Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10603295009450), received between Dec 19, 2018 and Dec 19, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Material Disintegration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Material Disintegration1
- Noise, Audible1
- Separation Problem1
Patient problems
- No Code Available1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryDec 19, 2018Material Disintegration; Noise, Audible; Separation Problem; Material Disintegration; Noise, Audible; Separation Problem
IT WAS REPORTED THAT THE PATIENT PRESENTED TO THE SURGEON WITH PAIN AND CLICKING IN HER HIP. ON X-RAY, IT APPEARED THAT THE POLY HAD WORN THRU. KNOWING IT HAD ONLY BEEN IN 1.5 YEARS, THIS WAS LIKELY NOT THE CASE. THE PATIENT HAD NO RECOLLECTION OF A TRAUMATIC EVENT, NEVERTHELESS THE SURGEON SUSPECTED THAT THE LINER SPUN OUT AT ONE POINT. UPON EXAMINATION IN THE OR, THE METAL HEAD HAD INDEED BEEN ARTICULATING ON THE METAL SHELL AND WORN DOWN THE METAL ON THE RIM OF THE SHELL. THE CUP WAS REMOVED BECAUSE THE LOCKING TAPER IN THE SHELL HAD BEEN COMPROMISED. THE 54 DEEP PROFILE CUP WAS REPLACED WITH A 56 MULTI-GRIP WITH A 40 LINER AND METAL +5 HEAD.
Patient problems: No Code Available; Pain
MAUDE report 8181944 ↗
Other PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED devices
- PINNACLE 1217-25-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED735 reports
- NA 1365-52-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED683 reports
- APEX 1246-03-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED3 deaths613 reports
- PINNACLE 1217-20-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED2 deaths590 reports
- PINNACLE 1217-30-500Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED1 death484 reports
- NA 1365-53-000Depuy (Ireland) · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED404 reports
- PINNACLE ALTRX 1221-36-054Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED388 reports
- PINNACLE ALTRX 1221-32-050Depuy Orthopaedics, Inc. · PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED386 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page