Skip to content

CUSA® Clarity C7523Recalls & reported problems

Integra Lifesciences (Ireland) Limited · CUSA® Clarity Nosecone · Class U

All models of CUSA Clarity (21)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10381780466215), received between May 9, 2024 and May 9, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Premature Activation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Premature Activation1

Patient problems

  • Burn(s)1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 9, 2024Premature Activation; Premature Activation

    A FACILITY REPORTED THAT THE THE CUSA CLARITY 23KHZ CEM NOSECONE (C7523 WAS USED IN A LAPAROSCOPIC HEPATECTOMY PROCEDURE, AND 30 MINUTES AFTER LIVER SECTION STARTED, THE DEVICE TURNED ON EVEN THOUGH THE BUTTON ON THE CEM NOSECONE WAS NOT PRESSED. THE PATIENT¿S SKIN GOT BURNED APPROXIMATELY 1CM IN DIAMETER, SINCE THE DEVICE WAS PLACED RIGHT UNDER A PORT. THE SURGEON STOPPED USING THE DEVICE AND THE PROCEDURE WAS COMPLETED USING A STANDARD NOSECONE. ACCORDING TO FURTHER INVESTIGATION, ONE OF THE CONNECTOR PINS WAS MISSING AND THE MISSING PIN WAS NOT RETURNED. ACCORDING TO THE SALES REP, THE PIN WAS REMOVED AT THE HOSPITAL. THE GENERATOR THAT WAS USED WITH THE PRODUCT WAS ZERUK / MERA.

    Patient problems: Burn(s)

    MAUDE report 19282657 ↗

Other Device, neurosurgical fragmentation and aspiration devices

All Device, neurosurgical fragmentation and aspiration devices →

Sources and updates