DirectLink™ 826828Recalls & reported problems

Integra LifeSciences Switzerland Sàrl · DirectLink™ ICP Module · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
11
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 10381780515784), received between Apr 6, 2022 and Oct 10, 2025 — classified as 3 injuries, 8 malfunctions.

The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Incorrect, Inadequate or Imprecise Result or Readings4
  • Incorrect Measurement2
  • Low Readings2
  • Appropriate Device Problem Term/Code Not Available1
  • Connection Problem1
  • Output Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7
  • Insufficient Information4

Recent adverse event reports

The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 10, 2025Incorrect Measurement; Incorrect Measurement

    N/A.

    Patient problems: Insufficient Information

    MAUDE report 23266825 ↗
  • MalfunctionJan 28, 2025Connection Problem; Connection Problem

    2 OF 2 REPORTS. OTHER MFG REPORT NUMBER: 3013886523-2025-00018. A FACILITY REPORTED A MICROSENSOR BASIC KIT (ID: 626631) WAS PLACED IN THE OPERATIVE ROOM, THE PATIENT WAS TRANSFERRED TO THE INTENSIVE CARE UNIT (ICU). THE ICU STAFF WAS NEVER ABLE TO RETRIEVE DATA. THE DIRECT LINK MONITOR (UNKNOWN ID) AND SENSOR NEVER DISPLAYED A GREEN ACTIVE LIGHT AND THE CONNECTION TO THE PATIENT MONITOR WAS NOT SHOWING UP EITHER. NO ACTIVITY FROM THE SENSOR VIA THE DIRECTLINK AND PATIENT MONITOR, THEREFORE, THE SENSOR WAS EXPLANTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21254401 ↗
  • MalfunctionJan 31, 2024Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    N/A.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18619284 ↗
  • InjuryNov 28, 2023Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    1 OF 5 REPORTS. OTHER MFG REPORT NUMBERS: 3013886523-2023-00424, 3013886523-2023-00426, 3013886523-2023-00428, 3013886523-2023-00427. A FACILITY REPORTED: THE WHOLE PROCEDURE FROM CALIBRATION DIRECKTLINK TO THE MONITOR, THE ZEROING FROM THE SENSOR AND IMPLEMENTATION WENT WELL. NO ORANGE OR RED LIGHT ON THE DIRECTLINK. BUT AFTER PLACING THE FIRST SENSOR AFTER 6 HOURS ICP FLUCTUATION (HERE WAS THE SCREW LUXATED) AND THEN PLACED 3 SENSORS AGAIN, ALSO WITH FLUCTUATIONS IN VERY HIGH ICP, LOW ICP AND ALSO A FLAT LINE. IT WAS A VERY COMPLEX TRAUMA PATIENT. NO ADDITIONAL INFORMATION HAS BEEN PROVIDED.

    Patient problems: Insufficient Information

    MAUDE report 18222031 ↗
  • MalfunctionAug 15, 2023Output Problem; Output Problem

    N/A.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17549611 ↗
  • MalfunctionJan 13, 2023Incorrect Measurement; Incorrect Measurement

    OTHER MFG REPORT NUMBER: 3013886523-2022-00599. A FACILITY REPORTED NEGATIVE VALUES OF A CERELINK MICROSENSOR (ID 826851). THE SENSOR WAS USED WITH DIRECTLINK ICP MODULE (ID 826828). MONITORING WAS NOT POSSIBLE, THEREFORE, SENSOR WAS EXPLANTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16158899 ↗
  • InjuryJan 4, 2023Low Readings; Low Readings

    2 OF 2 REPORTS. OTHER MFG REPORT NUMBER: 3013886523-2022-00591. A FACILITY REPORTED A CERELINK SENSOR WAS IMPLANTED, THE VALUES WERE STABLE FOR ONE DAY UNTIL SUDDENLY DROPPED TO NEGATIVE NUMBERS. THE SENSOR AND THE DIRECTLINK MONITOR WERE REPLACED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16096243 ↗
  • MalfunctionNov 8, 2022Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    N/A.

    Patient problems: Insufficient Information

    MAUDE report 15753542 ↗
  • MalfunctionNov 8, 2022Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    N/A

    Patient problems: Insufficient Information

    MAUDE report 15753428 ↗
  • InjuryMay 24, 2022Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    2 OF 3 REPORTS. OTHER MFG REPORT NUMBERS: 3013886523-2022-00211 AND 3013886523-2022-00214. A FACILITY REPORTED THE PROCEDURE OF THE INSERTION OF THE PIC WENT WITHOUT COMPLICATIONS. DEVICE WORK ASK EXPECTED FOR 3 HOURS, THEN THE INTRACRANIAL PRESSURE WENT FROM 6 MMHG TO THE BOTTOM OF THE SCALE. NO PATIENT MOVEMENT OR DEVICE MANIPULATION OCCURRED. THE INSERTION OF THE NEW DEVICE WAS PERFORMED CHANGING ALSO THE MONITOR CABLE, THE JUNCTION BOX AND THE CONNECTION CABLE-DEVICE. THE DEVICE WAS USED IN A 47 YEAR-OLD FEMALE PATIENT FOR MONITORING AND CONTROLLING INTRACRANIAL PRESSURE IN A PATIENT WITH SEVERE HEAD INJURY/TRAUMA.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14489389 ↗
  • MalfunctionApr 6, 2022Low Readings; Low Readings

    2 OF 2 REPORTS. OTHER MFG REPORT NUMBER: 3013886523-2022-00135. A FACILITY REPORTED A DIRECTLINK ICP MODULE WAS SHOWING NEGATIVE READINGS AFTER IMPLANTATION. THE SENSOR WAS REPLACED AND ONE HOUR SURGICAL DELAY WAS REPORTED BECAUSE WHEN THE SENSOR WAS REPLACED, THE NEGATIVE READINGS PERSISTED; THEREFORE, THE SENSORS WERE NOT THE CAUSE. THE MONITORING CONTINUED WITH A COMPETITOR MODULE AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14021219 ↗

Other Device, monitoring, intracranial pressure devices

All Device, monitoring, intracranial pressure devices →