Icu Medical, Inc. · Class 2

All models of Medex (98)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10351688504159), received between Aug 1, 2017 and Sep 9, 2022 — classified as 2 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Blocked Connection” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Blocked Connection1
  • Break1
  • Crack1
  • Leak/Splash1
  • Material Fragmentation1
  • Obstruction of Flow1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Low Blood Pressure/ Hypotension1
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 9, 2022Blocked Connection; Blocked Connection

    IT WAS REPORTED THAT DURING USE, THE DEVICE WAS BLOCKED AND USE WAS DISCONTINUED. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15396837 ↗
  • MalfunctionMar 4, 2022Obstruction of Flow; Obstruction of Flow

    IT WAS REPORTED THAT DEBRIS WAS FOUND IN LINE WHILE CONNECTED TO PATIENT. MANIFOLD AND ALL TUBING CHANGED OUT. BLOOD HAD BACKED UP INTO TUBING. THERE WAS NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13666987 ↗
  • InjuryMay 22, 2020Break; Material Fragmentation; Break; Material Fragmentation

    INFORMATION WAS RECEIVED INDICATING THAT A SMITHS MEDICAL MEDEX MANIFOLD SNAPPED AT THE CONNECTION PIECE. THE PATIENT WAS REPORTED TO BE RECEIVING VASOPRESSORS AT THE TIME OF BREAK LEADING TO THE PATIENT BECOMING HYPOTENSIVE. TITRATION OF VASOPRESSORS WAS INCREASED TO ACHIEVE THE ORDERED MEAN ARTERIAL PRESSURE (MAP) GOALS. THE UNIT WAS CHANGED OUT AND DISCARDED WITH NO FURTHER REPORTED ADVERSE EFFECTS.

    Patient problems: Low Blood Pressure/ Hypotension

    MAUDE report 10082937 ↗
  • InjuryAug 1, 2017Crack; Leak/Splash; Crack; Leak/Splash

    IT WAS REPORTED THAT A MEDEX¿ LARGE BORE - HI-FLO¿ STOPCOCK LEAKED AND CRACKED WHEN NURSES HOOKED UP THE INTRAVENOUS TUBING. THE PRODUCT FAULT OCCURRED WHILE IN USE WITH A PATIENT. PATIENT RECEIVED A BOLUS OF PRESSORS TO IMPROVE BLOOD PRESSURE DUE TO THE INTERRUPTIONS IN THERAPY. NO PERMANENT INJURY WAS REPORTED, AND THE OUTCOME OF THE EVENT WAS REPORTED AS RESOLVED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6758112 ↗

Other Stopcock, i.V. Set devices

All Stopcock, i.V. Set devices →