Portex 505080Recalls & reported problems
Icu Medical, Inc. · Class 2
All models of Portex (409)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10351688021007), received between Jul 24, 2019 and Mar 18, 2021 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Contamination” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K934465); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Contamination1
- Gas/Air Leak1
- Residue After Decontamination1
Patient problems
- Airway Obstruction1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 18, 2021Gas/Air Leak; Gas/Air Leak
MalfunctionJul 24, 2019Contamination; Residue After Decontamination; Contamination; Residue After Decontamination
INFORMATION WAS RECEIVED THAT A SMITHS MEDICAL PORTEX CUFFED FLEX D.I.C TRACHEOSTOMY TUBE PILOT BALLOON WAS BLACK ON THE INSIDE AND SLIGHTLY WENT UP THE TUBE. THE ISSUE WAS DISCOVERED UPON CLEANING. IT WAS ALSO REPORTED THE PATIENT WAS STILL USING THE DEVICE UNTIL A ROUTINE TRACHEOSTOMY CHANGE OUT WAS PERFORMED. THERE WERE NO ADVERSE PATIENT EFFECTS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8822325 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K934465. One submission often covers many models, so check the product and lot details in each record.
Other Tube, tracheal (w/wo connector) devices
- Shiley 18875Covidien LP · Tube, tracheal (w/wo connector)4 deaths570 reports
- RUSCH IPN041476Teleflex Incorporated · Tube, tracheal (w/wo connector)10 recalls0 reports
- Shiley 18775Covidien LP · Tube, tracheal (w/wo connector)489 reports
- Shiley 18770Covidien LP · Tube, tracheal (w/wo connector)2 deaths434 reports
- Shiley 18880Covidien LP · Tube, tracheal (w/wo connector)2 deaths370 reports
- Shiley 18780Covidien LP · Tube, tracheal (w/wo connector)3 deaths286 reports
- Shiley 18770SCovidien LP · Tube, tracheal (w/wo connector)273 reports
- Shiley 18780SCovidien LP · Tube, tracheal (w/wo connector)251 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page