Infant Flow™ 7772020LPRecalls & reported problems

Vyaire Medical, Inc. · Infant Flow LP nCPAP Generator Set · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
8
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 10190752156531), received between Jan 6, 2023 and Jul 17, 2024 — classified as 8 injuries.

The most frequently reported specific device problem is “Material Integrity Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 3 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Integrity Problem3
  • Patient-Device Incompatibility3
  • Material Too Rigid or Stiff2
  • Partial Blockage1

Patient problems

  • Erythema3
  • No Clinical Signs, Symptoms or Conditions2
  • Skin Discoloration2
  • Skin Erosion2
  • Distress1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 17, 2024Patient-Device Incompatibility; Patient-Device Incompatibility

    IT WAS REPORTED TO VYAIRE MEDICAL THAT SKIN INTEGRITY OF INNER ASPECT NOSTRILS WAS DAMAGED FOLLOWING USE OF DEVICE. MODERATE ERYTHEMA AT INNER ASPECT OF NOSTRILS WAS REPORTED.

    Patient problems: Erythema

    MAUDE report 19763720 ↗
  • InjuryJul 17, 2024Patient-Device Incompatibility; Patient-Device Incompatibility

    IT WAS REPORTED TO VYAIRE MEDICAL THAT SKIN INTEGRITY OF NASAL SEPTUM DAMAGED FOLLOWING USE OF DEVICE. MODERATE ERYTHEMA AT BASE OF NASAL SEPTUM WAS REPORTED.

    Patient problems: Erythema

    MAUDE report 19763706 ↗
  • InjuryJul 17, 2024Patient-Device Incompatibility; Patient-Device Incompatibility

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE SKIN INTEGRITY OF THE NASAL SEPTUM WAS DAMAGED FOLLOWING USE OF DEVICE. PATIENT HARM WAS REPORTED: SKIN INTEGRITY OF NASAL SEPTUM BROKEN, ERYTHEMA PAIN, INFECTION REQUIRING ANTIBIOTIC THERAPY.

    Patient problems: Erythema

    MAUDE report 19763347 ↗
  • InjuryOct 10, 2023Partial Blockage; Material Integrity Problem; Partial Blockage; Material Integrity Problem

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE 7772020LP PACKAGE ASSEMBLY, INFANT FLOW, LP HAS EXCESSIVE RAIN DISCHARGE THAT FORMS WITHIN THE EXHAUST LIMB AND POOLS AT THE PATIENT INTERFACE, SIGNIFICANTLY IRRITATING NEONATAL PATIENTS AND POSING A SERIOUS RISK OF WATER ENTERING THE PATIENT'S AIRWAY. FURTHERMORE, THERE IS NO INFORMATION REGARDING PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17905700 ↗
  • InjuryAug 30, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE 7772020LP PACKAGE ASSEMBLY,INFANT FLOW,LP PLASTIC ASSEMBLY OF GENERATOR BROKE APART INTO 2 PIECES. IT WAS IN USE ON A PREMATURE BABY AND THE BABY'S VENTILATION WAS INTERRUPTED AND A NEW GENERATOR HAD TO BE CONNECTED TO FABIAN VENTILATOR AND ATTACHED TO HEADGEAR. WHICH RESULTED IN UNNECESSARY DISCOMFORT, BREATHING DIFFICULTY AND STRESS.

    Patient problems: Distress

    MAUDE report 17657780 ↗
  • InjuryAug 11, 2023Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE 7772020LP PACKAGE ASSEMBLY, INFANT FLOW, LP CAME APART WHILE CONNECTED TO A PATIENT. THEY HAD TO CHANGE THE WHOLE SET AS A RESULT. AT THIS TIME, THE CUSTOMER HAS NOT PROVIDED ANY INFORMATION REGARDING PATIENT HARM OR INJURY ASSOCIATED WITH THE REPORTED EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17506914 ↗
  • InjuryJan 6, 2023Material Too Rigid or Stiff; Material Too Rigid or Stiff

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE USE OF THE 7772020LP - PACKAGE ASSEMBLY, INFANT FLOW, LP NASAL PRONGS FOR CPAP (CONTINUOUS POSITIVE AIRWAY PRESSURE) RESULTED IN PRESSURE WOUNDS/RED MARKS ON THE PATIENT'S NOSE. ISSUE WAS QUICKLY IDENTIFIED, AND THE PRONGS WERE REPLACED BY A FACE MASK, AND THE REDDENED AREAS AT NARES EVENTUALLY IMPROVED. IT WAS STATED THAT THE NASAL PRONGS ARE NOT AS SOFT AS THE ONES FROM THEIR PREVIOUS SUPPLIER.

    Patient problems: Skin Discoloration; Skin Erosion

    MAUDE report 16114023 ↗
  • InjuryJan 6, 2023Material Too Rigid or Stiff; Material Too Rigid or Stiff

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE USE OF THE 7772020LP - PACKAGE ASSEMBLY,INFANT FLOW,LP NASAL PRONGS FOR CPAP (CONTINUOUS POSITIVE AIRWAY PRESSURE) RESULTED IN PRESSURE WOUNDS/RED MARKS ON THE PATIENT'S NOSE. ISSUE WAS QUICKLY IDENTIFIED, AND THE PRONGS WERE REPLACED BY A FACE MASK, AND THE REDDENED AREAS AT NARES EVENTUALLY IMPROVED. IT WAS STATED THAT THE NASAL PRONGS ARE NOT AS SOFT AS THE ONES FROM THEIR PREVIOUS SUPPLIER.

    Patient problems: Skin Discoloration; Skin Erosion

    MAUDE report 16112737 ↗

Other VENTILATOR, NON-CONTINUOUS (RESPIRATOR) devices

All VENTILATOR, NON-CONTINUOUS (RESPIRATOR) devices →