILIAC SCREW IMPLANTED AT THE S2 LEVEL. A REVISION SURGERY WAS PERFORMED ON(B)(6) 2026 TO REMOVE THE FRACTURED SCREW, AND THE IMPLANT WAS REPLACED. THE FRACTURED DEVICE WAS RETRIEVED, AND THE MANUFACTURING AND INSPECTION RECORDS FOR THE ASSOCIATED LOT WERE REVIEWED. THE INVOLVED DEVICE WAS POLYAXIAL STD. SCREW (QUAD) -8.5X70 MM (LOT NO. 24K22130). REVIEW OF MANUFACTURING AND INSPECTION RECORDS CONFIRMED THAT COMPLIANT RAW MATERIAL WITHIN THE REQUIRED CHEMICAL COMPOSITION AND MECHANICAL PROPERTY SPECIFICATIONS WAS USED, AND THAT THE DEVICE GEOMETRY, DIMENSIONS, AND VISUAL APPEARANCE MET APPLICABLE SPECIFICATIONS. THE DEVICE WAS DESIGNED TO MEET ASTM F1717 REQUIREMENTS CONSIDERING CLINICALLY RELEVANT LOADING CONDITIONS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24516102 ↗

Other Thoracolumbosacral pedicle screw system devices

All Thoracolumbosacral pedicle screw system devices →