Skip to content

LCS COMPLETE 1294-09-860Recalls & reported problems

Depuy Orthopaedics, Inc. · LCS COMPLETE 3 Peg Patella Metal Backed Poly Replacement LRG · Class 3 · Implant

All models of LCS COMPLETE (117)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
9
Deaths reported
0
Injuries reported
9
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 10603295022800), received between May 9, 2019 and Jun 15, 2026 — classified as 9 injuries.

The most frequently reported specific device problem is “Naturally Worn” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem5
  • Naturally Worn3
  • Fracture1

Patient problems

  • Pain4
  • No Code Available3
  • Insufficient Information2
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Wound Dehiscence1

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 15, 2026Naturally Worn

    IT WAS REPORTED THAT PATELLA POLY WEAR. TIBIAL INSERT WEAR. AFFECTED SIDE: RIGHT KNEE.

    Patient problems: Insufficient Information

    MAUDE report 25505574 ↗
  • InjuryApr 21, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT HAD A WOUND DEHISCENCE FOLLOWING A PATELLAR SWAP AND I&D A MONTH PRIOR. SURGEON DECIDED TO OPEN THE JOINT AND WASH OUT WHILE REVISING THE WOUND. POLY AND PATELLA POLY WERE REPLACED DURING THE WASH OUT. AFFECTED SIDE: LEFT KNEE.

    Patient problems: Wound Dehiscence

    MAUDE report 21878013 ↗
  • InjuryMar 21, 2025Naturally Worn; Naturally Worn

    IT WAS REPORTED THAT PATELLA BUTTON HAD WEAR AND WAS REPLACED ALONG WITH AN I&D OF THE LEFT KNEE. THERE WAS NO SURGICAL DELAY; NO PATIENT CONSEQUENCE. DOI: UNKNOWN. DOR: (B)(6) 2025. AFFECTED SIDE: LEFT KNEE.

    Patient problems: Insufficient Information

    MAUDE report 21666581 ↗
  • InjuryOct 14, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT WAS REVISED DUE TO PAINFUL RIGHT KNEE. THERE WAS NO SURGICAL DELAY. DOI: (B)(6) 2016. DOR: (B)(6) 2022. AFFECTED SIDE: RIGHT KNEE.

    Patient problems: Pain

    MAUDE report 15604967 ↗
  • InjuryNov 8, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT'S KNEE WAS REVISED DUE TO PAIN. DOI: UNK. DOR: (B)(6) 2021. RIGHT KNEE.

    Patient problems: Pain

    MAUDE report 12770942 ↗
  • InjuryJan 22, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS REVISED TO ADDRESS MCL DEFICIENT. ORIGINAL IMPLANT DATE UNKNOWN. NO SURGICAL DELAY. DOI: UNKNOWN; DOR: (B)(6) 2021; LEFT KNEE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 11212903 ↗
  • InjuryJul 14, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS REVISED DUE TO PAIN. DOI: (B)(6) 2000, DOR: (B)(6) 2020, RIGHT KNEE.

    Patient problems: No Code Available; Pain

    MAUDE report 10270956 ↗
  • InjuryMay 20, 2019Fracture; Fracture

    IT WAS REPORTED THAT PATIENT HAD A LCS COMPLETE PRESSFIT KNEE DONE APPROXIMATELY 10 YEARS AGO. PATIENT FELL IN DECEMBER AND FRACTURED THE POLY OF THE METAL BACKED PATELLA. THE PATELLA WAS REVISED AND A NEW POLY PATELLA WAS ATTACHED TO THE RETAINED METAL BACKED PATELLA BASE. THE PRESSFIT FEMUR AND TIBIA WERE WELL FIXED AND RETAINED AS WELL AS THE POLY TIBIAL INSERT. DOI: 10 YEARS AGO; DOR: (B)(6) 2019, LEFT KNEE.

    Patient problems: No Code Available

    MAUDE report 8623414 ↗
  • InjuryMay 9, 2019Naturally Worn; Naturally Worn

    IT WAS REPORTED THAT THE POLY WAS REPLACED. THE WORN POLY WAS LEADING TO PAIN. DOI: UNKNOWN. DOR: (B)(6) 2019. LEFT KNEE.

    Patient problems: No Code Available; Pain

    MAUDE report 8596645 ↗

Other Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices

All Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices →

Sources and updates