SIGMA 1960-74-500Recalls & reported problems
Depuy (Ireland) · SIGMA FEMORAL POSTERIOR STABILIZED LUGGED CEMENTED SIZE 4 RIGHT · Class 3 · Implant
All models of SIGMA (380)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 7
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 10603295075486), received between Oct 18, 2017 and Mar 21, 2024 — classified as 7 injuries.
The most frequently reported specific device problem is “Loss of or Failure to Bond” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem4
- Loss of or Failure to Bond2
- Insufficient Device Problem Information1
Patient problems
- Joint Laxity2
- Pain2
- Unspecified Infection2
- Fall1
- No Information1
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
InjuryMar 21, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PATIENT WAS REVISED DUE TO LOOSENING OF THE PATELLA AT THE BONE TO CEMENT INTERFACE. CEMENT MANUFACTURER WAS UNKNOWN. PATIENT HAD A FALL SEVERAL YEARS AGO, POSSIBLY DISLODGED HIS PATELLA IMPLANT, DID NOT WANT SURGERY. CURRENTLY PATIENT HAS A KNOWN INFECTION. ALL PARTS WERE REMOVED AND A SPACER PUT IN W ANTIBIOTIC CEMENT. NO DELAY. NO LOT NUMBERS ARE READABLE ON THE COMPONENTS. DOI: (B)(6), 2018. DOR: (B)(6), 2024. AFFECTED SIDE : RIGHT KNEE.
Patient problems: Fall; Unspecified Infection
MAUDE report 18956239 ↗InjuryAug 4, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PATIENT WAS REVISED DUE TO PAINFUL KNEE. DOI: (B)(6) 2013; DOR: (B)(6) 2022; AFFECTED SIDE: RIGHT KNEE.
Patient problems: Pain
MAUDE report 15163627 ↗InjuryFeb 10, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PATIENT WAS REVISED DUE TO KNEE JOINT INFECTION. ALL IMPLANTS WERE REMOVED AND A SPACER WAS PLACED. DOI: (B)(6) 2017, DOR: (B)(6) 2022, AFFECTED SIDE: RIGHT KNEE.
Patient problems: Unspecified Infection
MAUDE report 13508034 ↗InjuryOct 15, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
QUESTIONS: 1. WAS THE CEMENT PRODUCT MANUFACTURED BY DEPUY? IF YES, PLEASE PROVIDE THE PART AND LOT NUMBERS AND QUANTITY OF THE CEMENT. 2. PLEASE CLARIFY, WAS THE PATELLAR IMPLANT REMOVED? 3. IT WAS INDICATED IN THE EVENT DESCRIPTION THAT PATIENT WAS REVISED WITH A THICKER POLY ON 3/10/20. WAS THIS BEING REPORTED? IF YES, PLEASE PROVIDE THE COMPLAINT NUMBER. 3.1. IF NONE REPORTED, PLEASE PROVIDE DETAILS OF THE PREVIOUS REVISION. 4. WAS INSTABILITY RELATED TO POLYETHYLENE WEAR? 5. WAS THERE ANY REPORTED MALPOSITION OF COMPONENTS THAT LED TO THE INSTABILITY? 6. WERE ANY COMPONENTS UNDERSIZED ON THE PRIMARY SURGERY THAT LED TO THE INSTABILITY? 7. WAS THE FEMUR OR TIBIA EXCESSIVELY RESECTED/JOINT LINE RAISED DURING THE PRIMARY SURGERY THAT LED TO THE INSTABILITY. ANSWERS: 1. UNKNOWN WHAT CEMENT. 2. PATELLA WAS RETAINED. 3. ORIGINAL CASE # WAS 168118 ( I AM ATTACHING THE MDR AS THERE IS NO COMPLAINT # ON IT. 5-7. NO OTHER THAN THAT, I HAVE NO FURTHER INFORMATION.
Patient problems: Joint Laxity
MAUDE report 12638397 ↗InjuryJun 9, 2021Loss of or Failure to Bond; Loss of or Failure to Bond
PATIENT HAD A LOOSE FEMUR AND EXPERIENCED INSTABILITY. DR. REPLACED IT WITH A TC3 FEMORAL REVISION WITH A PRESS FIT STEM AND SLEEVE SURGERY DELAY OF 75 MINUTES. PROCEDURE SUCCESSFULLY COMPLETED. PATIENT'S POLY AND PATELLA WERE WORN AND OXIDIZED. IT WAS REPLACED WITH AN AOX POLY ENCE.
Patient problems: Joint Laxity
MAUDE report 11968681 ↗InjuryOct 26, 2017Loss of or Failure to Bond; Loss of or Failure to Bond
THE PATIENT WAS REVISED TO ADDRESS LOOSENING OF THE FEMORAL AND TIBIAL COMPONENTS AT THE CEMENT TO IMPLANT INTERFACE. CEMENT MANUFACTURER IS UNKNOWN.
Patient problems: No Information
MAUDE report 6980129 ↗InjuryOct 18, 2017Insufficient Device Problem Information; Insufficient Device Problem Information
PATIENT WAS REVISED TO ADDRESS PAIN AND SUSPECTED FEMORAL LOOSENING. IT WAS ALSO STATED THAT FEMUR WAS STILL FIXED TO BONE. UPDATE SEP 18, 2017: DER REVIEWED FOR REPORTABILITY. NOTED THAT ALTHOUGH REVISED TO ADDRESS POSSIBLE FEMUR LOOSENING, INDICATED FEMUR FIXED TO BONE AND NO LOOSENING REPORTED. COMPLAINT UPDATED ON: OCT 17, 2017.
Patient problems: Pain
MAUDE report 6959319 ↗
Other Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices
- ATTUNE 1506-10-005Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing442 reports
- ATTUNE 1506-10-004Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing442 reports
- ATTUNE 1518-20-038Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing3 deaths393 reports
- LCS SIGMA 1294-33-130Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing1 recall310 reports
- ATTUNE 1518-20-035Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing342 reports
- P.F.C. SIGMA 96-0102Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing1 death319 reports
- ATTUNE 1518-20-041Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing308 reports
- ATTUNE 1506-10-007Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing284 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page