Skip to content

Medline SSN100257Recalls & reported problems

Medline Industries, Inc. · NEEDLE,HYPODERM,SAFETY, 25GX1.5 · Class 2

Adverse event reports
13
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 13 adverse event reports that list this exact device (DI 10193489031997), received between Mar 13, 2024 and Sep 30, 2026 — classified as 1 injury, 12 malfunctions.

The most frequently reported specific device problem is “Obstruction of Flow” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 10 reportsOct 2026: 0 reports20242025202610
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Obstruction of Flow3
  • Detachment of Device or Device Component2
  • Disconnection2
  • No Flow2
  • Connection Problem1
  • Entrapment of Device1
  • Fluid/Blood Leak1
  • Incomplete or Inadequate Connection1

Patient problems

  • No Clinical Signs, Symptoms or Conditions8
  • Foreign Body In Patient3
  • Device Embedded In Tissue or Plaque1
  • Needle Stick/Puncture1
  • Skin Tears1

Recent adverse event reports

The 13 most recent of 13 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 30, 2026Obstruction of Flow

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50949703 ↗
  • MalfunctionSep 28, 2026Obstruction of Flow

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50921975 ↗
  • MalfunctionSep 24, 2026Entrapment of Device; Detachment of Device or Device Component

    It was reported that "when injecting into patients arms it is tearing the skin. Another instance is the needle got stock in a patient arm as well I was told".

    Patient problems: Foreign Body In Patient; Skin Tears

    MAUDE report 50885134 ↗
  • MalfunctionSep 24, 2026Obstruction of Flow

    This VMSR report summarizes approximately 10 malfunction events that occurred during Q3 2025 (July 1, 2025 through September 30, 2025). The account reported that injections were interrupted because the medication stopped dispensing mid-injection when using the affected product. The customer indicated that the issue was observed across four different lots and had occurred with approximately ten patients. The product was reportedly used with Kenalog and lidocaine administered via a 3 mL syringe. The reported malfunction resulted in incomplete delivery of medication during injection procedures. Samples were returned for evaluation under a related complaint, and additional complaint records were opened to document the affected lots. No serious injuries were reported.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50882107 ↗
  • MalfunctionSep 18, 2026Disconnection; Fluid/Blood Leak

    It was reported that "It was happening with our pre-drawn influenza vaccines and was leaking from the luer connector" and "One needle detached and was left in a patient's arm."

    Patient problems: Foreign Body In Patient

    MAUDE report 50817818 ↗
  • MalfunctionSep 15, 2026Incomplete or Inadequate Connection

    It was reported that "The Luer Lok function on these needles does not work 100% of the time" and "This has led to the needle remaining in our patients after injecting medication because the needle device un-screws from the syringe."

    Patient problems: Foreign Body In Patient

    MAUDE report 50773189 ↗
  • MalfunctionSep 13, 2026Disconnection

    Patient problems: Needle Stick/Puncture

    MAUDE report 50746954 ↗
  • MalfunctionSep 9, 2026Loose or Intermittent Connection; Material Twisted/Bent

    It was reported that "The needles bend easily and the orange safety piece is \"loose.\" It does not stay in place." It was also reported that "When the needle is attached to a syringe and the surgeon goes to inject local, the safety piece falls forward making in possible to advance the needle without putting your finger by the needle to pull/hold back the safety piece."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50694834 ↗
  • MalfunctionSep 9, 2026No Flow

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50690438 ↗
  • MalfunctionSep 8, 2026No Flow

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50677347 ↗
  • InjuryOct 30, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    ACCORDING TO THE FACILITY ON 9/30, "I WAS TRYING TO ADMINISTER A FLULAVAL VACCINE. I SECURED THE MEDLINE 25G, 1.5" SURE-SNAP SAFETY NEEDLE TO THE PRE-FILLED SYRINGE, AS IS TYPICAL FOR VACCINE ADMINISTRATION, AND WENT TO ADMINISTER THE VACCINE. AS I PRESSED IN THE PLUNGER OF THE SYRINGE, THE NEEDLE DETACHED FROM THE SYRINGE AND THE VACCINE WASTED OUTSIDE OF THE PATIENT'S SHOULDER.".

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 20569756 ↗
  • MalfunctionJun 4, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    THE NEEDLE COMES OUT OF THE SYRINGE WHEN PERFORMING INJECTIONS AND STAYED IN THE PATIENT SKIN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19465086 ↗
  • MalfunctionMar 13, 2024Connection Problem; Connection Problem

    NEEDLE CAME OFF SYRINGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18893849 ↗

Other Syringe, piston devices

All Syringe, piston devices →