Integra® DuraFlex® BP10405Recalls & reported problems
Integra Lifesciences Corporation · Integra® DuraFlex™ Suturable Dural Graft 4 cm x 5 cm · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10381780511342), received between Mar 18, 2021 and Mar 18, 2021 — classified as 1 injury.
The most frequently reported specific device problem is “Material Puncture/Hole” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Puncture/Hole1
Patient problems
- Cerebrospinal Fluid Leakage1
- Purulent Discharge1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 18, 2021Material Puncture/Hole; Material Puncture/Hole
IT WAS REPORTED THAT A PATIENT WITH CHIARI MALFORMATION UNDERWENT A SURGICAL PROCEDURE ON (B)(6) 2020 WITH IMPLANTATION OF AN RTI SURGICAL, INC. DURAFLEX SUTURABLE GRAFT. THE FIRST WEEK OF (B)(6) 2021, THE PATIENT DEVELOPED A CEREBROSPINAL FLUID (CSF) LEAK. ON (B)(6) 2021, THE GRAFT WAS RESUTURED AND AUGMENTED WITH MUSCLE. TWO DAYS POST-OPERATIVELY, A CSF LEAK DEVELOPED AND A LUMBAR DRAINED WAS PLACED FOR 5 DAYS. ANOTHER CSF LEAK DEVELOPED AND VP SHUNT WAS PLACED ON (B)(6) 2021. ON (B)(6) 2021, THE PATIENT HAD PURULENT CSF DRAINAGE. ON (B)(6) 2021, THE PHYSICIAN PERFORMED A RE-EXPLORATION OF THE SUBOCCIPITAL WOUND WITH REMOVAL OF THE GRAFT, VP SHUNT AND IMPLANT OF NEW GRAFT (UNKNOWN) AND PLACEMENT OF AN EXTERNAL VENTRICULAR CSF DRAIN. THE EXPLANTED DURAFLEX GRAFT WAS DESCRIBED AS HAVING A 1.5CM HOLE IN THE CENTER, THE GRAFT WAS ADHERENT TO PARENCHYMA. TO DATE, REQUESTED ADDITIONAL INFORMATION HAS NOT BEEN PROVIDED.
Patient problems: Cerebrospinal Fluid Leakage; Purulent Discharge
MAUDE report 11516068 ↗
Other DURA SUBSTITUTE devices
- Durepair® 62100Medtronic Ps Medical, Inc. · DURA SUBSTITUTE1 recall6 reports
- Durepair® 62105Medtronic Ps Medical, Inc. · DURA SUBSTITUTE1 recall5 reports
- DuraMatrix Onlay CDSLM45Collagen Matrix, Inc. · Dura Substitute1 recall3 reports
- Durepair® 62110Medtronic Ps Medical, Inc. · DURA SUBSTITUTE1 recall3 reports
- Durepair® 62111Medtronic Ps Medical, Inc. · DURA SUBSTITUTE1 recall1 report
- Durepair® 62106Medtronic Ps Medical, Inc. · DURA SUBSTITUTE1 recall1 report
- Durepair® 62158Medtronic Ps Medical, Inc. · DURA SUBSTITUTE1 recall0 reports
- Biodesign G31091Cook Biotech Incorporated · DURA SUBSTITUTE1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page