ATTUNE 1516-30-507Recalls & reported problems

Depuy (Ireland) · ATTUNE KNEE SYSTEM TIBIAL INSERT ROTATING PLATFORM CRUCIATE RETAINING SIZE 5 7mm AOX · Class 3 · Implant

All models of ATTUNE (1475)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
23
Deaths reported
0
Injuries reported
17
Recalls naming it
0

Summary

The FDA's MAUDE database contains 23 adverse event reports that list this exact device (DI 10603295047766), received between Oct 26, 2017 and Sep 26, 2024 — classified as 17 injuries, 6 malfunctions.

The most frequently reported specific device problem is “Device Contaminated During Manufacture or Shipping” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem14
  • Device Contaminated During Manufacture or Shipping6
  • Tear, Rip or Hole in Device Packaging5
  • Unintended Movement2
  • Device Dislodged or Dislocated1
  • Insufficient Device Problem Information1
  • No Apparent Adverse Event1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7
  • No Code Available6
  • Pain6
  • Unspecified Infection4
  • Muscular Rigidity3
  • Insufficient Information2
  • Joint Dislocation2
  • Adhesion(s)1

Recent adverse event reports

The 23 most recent of 23 reports, in the reporter's own words as published by the FDA.

  • InjurySep 26, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ADDITIONAL INFORMATION WAS RECEIVED: B. WAS INSTABILITY RELATED TO POLYETHYLENE WEAR? NO. C. WAS THERE ANY REPORTED MALPOSITION OF COMPONENTS THAT LED TO THE INSTABILITY? NO. D. WERE ANY COMPONENTS UNDERSIZED ON THE PRIMARY SURGERY THAT LED TO THE INSTABILITY? NO. E. WAS THE FEMUR OR TIBIA EXCESSIVELY RESECTED/JOINT LINE RAISED DURING THE PRIMARY SURGERY THAT LED TO THE INSTABILITY? NO.

    Patient problems: Joint Laxity

    MAUDE report 20311240 ↗
  • InjuryMar 22, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT WAS REVISED DUE TO INFECTION. SURGEON EXPLANTED THE IMPLANTS. DOI: (B)(6) 2022. DOR: (B)(6) 2024. AFFECTED SIDE: LEFT KNEE.

    Patient problems: Unspecified Infection

    MAUDE report 18960336 ↗
  • InjuryFeb 7, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT WAS REVISED DUE TO WASHOUT FOR INFECTION. IT WAS UNKNOWN IF THERE WAS ANY SURGICAL DELAY. DOR: (B)(6) 2024 AFFECTED SIDE: LEFT

    Patient problems: Unspecified Infection

    MAUDE report 18659566 ↗
  • InjuryDec 22, 2023Device Dislodged or Dislocated; Unintended Movement; Device Dislodged or Dislocated; Unintended Movement

    ADDITIONAL INFORMATION WAS RECEIVED AND STATED THAT THE INSERT HAD SPUN OUT.

    Patient problems: Insufficient Information; Joint Dislocation

    MAUDE report 18382779 ↗
  • InjuryOct 27, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ADDITIONAL INFORMATION RECEIVED. WHAT IS THE EVENT DATE? I¿M NOT SURE OF THE EXACT DATE SORRY. PATIENT NOTES ONLY HAD THE YEAR. CAN YOU PLEASE CONFIRM THE MANUFACTURER OF THE CEMENT PRODUCT? IF DEPUY, PLEASE PROVIDE THE PRODUCT CODE AND LOT NO. OF THE REPORTED PRODUCT. THIS SURGEON CURRENTLY USES DEPUY CEMENT, BUT I CAN¿T CONFIRM IF IT WAS USED AT THIS TIME. CAN YOU CONFIRM THE PRIMARY SURGERY DATE OR THE ORIGINAL IMPLANTATION DATE? SORRY PATIENT NOTES ONLY SHOWED THE YEAR, NOT THE EXACT DATE. IMPLANT SCREENSHOTS WHICH I PROVIDED ON A PREVIOUS EMAIL WILL BE WITHIN A DAY OR SO OF (B)(6) 2018 WHAT WAS THE REASON FOR DEBRIDEMENT AND MUA IN 2019? WAS THERE ANY ADVERSE CONSEQUENCES/SYMPTOMS THAT AFFECTED THE PATIENT BECAUSE OF THE REPORTED EVENT? REASON FOR MUA AND DEBRIDEMENT WAS DUE TO STIFFNESS AND PAIN. NO ADVERSE CONSEQUENCES NOTED.

    Patient problems: Insufficient Information; Muscular Rigidity; Pain

    MAUDE report 18021580 ↗
  • InjuryOct 25, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THIS CASE IS LOGGED TO CAPTURE THE PREVIOUS REVISION (2020) MENTIONED IN (B)(4). REVISION OF AN ATTUNE. RIGHT SIDE. PRIMARY WAS DONE IN [YEAR] IN [HOSPITAL] BY [SURGEON]. THEY HAD A DEBRIDEMENT AND MUA IN [YEAR]. REVISION OF THE FEMORAL COMPONENT AND INSERT IN [YEAR]. THIS WAS DONE IN [YEAR] BY [SURGEON]. I¿M NOT SURE WHAT THE PC NUMBER IS FOR THIS. THEY HAVE HAD ONGOING ISSUES SINCE FIRST SURGERY IN [YEAR]. THIS REVISION WAS DUE TO STIFFNESS AND PAIN. UNSURE OF THE LOT NUMBERS FOR THE FEMORAL COMPONENT AND TIBIAL COMPONENT REMOVED. WAS SURGERY DELAYED DUE TO THE REPORTED EVENT? UNKNOWN, WAS PROCEDURE SUCCESSFULLY COMPLETED? UNKNOWN, WERE FRAGMENTS GENERATED? UNKNOWN, IF YES, WERE THEY REMOVED EASILY WITHOUT ADDITIONAL INTERVENTION? UNKNOWN, PATIENT STATUS/ OUTCOME / CONSEQUENCES , WAS OTHER MEDICAL INTERVENTION (E.G. X-RAYS, ADDITIONAL PROCEDURES, PRESCRIPTIONS, OTC, REVISION) REQUIRED: UNKNOWN, IS THE PATIENT PART OF A CLINICAL STUDY: UNKNOWN, (B)(4). DEVICE PROPERTY OF: NONE, DEVICE IN POSSESSION OF: NONE, (B)(4). DEVICE PROPERTY OF: NONE, DEVICE IN POSSESSION OF: NONE BY CHECKING THIS BOX I CERTIFY THAT ALL INFORMATION THAT ARE KNOWN/AVAILABLE HAS BEEN DISCLOSED. IF ANY NEW INF

    Patient problems: Muscular Rigidity; Pain

    MAUDE report 18003781 ↗
  • MalfunctionDec 21, 2022Tear, Rip or Hole in Device Packaging; Device Contaminated During Manufacture or Shipping; Tear, Rip or Hole in Device Packaging; Device Contaminated During Manufacture or Shipping

    IT WAS REPORTED THAT THE SURGEON WAS NOT HAPPY WITH THE DISCOLORATION ON THE BOX AND THE INNER PACKAGING OF THE PROTHESIS, SO HE CHOSE TO NOT USE THE AFFECTED PRODUCT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16022345 ↗
  • MalfunctionDec 21, 2022Tear, Rip or Hole in Device Packaging; Device Contaminated During Manufacture or Shipping; Tear, Rip or Hole in Device Packaging; Device Contaminated During Manufacture or Shipping

    IT WAS REPORTED THAT THE SURGEON WAS NOT HAPPY WITH THE DISCOLORATION ON THE BOX AND THE INNER PACKAGING OF THE PROTHESIS, SO HE CHOSE TO NOT USE THE AFFECTED PRODUCT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16022344 ↗
  • MalfunctionDec 21, 2022Tear, Rip or Hole in Device Packaging; Device Contaminated During Manufacture or Shipping; Tear, Rip or Hole in Device Packaging; Device Contaminated During Manufacture or Shipping

    IT WAS REPORTED THAT THE SURGEON WAS NOT HAPPY WITH THE DISCOLORATION ON THE BOX AND THE INNER PACKAGING OF THE PROTHESIS, SO HE CHOSE TO NOT USE THE AFFECTED PRODUCT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16022343 ↗
  • MalfunctionDec 21, 2022Tear, Rip or Hole in Device Packaging; Device Contaminated During Manufacture or Shipping; Tear, Rip or Hole in Device Packaging; Device Contaminated During Manufacture or Shipping

    IT WAS REPORTED THAT THE SURGEON WAS NOT HAPPY WITH THE DISCOLORATION ON THE BOX AND THE INNER PACKAGING OF THE PROTHESIS, SO HE CHOSE TO NOT USE THE AFFECTED PRODUCT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16022339 ↗
  • MalfunctionDec 21, 2022Tear, Rip or Hole in Device Packaging; Device Contaminated During Manufacture or Shipping; Tear, Rip or Hole in Device Packaging; Device Contaminated During Manufacture or Shipping

    IT WAS REPORTED THAT THE SURGEON WAS NOT HAPPY WITH THE DISCOLORATION ON THE BOX AND THE INNER PACKAGING OF THE PROTHESIS, SO HE CHOSE TO NOT USE THE AFFECTED PRODUCT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16022338 ↗
  • InjuryOct 31, 2022Adverse Event Without Identified Device or Use Problem; No Apparent Adverse Event; Adverse Event Without Identified Device or Use Problem; No Apparent Adverse Event

    CLINICAL ADVERSE EVENT RECEIVED FOR FALL. EVENT IS NOT SERIOUS AND IS CONSIDERED MODERATE. EVENT IS POSSIBLY RELATED TO PROCEDURE. EVENT IS NOT RELATED TO DEVICE. DATE OF IMPLANT: (B)(6) 2015. DATE OF EVENT: (B)(6) 2021. LEFT KNEE. TREATMENT: POST PROCEDURE CAST TO MAINTAIN POSITION OF DISLOCATED (L) ELBOW & EPICONDYLE AVULSION FRACTURE, PHYSICAL THERAPY, OBSERVATION, AND MANIPULATION UNDER ANESTHESIA.

    Patient problems: Fall; No Clinical Signs, Symptoms or Conditions

    MAUDE report 15698721 ↗
  • InjuryApr 5, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    CLINICAL ADVERSE EVENT RECEIVED FOR LARGE MEDIAL HEMATOMA ON LEFT KNEE AT INCISION SITE. EVENT IS SERIOUS AND IS CONSIDERED MODERATE. EVENT IS NOT RELATED TO DEVICE AND IS POSSIBLY RELATED TO PROCEDURE. DATE OF IMPLANTATION: (B)(6) 2017; DATE OF EVENT (ONSET): (B)(6) 2017; (LEFT KNEE). TREATMENT: MEDICAL INTERVENTION/MODIFICATION: SURGICAL ASPIRATION AND EVACUATION OF HEMATOMA.

    Patient problems: Hematoma

    MAUDE report 14014761 ↗
  • InjuryAug 19, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE KNEE WAS TIGHT DUE TO SCAR TISSUE. DOI: (B)(6) 2020. DOR: (B)(6) 2021, RIGHT KNEE.

    Patient problems: Adhesion(s); Muscular Rigidity

    MAUDE report 12341788 ↗
  • MalfunctionApr 7, 2021Device Contaminated During Manufacture or Shipping; Device Contaminated During Manufacture or Shipping

    ADDITIONAL INFORMATION RECEIVED STATES THAT THE INSERT WAS NEVER IMPLANTED IN A PATIENT. THE IMPLANT WAS NEVER OPENED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11631897 ↗
  • InjuryDec 29, 2020Unintended Movement; Unintended Movement

    PATIENT SPUN OUT BEARING AND KNEE DISLOCATED.

    Patient problems: Joint Dislocation; Pain

    MAUDE report 11089269 ↗
  • InjuryOct 14, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SUBJECT ID: (B)(6). STUDY: (B)(6). CLINICAL ADVERSE EVENT RECEIVED FOR PAIN, SWELLING, AND INSTABILITY, WITH LOOSENING OF IMPLANT, RIGHT KNEE EVENT IS SERIOUS AND IS CONSIDERED SEVERE. EVENT IS DEFINITELY RELATED TO DEVICE AND IS POSSIBLY RELATED TO PROCEDURE. DATE OF IMPLANTATION: (B)(6) 2018, DATE OF EVENT (ONSET): (B)(6) 2019, (RIGHT KNEE). TREATMENT: MEDICAL INTERVENTION - ANALGESICS; DIAGNOSTIC INTERVENTIONS - CT, SCINTIGRAPHY (INVASIVE-RADIOISOTOPES INJECTED), ULTRASOUND; PHYSICAL THERAPY; REVISION SURGERY ON (B)(6) 2020 WITH EXPLANTATION OF STUDY KNEE. PATELLA WAS NOT RESURFACED DURING PRIMARY.

    Patient problems: Edema; No Code Available; Pain

    MAUDE report 10679326 ↗
  • InjuryJul 10, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT REMOVAL OF ARTICULATING ATTUNE ANTIBIOTIC SPACER WAS PERFORMED AND PLACEMENT OF AN ATTUNE REVISION CONSTRUCT DUE TO INFECTION ABATEMENT. DOI: UNKNOWN, DOR: (B)(6) 2020, RIGHT KNEE.

    Patient problems: No Code Available; Unspecified Infection

    MAUDE report 10258325 ↗
  • InjuryMar 17, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    INFECTED TOTAL KNEE, INSERT REMOVED AND WASHED OUT AND NEW INSERT PLACED.

    Patient problems: No Code Available; Unspecified Infection

    MAUDE report 9842918 ↗
  • InjuryFeb 18, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    CLINICAL NOTIFICATION RECEIVED FOR REVISION OF LEFT TOTAL KNEE REPLACEMENT. DATE OF IMPLANTATION: (B)(6) 2018; DATE OF REVISION: (B)(6) 2019; (LEFT KNEE).

    Patient problems: No Code Available

    MAUDE report 9722618 ↗
  • InjuryJul 30, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    CLINICAL ADVERSE EVENT RECEIVED FOR POSTERIOR COLLAPSE OF THE TIBIAL METAPHYSEAL BONE WITH INCREASED SLOPE OF THE TIBIAL COMPONENT AND POSTERIOR SUBLUXATION OF THE FEMORAL COMPONENT. EVENT IS SERIOUS AND IS CONSIDERED MODERATE. EVENT IS DEFINITELY RELATED TO DEVICE AND POSSIBLY RELATED TO PROCEDURE. DATE OF IMPLANTATION: (B)(6) 2017; DATE OF EVENT (ONSET): (B)(6) 2018; (LEFT KNEE).

    Patient problems: Failure of Implant

    MAUDE report 8842894 ↗
  • InjuryDec 11, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS REVISED TO ADDRESS PAINFUL KNEE DUE TO INSTABILITY.

    Patient problems: No Code Available; Pain

    MAUDE report 8151373 ↗
  • InjuryOct 26, 2017Insufficient Device Problem Information; Insufficient Device Problem Information

    THE PATIENT WAS REVISED TO ADDRESS PAIN AND INSTABILITY.

    Patient problems: No Code Available; Pain

    MAUDE report 6980254 ↗

Other Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices

All Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices →