CODMAN® IPC EXPRESS® 826636Recalls & reported problems

Integra Lifesciences Production Corporation · CODMAN® IPC EXPRESS® CABLE · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10381780520481), received between Apr 5, 2024 and Mar 21, 2025 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Incorrect Measurement” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 2 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Incorrect Measurement2
  • Electrical Shorting1

Patient problems

  • Cerebral Edema2
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 21, 2025Incorrect Measurement; Incorrect Measurement

    N/A.

    Patient problems: Cerebral Edema

    MAUDE report 21664254 ↗
  • MalfunctionMar 21, 2025Incorrect Measurement; Incorrect Measurement

    1 OF 3 REPORTS: OTHER MFG REPORT NUMBERS: 3014334038-2025-00040, 3013886523-2025-00055. A FACILITY REPORTED: "CODMAN MEASUREMENT DOES NOT WORK. MUST BE RESET MULTIPLE TIMES. PATIENT CRITICALLY ILL WITH LABILE ICP WITHOUT POSSIBILITY OF MEASUREMENT ON EVD. CODMAN CHANGED X 3 DURING DAY SHIFT AND BEGINNING OF EVENING SHIFT. MEASUREMENT IS SEEN AT ONE POINT ON CODMAN BUT CANNOT BE DISPLAYED ON SCREEN." "FINALLY, WITH THE HELP OF THE ANESTHESIA NURSE (FETCHED SEVERAL CODMAN) IT IS POSSIBLE TO GET THE CORRECT MEASUREMENTS. DURING SHIFT, PATIENT HAS DEVELOPED PUPIL DIFF DUE TO INCREASING EDEMA AND CODMAN HAS NOT SHOWN CORRECT MEASUREMENT. NEITHER ON CODMAN NOR SCREEN." PATIENT WAS URGENTLY TAKEN TO THE OPERATING ROOM FOR EVD PLACEMENT. CONSEQUENCE OF THE INCIDENT: MEDICAL OR SURGICAL TREATMENT WERE OTHER MEDICAL DEVICES USED IN CONNECTION WITH THE INCIDENT (E.G. ACCESSORIES)? YES. SEVERAL SERIAL NUMBERS IN USE IN THE DEPARTMENT: (B)(6), ETC. CABLES TO AND FROM THE ICP ELECTRODE IN THE BRAIN AND THE ONE OUT TO THE SCREEN CAN BE REPLACED BETWEEN THE DIFFERENT ICP MONITORS. ICP SENSOR (THE ELECTRODE IN THE BRAIN) THAT CONNECT TO THE ICP MONITOR: CERELINK (TM) ICP SENSOR, REFERENCE NUMBER: (

    Patient problems: Cerebral Edema

    MAUDE report 21664252 ↗
  • MalfunctionApr 5, 2024Electrical Shorting; Electrical Shorting

    N/A.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19054540 ↗

Other Device, monitoring, intracranial pressure devices

All Device, monitoring, intracranial pressure devices →