ATTUNE 1516-30-806Recalls & reported problems

Depuy (Ireland) · ATTUNE KNEE SYSTEM TIBIAL INSERT ROTATING PLATFORM CRUCIATE RETAINING SIZE 8 6mm AOX · Class 3 · Implant

All models of ATTUNE (1475)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
14
Deaths reported
0
Injuries reported
14
Recalls naming it
0

Summary

The FDA's MAUDE database contains 14 adverse event reports that list this exact device (DI 10603295048114), received between Nov 26, 2018 and Oct 9, 2024 — classified as 14 injuries.

The most frequently reported specific device problem is “Naturally Worn” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem11
  • Appropriate Device Problem Term/Code Not Available1
  • Naturally Worn1
  • No Apparent Adverse Event1

Patient problems

  • No Code Available7
  • Unspecified Infection7
  • Pain6
  • Adhesion(s)3
  • Hypersensitivity/Allergic reaction1
  • Joint Laxity1
  • Limited Mobility Of The Implanted Joint1
  • Loss of Range of Motion1

Recent adverse event reports

The 14 most recent of 14 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 9, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT DID WELL FOR A COUPLE YEARS POST TOTAL KNEE REPLACEMENT AND THEN THEY STARTED LOSING RANGE OF MOTION. 6MM POLY WAS REMOVED AND SCAR TISSUE WAS REMOVED. 5MM POLY WAS PUT IN AND THE KNEE WAS STABLE, AND RANGE OF MOTION WAS RESTORED. THERE WAS NO SURGICAL DELAY. DOI: (B)(6) 2022. DOR: (B)(6) 2024. AFFECTED SIDE: RIGHT KNEE.

    Patient problems: Loss of Range of Motion; Scar Tissue

    MAUDE report 20411543 ↗
  • InjuryApr 30, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT SYNOVECTOMY WAS PERFORMED, CHANGING THE POLY WITHOUT ANY DELAYS. DOI: (B)(6) 2021. DOR: (B)(6) 2024. AFFECTED SIDE: RIGHT KNEE.

    Patient problems: Synovitis

    MAUDE report 19215146 ↗
  • InjuryJan 17, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT PATIENT KNEE WAS INFECTED. PLOY WAS SWAPPED. SAME SIZE REPLACED. NO DEFECT WITH THE DEPUY PRODUCT. THERE WAS NO SURGICAL DELAY. DOI: UNKNOWN. DOR: JAN 9, 2024. AFFECTED SIDE: UNKNOWN KNEE SIDE.

    Patient problems: Unspecified Infection

    MAUDE report 18526312 ↗
  • InjuryJul 14, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION OF AN ATTUNE CR RP CONSTRUCT DONE DUE TO LOOSENING AND INFECTION. THE SURGEON SAID THAT THE PATIENT EXPERIENCED PAIN FROM EARLY ON AFTER THE SURGERY SO SAID THEY PROBABLY GOT THE INFECTION FROM THE START. IMPLANTS WERE LOOSE AT THE CEMENT/BONE INTERFACE. SIMPLEX CEMENT WAS USED. DOI: (B)(6) 2021. DOR: (B)(6) 2023. RIGHT KNEE.

    Patient problems: Pain; Unspecified Infection

    MAUDE report 17324473 ↗
  • InjuryJun 28, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT WAS REVISED DUE TO INFECTED KNEE. SPACER PLACED WITH ANTIBIOTICS. CEMENT MANUFACTURER WAS COMPETITOR. THERE WAS NO SURGICAL DELAY. DOI: (B)(6) 2022. DOR: (B)(6) 2023. AFFECTED SIDE: LEFT KNEE.

    Patient problems: Unspecified Infection

    MAUDE report 17217920 ↗
  • InjuryMay 10, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    CLINICAL NOTIFICATION RECEIVED FOR REVISION OF RIGHT TOTAL KNEE TO ADDRESS PAIN/STIFFNESS AND INSTABILITY. DATE OF IMPLANTATION: (B)(6) 2020. DATE OF REVISION: (B)(6) 2022. (RIGHT KNEE). TREATMENT: REVISION OF TIBIAL INSERT.

    Patient problems: Joint Laxity; Muscular Rigidity; Pain

    MAUDE report 14345432 ↗
  • InjuryOct 19, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS REVISED DUE TO INFECTION. REPLACED THE SAME SIZE POLY FOR A NEW ONE. DOI: (B)(6) 2020; DOR: (B)(6) 2020; LEFT KNEE.

    Patient problems: No Code Available; Unspecified Infection

    MAUDE report 10698157 ↗
  • InjuryNov 20, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT UNDERWENT A LEFT KNEE REVISION DUE TO INSTABILITY, ADHESIONS, AND TIBIAL TRAY LOOSENING AT THE CEMENT TO IMPLANT INTERFACE. THE SURGEON NOTED GROSS LAXITY AND FLEXION PRIMARILY WITH A DEFICIENCY OF THE POSTERIOR CRUCIATE LIGAMENT. THE PATELLA COMPONENT WAS NOT REVISED. DEPUY CEMENT WAS USED DURING THE PRIMARY OPERATION. DOI: (B)(6) 2014; DOR: (B)(6) 2019; LEFT KNEE.

    Patient problems: Adhesion(s); No Code Available

    MAUDE report 9348211 ↗
  • InjuryNov 18, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT UNDERWENT A LEFT KNEE REVISION DUE TO PAIN, DECREASED RANGE OF MOTION, ADHESIONS, AND TIBIAL TRAY LOOSENING AT THE CEMENT TO IMPLANT INTERFACE. ALL COMPONENTS WERE REVISED. TWO DEPUY CEMENT PRODUCTS WERE USED DURING THE PRIMARY OPERATION. DOI: (B)(6) 2014 DOR: (B)(6) 2016 LEFT KNEE.

    Patient problems: Adhesion(s); Limited Mobility Of The Implanted Joint; No Code Available; Pain

    MAUDE report 9337381 ↗
  • InjuryNov 4, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    MEDICAL RECORDS RECEIVED AD 17 JUNE 2019. THE PATIENT UNDERWENT A LEFT KNEE REVISION DUE TO PAIN, METAL ALLERGY TO NICKEL, ADHESIONS, AND TIBIAL TRAY LOOSENING AT THE CEMENT TO IMPLANT INTERFACE. THE PATELLA COMPONENT WAS NOT REVISED. TWO DEPUY CEMENT PRODUCTS WERE USED DURING THE PRIMARY OPERATION. DOI: (B)(6) 2017. DOR: (B)(6) 2018 LEFT KNEE.

    Patient problems: Adhesion(s); Hypersensitivity/Allergic reaction; No Code Available; Pain

    MAUDE report 9273823 ↗
  • InjuryApr 30, 2019Naturally Worn; Naturally Worn

    RIGHT KNEE. REASON FOR REVISION: PAIN. UPON OPENING THE KNEE THERE WERE SIGNS OF INFECTION. SAMPLES WERE SENT TO THE LAB FOR EXAMINATION. ALL IMPLANTS WERE FOUND TO BE WELL FIXED BUT WERE REMOVED. THE KNEE WAS THOROUGHLY WASHED OUT AND AN INTERIM PROSTHESIS CEMENTED IN WITH GENTAMICIN CEMENT MIXED WITH VANCOMYCIN. THE TIBIAL INSERT WAS RETAINED AND DECONTAMINATED. IT SHOWS EVIDENCE OF PUTTING AND THE SURGEON WOULD LIKE IT EXAMINED AND REPORTED ON. IT IS AVAILABLE FOR RETURN. ALL OTHER IMPLANTS HAVE BEEN DISCARDED.

    Patient problems: No Code Available; Pain; Unspecified Infection

    MAUDE report 8566542 ↗
  • InjuryApr 17, 2019No Apparent Adverse Event; No Apparent Adverse Event

    ATTUNE CR RP REVISION FOR PAIN/STIFFNESS.

    Patient problems: No Code Available; Pain

    MAUDE report 8524551 ↗
  • InjuryDec 13, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS REVISED TO ADDRESS INFECTION AND LOOSENING OF THE TIBIAL COMPONENT AT THE BONE TO IMPLANT INTERFACE. ORIGINAL ATTUNE CEMENTLESS CR RP IMPLANTS WERE IMPLANTED ON (B)(6) 2018 BY DIFFERENT SURGEON.

    Patient problems: No Code Available; Unspecified Infection

    MAUDE report 8160079 ↗
  • InjuryNov 26, 2018Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    PATIENT WAS REVISED TO ADDRESS INFECTION.

    Patient problems: Unspecified Infection

    MAUDE report 8103724 ↗

Other Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices

All Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page