RI.KNEE Tibia Fixation Base Right 4240-7502Recalls & reported problems

Enztec Limited · A reusable surgical instrument intended to be used during an orthopaedic surgical procedure · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 09421028118200), received between Nov 29, 2024 and Dec 27, 2024 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Separation Failure” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Separation Failure2
  • Fracture1
  • Mechanical Jam1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 27, 2024Separation Failure; Mechanical Jam; Separation Failure; Mechanical Jam

    IT WAS REPORTED THAT DURING CORI ASSISTED TKA SURGERY, THE SURGEON FIXATED A PIN INTO THE PIN HOLE OF THE RI. KNEE TIBIA FIXATION BASE RIGHT AND WHEN EXTRACTING THE PIN, THE PIN GOT STUCK AND THE HEAD OF THE PIN BROKE OFF WITHOUT EXCESSIVE FORCE WHICH CAUSED THE PIN TO GET STUCK IN THE HOLE, THE PIND DID NOT FRACTURE. THE DEVICE WAS BEING TAKEN OUT WHEN THE PIN GOT STUCK, THE DEVICE WAS NO LONGER NEEDED AND NO LONGER USED. SURGERY WAS RESUMED WITHOUT ANY DELAY. PATIENT IS HEALTHY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21026787 ↗
  • MalfunctionNov 29, 2024Fracture; Separation Failure; Fracture; Separation Failure

    IT WAS REPORTED THAT DURING A CORI ASSISTED TKA SURGERY; AFTER PREPPING THE FEMUR THE SURGEON WENT TO NAVIGATE THE TIBIA CUT. WHILE HE WAS TRYING TO RAISE THE ADJUSTABLE TIBIA GUIDE, THEY TURNED THE KNOB TO THE WRONG DIRECTION. THEY BOTTOMED OUT THE ADJUSTABLE TIBIA GUIDE AND KEPT TWISTING THE KNOB TO THE LEFT UNTIL THE KNOB BROKE OFF. NOW THE ADJUSTABLE TIBIA GUIDE AND THE FIXATION BASE ARE STUCK TOGETHER BECAUSE THE KNOB BROKE OFF. THE CASE WAS COMPLETED ROBOTICALLY, BUT THE SURGEON ENDED UP BURRING THE WHOLE TIBIA CUT INSTEAD OF NAVIGATING THE CUT WITH THE PLANE VISUALIZER. THE PROCEDURE WAS PERFORMED, AFTER A SIGNIFICANT DELAY, USING A S+N BACK-UP DEVICE. PATIENT WAS NOT HARMED AS CONSEQUENCE OF THIS PROBLEM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20808921 ↗