Medline Industries, Inc. DYND43075Recalls & reported problems
Medline Industries, Inc. · TUBE,ENDOTRACH,HVLP CUFF,MURPHY,7.5MM · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 11
- Deaths reported
- 1
- Injuries reported
- 7
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 10080196726325), received between Oct 31, 2018 and Sep 14, 2026 — classified as 1 death, 7 injuries, 3 malfunctions.
The most frequently reported specific device problem is “Gas/Air Leak” (3 reports).
1 other recall cover devices cleared under the same FDA submission (K042683); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Gas/Air Leak3
- Appropriate Device Problem Term/Code Not Available2
- Deflation Problem1
- Inflation Problem1
- Insufficient Device Problem Information1
- Material Too Rigid or Stiff1
- Obstruction of Flow1
- Particulates1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available3
- Insufficient Information2
- No Consequences Or Impact To Patient1
- Unspecified Respiratory Problem1
Recent adverse event reports
The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 14, 2026Deflation Problem; Obstruction of Flow
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50762982 ↗InjuryAug 13, 2024Gas/Air Leak; Gas/Air Leak
ACCORDING TO THE CUSTOMER, THE ENDOTRACHEAL TUBE PILOT BALLOON WAS "NOT INFLATING AND THE CUFF AT THE END IS NOT HOLDING PRESSURE" WHILE THE PATIENT WAS ON A VENTILATOR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19977198 ↗InjuryAug 12, 2024Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
ACCORDING TO THE FACILITY THE "PILOT BALLOON WOULD NOT REMAIN INFLATED."
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 19961699 ↗InjuryAug 12, 2024Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
ACCORDING TO THE FACILITY THE "PILOT BALLOON WOULD NOT REMAIN INFLATED".
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 19961047 ↗InjuryJun 24, 2024Insufficient Device Problem Information; Insufficient Device Problem Information
AFTER INSERTION OF THE TRACH TUBE, IT WAS NOTED THAT THE PATIENT WAS NOT RECEIVING TIDAL VOLUMES
Patient problems: Insufficient Information
MAUDE report 19598755 ↗InjuryJun 11, 2024Gas/Air Leak; Gas/Air Leak
ACCORDING TO THE CUSTOMER, THE PATIENT WAS REQUIRING INTUBATION DURING A "CODE BLUE" ON (B)(6) 2024 AND THE "ETT" CUFF WAS LEAKING.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19509932 ↗InjuryJan 30, 2024Material Too Rigid or Stiff; Material Too Rigid or Stiff
"THE TIP OF THE TUBE IS SHARP AND STIFF."
Patient problems: Insufficient Information
MAUDE report 18605466 ↗InjuryApr 25, 2023Pressure Problem; Pressure Problem
PILOT BALLOON NOT MAINTAINING PRESSURE.
Patient problems: Unspecified Respiratory Problem
MAUDE report 16808134 ↗MalfunctionJun 15, 2022Gas/Air Leak
IT WAS REPORTED THAT AT THE END OF THE PROCEDURE, WHEN THE PATIENT WAS ALREADY INTUBATED, THE FACILITY NOTICED A LOW RETURN VOLUME AND AN AUDIBLE CUFF LEAK REQUIRING RE-INTUBATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14696550 ↗DeathNov 16, 2021Inflation Problem
IT WAS REPORTED THAT DURING AN EMERGENT PLACEMENT (DURING AN IN-FLIGHT CARDIAC ARREST) A PATIENT WAS INTUBATED WITH A 7.5MM ENDOTRACHEAL TUBE. INTUBATION WAS COMPLETED AND THE CUFF WAS INFLATED WITH 7ML OF AIR. THE CREW NOTED THAT THE CUFF WOULD NOT STAY INFLATED, BOUGIE WAS PLACED AND THE TUBE WAS EXCHANGED SUCCESSFULLY HOWEVER THE PATIENT ULTIMATELY PASSED AWAY.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 12821827 ↗MalfunctionOct 31, 2018Particulates
IT WAS REPORTED THAT A PARTICULATE ORIGINATING FROM THE PACKAGING GOT INSIDE THE ENDOTRACHEAL TUBE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8023569 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K042683. One submission often covers many models, so check the product and lot details in each record.
- Z-3172-2026 · Jul 31, 2026 · Open, ClassifiedSunMed Tracheal Tube, Size 2.5; Model Number: 1-7333-25
Other Tube, tracheal (w/wo connector) devices
- Shiley 18875Covidien LP · Tube, tracheal (w/wo connector)4 deaths570 reports
- RUSCH IPN041476Teleflex Incorporated · Tube, tracheal (w/wo connector)10 recalls0 reports
- Shiley 18775Covidien LP · Tube, tracheal (w/wo connector)489 reports
- Shiley 18770Covidien LP · Tube, tracheal (w/wo connector)2 deaths434 reports
- Shiley 18880Covidien LP · Tube, tracheal (w/wo connector)2 deaths370 reports
- Shiley 18780Covidien LP · Tube, tracheal (w/wo connector)3 deaths286 reports
- Shiley 18770SCovidien LP · Tube, tracheal (w/wo connector)273 reports
- Shiley 18780SCovidien LP · Tube, tracheal (w/wo connector)251 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page