ATTUNE 1516-30-906Recalls & reported problems
Depuy (Ireland) · ATTUNE KNEE SYSTEM TIBIAL INSERT ROTATING PLATFORM CRUCIATE RETAINING SIZE 9 6mm AOX · Class 3 · Implant
All models of ATTUNE (1475)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10603295048237), received between Oct 5, 2018 and Jul 14, 2025 — classified as 4 injuries.
The most frequently reported specific device problem is “Loose or Intermittent Connection” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Loose or Intermittent Connection1
Patient problems
- No Code Available2
- Unspecified Infection2
- Not Applicable1
- Pain1
- Tissue Damage1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryJul 14, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PATIENT WAS REVISED DUE TO AN INFECTED TKA. DOI: UNKNOWN, DOR: (B)(6) 2025, AFFECTED SIDE: RIGHT KNEE.
Patient problems: Unspecified Infection
MAUDE report 22496947 ↗InjuryNov 17, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PATIENT UNDERWENT A PRIMARY ATTUNE TKR ON THE (B)(6) 2020. PATIENT EXPERIENCED INSTABILITY APPROXIMATELY TWO WEEKS POST-OP; SURGEON SUSPECTS HE "WENT TOO HARD TOO SOON" AND DAMAGED SOME SOFT TISSUES WHICH CAUSED SOME FLEXION INSTABILITY. INSERT WAS REVISED TO A THICKER ONE AND THE KNEE FELT AND LOOKED STABLE AGAIN ON THE TABLE. IF OTHER, DESCRIBE --> N/A, IF OTHER, DESCRIBE --> TOTAL KNEE REPLACEMENT, DID THE PATIENT EXPERIENCE A POST-OP DEVICE MALFUNCTION? --> YES, IF YES, PLEASE DESCRIBE. --> POST-OP INSTABILITY., DID THE PATIENT EXPERIENCE AN ADVERSE EVENT SUCH AS INFECTION, NON-UNION, ALLERGIC REACTION, OSTEOPOROSIS, OVERLOADING, PAIN, DEGENERATIVE DISEASES, BLEEDING OR OOZING? --> YES, DID THE PATIENT REQUIRE REVISION SURGERY OR HARDWARE REMOVAL? --> YES, FACILITY NAME OF ORIGINAL IMPLANT --> SJOG MIDLAND, WAS DEVICE EXPLANTED? --> TRUE, HARDWARE/EXPLANT REMOVAL DUE TO: --> INSTABILITY, DID PATIENT REQUIRE REVISION SURGERY? --> TRUE, IF YES, DATE OF REVISION SURGERY. --> (B)(6) 2020, REASON FOR REVISION SURGERY. --> INSTABILITY, IF NO, WAS THERE ANY ADDITIONAL MEDICAL INTERVENTION REQUIRED SUCH AS X-RAYS, ADDITIONAL PROCEDURES, PRESCRIPTIONS? --> N/A, PATIENT STATUS/ OUTCOME /
Patient problems: No Code Available; Tissue Damage
MAUDE report 10857391 ↗InjuryFeb 18, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS REVISED DUE TO INFECTION. POLY EXCHANGE WAS PERFORMED. DOI: UNKNOWN; DOR: (B)(6) 2020; RIGHT KNEE.
Patient problems: No Code Available; Unspecified Infection
MAUDE report 9721769 ↗InjuryOct 5, 2018Loose or Intermittent Connection; Loose or Intermittent Connection
PATIENT WAS REVISED TO ADDRESS PAIN AND LOOSENING OF THE TIBIA COMPONENT AT THE CEMENT TO IMPLANT INTERFACE.
Patient problems: Not Applicable; Pain
MAUDE report 7940334 ↗
Other Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices
- ATTUNE 1506-10-005Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing442 reports
- ATTUNE 1506-10-004Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing442 reports
- ATTUNE 1518-20-038Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing3 deaths393 reports
- LCS SIGMA 1294-33-130Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing1 recall310 reports
- ATTUNE 1518-20-035Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing342 reports
- P.F.C. SIGMA 96-0102Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing1 death319 reports
- ATTUNE 1518-20-041Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing308 reports
- ATTUNE 1506-10-007Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing284 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page