Integra® Jarit® 100262Recalls & reported problems

Integra Lifesciences Production Corporation · Integra® Jarit® Metzenbaum Scissors, 7", Curved · Class 1

All models of Integra Jarit (57)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10381780432517), received between Feb 9, 2022 and Jul 10, 2026 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Mechanical Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 10, 2026Break

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25779680 ↗
  • MalfunctionFeb 9, 2022Break; Mechanical Problem; Break; Mechanical Problem

    A FACILITY REPORTED THAT THE CURVED METZENBAUM SUPERCUT SCISSOR (102122) BROKE DURING A CASE FOR KNEE ARTHROSCOPY WITH MULTIPLE LIGAMENT REPAIRS WITH ALLOGRAFTS. WHILE CUTTING SOFT TISSUE, THE SHAFT OF THE HANDLE NEAR THE LOCKBOX BROKE AND FLEW BACK, AND NEARLY HIT THE SURGEON IN THE FACE. THE STAFF IRRIGATED HEAVILY TO MAKE SURE ALL SMALL PIECES WERE REMOVED. IT WAS REPORTED THAT NO PART OF THE INSTRUMENT FELL INTO THE SURGICAL SITE THAT COULD BE SEEN WITH THE NORMAL EYE. AN X-RAY WAS PERFORMED MULTIPLE TIMES. THERE WAS A SURGICAL DELAY OF 30 MINUTES, AS THE STAFF HAD TO STOP TO ADDRESS THE ISSUE. THE NURSE OBTAINED ANOTHER PAIR OF METZENBAUM SCISSOR. IT WAS REPORTED THAT THE PATIENT'S OUTCOME WAS GREAT, ALTHOUGH PATIENT HAD TO ENDURE EXTRA MINUTES OF ANESTHESIA AND MORE DOSES OF RADIATION THAT WAS PLANNED FOR.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13498296 ↗