Licox® IP2PRecalls & reported problems

Integra LifeSciences Switzerland Sàrl · Licox® Brain Tissue Oxygen Monitoring- Complete Brain Probe Kit · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 10381780250333), received between Feb 3, 2022 and Oct 17, 2025 — classified as 3 injuries, 4 malfunctions.

The most frequently reported specific device problem is “Device-Device Incompatibility” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 2 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 2 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device-Device Incompatibility3
  • Incorrect Measurement2
  • Blocked Connection1
  • Difficult to Advance1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Hematoma2
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Insufficient Information1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 17, 2025Blocked Connection; Blocked Connection

    A FACILITY REPORTED THAT THE "KIT CONTAINING CC1.P1 AND THE IP2 INTRODUCER (IP2P)" WAS INSERTED ON THURSDAY, APRIL 10TH AND ON APRIL 12TH, PBO2 STARTED TO READ 500 AND CONTINUED TO DO SO. TEMPERATURE CONTINUES TO READ AT NORMAL PATIENT BASELINE VALUES, AND A CT SCAN WAS COMPLETED TO VERIFY PROBE PLACEMENT. A NEW MACHINE AND CABLE HAS BEEN SWITCHED OUT AND CONTINUED TO READ PBO2 AT 500. ADDITIONAL INFORMATION RECEIVED AS FOLLOWS: 1. WHAT TYPE OF PROCEDURE WAS PERFORMED? ANSWER: INSERTION OF LICOX, AFTER A FEW DAYS THE PBT02 BEGAN READING FALSELY HIGH NUMBERS. THE AVERAGE NUMBER WAS 500. 2. WAS THERE A DELAY IN SURGERY DUE TO PRODUCT PROBLEM? IF YES, HOW LONG WAS THE SURGICAL DELAY IN MINUTES? ANSWER: NO 3. HAS THE PROBE ALREADY REMOVED? IF YES, PLEASE PROVIDE DATE OF EXPLANTATION. ANSWER: NO 4. HOW WAS THE PATIENT MONITORED WHEN THE VALUES WERE INACCURATE? ANSWER: A CERELINK CATHETER WAS ALSO INSITU. WE CONTINUED TO MONITOR CLINICALLY AND IGNORED THE PBT02 VALUES 5. PLEASE CONFIRM IF THERE WAS ANOTHER PROBE INSERTED? ANSWER: YES A CERELINK CATHETER WAS INSITU 6. PATIENT OUTCOME/STATUS: ANSWER: REMAINS ADMITTED IN ICU.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23325103 ↗
  • InjuryAug 10, 2024Incorrect Measurement; Incorrect Measurement

    N/A.

    Patient problems: Hematoma

    MAUDE report 19957456 ↗
  • InjuryAug 10, 2024Incorrect Measurement; Incorrect Measurement

    THIS REPORT IS 3 OF 3 FOR THE 1ST LICOX PROBE IMPLANTED, AND IS LINKED TO MFG REPORT NUMBERS 3006697299-2024-00118 AND 3013886523-2024-00243: A FACILITY REPORTED THAT AFTER IMPLANTATION INVOLVING THE "KIT CONTAINING CC1.P1 AND THE IP2 INTRODUCER (IP2P)", THE VALUE REMAINED LOW AT 1-3 MMHG, NON-VARIABLE WITH A NEGATIVE FIO2 TEST. THE CT SCAN SHOWED A GOOD IMPLANTATION; HOWEVER, THE DAY AFTER ITS IMPLEMENTATION, THE TEMPERATURE SHOWED IMPROBABLE VALUES. ADDITIONAL INFORMATION RECEIVED AS FOLLOWS: DATE OF IMPLEMENTATION: (B)(6) 2024. DATE OF EXPLANTING: (B)(6) 2024. HAS ANOTHER CATHETER BEEN INSERTED? YES, THE (B)(6) 2024. HOW WAS THE PATIENT FOLLOWED UP WHEN THE VALUES WERE INACCURATE? EMPIRIC MANAGEMENT AND CONTROL BY CT SCANNER AND INFUSION. DECISION TO REPLACE ONE ON THIS BASIS ON 16 JULY. COMPLICATED PLACEMENT OF A SMALL EXTRA-SUBDURAL HEMATOMA. 2ND IMPLANTATION OF 16 JULY WITH HEMATOMA. 2ND PROBE WAS INDEED A LICOX. IT WORKED WELL BUT AFTER DELAY WITH LOW INITIAL VALUES AND LOW REACTIVITY AT FIO2 INCREASE. THE HEMATOMA WAS SECONDARY TO THE INSERTION OF THE PROBE. DID THE ISSUE(S) WITH THE PRODUCT ARISE BEFORE A SURGERY (PATIENT PREPARED/UNDER ANESTHESIA)? DURING SURGERY? WHEN FI

    Patient problems: Insufficient Information

    MAUDE report 19957455 ↗
  • MalfunctionMar 8, 2024Device-Device Incompatibility; Device-Device Incompatibility

    N/A.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18871685 ↗
  • MalfunctionMar 8, 2024Device-Device Incompatibility; Device-Device Incompatibility

    N/A.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18871671 ↗
  • MalfunctionFeb 22, 2024Device-Device Incompatibility; Device-Device Incompatibility

    N/A.

    Patient problems: Hematoma

    MAUDE report 18764504 ↗
  • InjuryFeb 3, 2022Difficult to Advance; Difficult to Advance

    A FACILITY REPORTED THAT THE COMPLETE BRAIN PROBE (P2PEU) DID NOT PASS THE PATIENT'S DURA MATER BUT "PUSH IT FORWARD." THE ISSUE LED TO AN AIR COLLECTION BETWEEN THE SKULL AND DURA (THE PROBE SEEMED TO HAVE PUSHED THE DURA FORWARD INSTEAD OF PASSING THROUGH IT). THERE WAS NO BLEEDING OR CONTUSIONS AND THE AIR COLLECTION HAD ALMOST FULLY RESOLVED (AS CHECKED ON CT SCAN OF THE BRAIN) ONCE THE BOLT/PROBE WAS REMOVED AND A NEW ONE PLACED ON THE CONTRALATERAL SIDE. A SINGLE LUMEN BOLT AND ICP PROBE FROM CAMINO WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO FURTHER PATIENT CONSEQUENCE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 13443690 ↗

Other DEVICE, MONITORING, INTRACRANIAL PRESSURE devices