Integra® Jarit® P6845TCRecalls & reported problems
Integra Lifesciences Production Corporation · Integra® Jarit® Reynolds Scissors, 5-1/8", Tungsten Carbide Supercut, Curved, Semi-Sharp · Class 1
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10381780220596), received between Jun 10, 2021 and Jun 10, 2021 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Material Fragmentation” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Material Fragmentation2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 10, 2021Material Fragmentation; Material Fragmentation
THIS IS #2 OF 2 REPORTS FOR TWO IDENTICAL DEVICES AND EVENTS. THE FACILITY REPORTED THAT WHEN THE SURGEON WAS DISSECTING TISSUE ON PATIENT NUMBER 2, THE TIP OF REYNOLD SCISSORS NUMBER 2 BROKE ON ONE SIDE OF THE JAW AND FELL INTO THE SURGICAL SITE. ALL THE BROKEN PARTS WERE RECOVERED AND THE FIELD WAS IRRIGATED THOROUGHLY. SUBSEQUENTLY, ANOTHER INSTRUMENT ON THE TRAY IN THE ROOM WAS USED. THERE WAS NO PATIENT INJURY AND NO DELAY IN SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11972796 ↗MalfunctionJun 10, 2021Material Fragmentation; Material Fragmentation
THIS IS #1 OF 2 REPORTS FOR TWO IDENTICAL DEVICES AND EVENTS. THE FACILITY REPORTED THAT WHEN THE SURGEON WAS DISSECTING TISSUE ON PATIENT NUMBER 1, THE TIP OF REYNOLD SCISSORS NUMBER 1 BROKE ON ONE SIDE OF THE JAW AND FELL INTO THE SURGICAL SITE. ALL THE BROKEN PARTS WERE RECOVERED AND THE FIELD WAS IRRIGATED THOROUGHLY. SUBSEQUENTLY, ANOTHER INSTRUMENT ON THE TRAY IN THE ROOM WAS USED. THERE WAS NO PATIENT INJURY AND NO DELAY IN SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11972764 ↗
Other SCISSORS, GENERAL, SURGICAL devices
- MEDLINE DYNJ04049Medline Industries, Inc. · SCISSORS, GENERAL, SURGICAL3 recalls2 reports
- MEDLINE DYND04000Medline Industries, Inc. · SCISSORS, GENERAL, SURGICAL3 recalls0 reports
- Centurion 66155Centurion Medical Products Corporation · SCISSORS, GENERAL, SURGICAL1 recall1 report
- Centurion I68790Centurion Medical Products Corporation · SCISSORS, GENERAL, SURGICAL1 recall0 reports
- Centurion 66150Centurion Medical Products Corporation · SCISSORS, GENERAL, SURGICAL1 recall0 reports
- Centurion 66350Centurion Medical Products Corporation · SCISSORS, GENERAL, SURGICAL1 recall0 reports
- Centurion 67645Centurion Medical Products Corporation · SCISSORS, GENERAL, SURGICAL1 recall0 reports
- Centurion 66710Centurion Medical Products Corporation · SCISSORS, GENERAL, SURGICAL1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page