Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10603295005483), received between Jan 15, 2020 and Nov 10, 2025 — classified as 4 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Device Dislodged or Dislocated1
  • Loss of Osseointegration1
  • Use of Device Problem1

Patient problems

  • Pain2
  • Inadequate Osseointegration1
  • No Code Available1
  • Unspecified Tissue Injury1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 10, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT PATIENT UNDERWENT REVISION FROM A GLOBAL AP TO A DELTA EXTEND DUE TO CUFF TEAR AND SUPERIOR MIGRATION OF THE HUMERUS.

    Patient problems: Unspecified Tissue Injury

    MAUDE report 23512096 ↗
  • InjuryJun 4, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT BEGAN EXPERIENCING PAIN. IMPLANTS WERE IN GOOD CONDITION. THE CEMENT MANUFACTURER WAS MARKED AS DEPUY. AFFECTED SIDE: UNKNOWN SHOULDER SIDE.

    Patient problems: Pain

    MAUDE report 22140881 ↗
  • InjuryMar 5, 2024Use of Device Problem; Use of Device Problem

    ADDITIONAL INFORMATION WAS RECEIVED: A. WAS THERE ANY PATIENT CONSEQUENCE RELATED TO THE EVENT. - WE REVISED THE SHOULDER AS DESCRIBED IN THE PC. B. WAS THERE ANY SURGICAL DELAY RELATED TO THE EVENT? - SURGICAL DELAY QUESTION IS NOT REALLY APPLICABLE AS THE ENTIRE SURGERY WAS A REVISION.

    Patient problems: Pain

    MAUDE report 18836369 ↗
  • InjuryJan 15, 2020Loss of Osseointegration; Device Dislodged or Dislocated; Loss of Osseointegration; Device Dislodged or Dislocated

    THE PATIENT WAS REVISED TO ADDRESS LOOSENING OF NON-CEMENTED STEM. THE TAPER DID NOT ENGAGE BETWEEN THE HEAD AND THE STEM. DOI: UNKNOWN. DOR: (B)(6) 2020; UNKNOWN SIDE.

    Patient problems: Inadequate Osseointegration; No Code Available

    MAUDE report 9592676 ↗