GLOBAL UNITE 1100-56-510Recalls & reported problems
Depuy (Ireland) · GLOBAL UNITE STANDARD HUMERAL HEAD SIZE 56mm x 18mm · Class 2 · Implant
All models of GLOBAL UNITE (91)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10603295004752), received between Feb 28, 2019 and Mar 26, 2026 — classified as 2 injuries.
8 other recalls cover devices cleared under the same FDA submission (K101996, K170748); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Arthritis1
- Discomfort1
- No Code Available1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMar 26, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT PATIENT HAS A GLOBAL AP HEMI IMPLANTED FROM OVER 10 YEARS AGO. PATIENT HAS DEVELOPED ARTHRITIS ON THE GLENOID SIDE AND NOW REQUIRES A GLENOID COMPONENT. SURGEON ELECTED TO DOWNSIZE THE HEAD TO A 52X15 STD, CHANGE TO A 135 TAPER, AND IMPLANT AN XL INHANCE GLENOID. DOI: UNKNOWN. DOR: MARCH 9, 2026. AFFECTED SIDE: LEFT SHOULDER. IT WAS REPORTED THAT THE HEAD AND LINER WAS REVISED FOR UNKNOWN REASON.
Patient problems: Arthritis
MAUDE report 24701580 ↗InjuryFeb 28, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT PATIENT HAD FRACTURED AT RIGHT SHOULDER BACK IN 2013 AND HAD A HEMI ARTHROPLASTY REPLACEMENT USING A GLOBAL UNITE FX IMPLANT. SURGEON'S OFFICE CALLED AND SCHEDULED A SURGERY REQUESTING DEPUY EQUIPMENT TO CONVERT THE GLOBAL UNITE FX HEMI CONSTRUCT TO A REVERSE SHOULDER CONSTRUCT. SURGEON EXPLANTED THE HUMERAL HEAD IMPLANT, THE SUTURE COLLAR, AND THE PROXIMAL BODY AND LEFT THE WELL FIXED STEM IN PLACE. THE CONVERSION INSTRUMENTATION WAS USED AND A NEW REVERSE SHOULDER CONSTRUCT WAS IMPLANTED. DOI: (B)(6) 2013; DOR: (B)(6) 2019; RIGHT SHOULDER.
Patient problems: Discomfort; No Code Available
MAUDE report 8377806 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K101996, K170748. One submission often covers many models, so check the product and lot details in each record.
- Z-0490-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE STD STEM SZ 16 Product Code: 110016100
- Z-0484-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE STD STEM SZ 8 Part Number: 110008100
- Z-0483-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE STD STEM SZ 6 Part Number: 11000610
- Z-0488-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE STD STEM SZ 12 Product Code: 110012100
- Z-0489-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE STD STEM SZ 14 Product Code: 110014100
- Z-0486-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE STD STEM SZ 10 Part Number: 110010100
- Z-0485-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE REV STEM SZ 8 Part Number: 110008600
- Z-0487-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE REV STEM SZ 10 Product Code: 110010600
Other PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED devices
- DJO SURGICAL 508-32-204Encore Medical, L.P. · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED1 recall544 reports
- Comprehensive Reverse Shoulder 010000589Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED1 recall142 reports
- DELTA XTEND 130738203Depuy (Ireland) · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED175 reports
- DJO SURGICAL 509-00-432Encore Medical, L.P. · Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented1 recall117 reports
- Alliance® SBGL3007Zimmer, Inc. · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED162 reports
- DELTA XTEND 130760138Depuy (Ireland) · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED146 reports
- DELTA XTEND 130790030Depuy (Ireland) · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED132 reports
- DJO SURGICAL 509-00-436Encore Medical, L.P. · Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented124 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page