SIGMA AOX 1961-92-013Recalls & reported problems
Depuy Orthopaedics, Inc. · SIGMA TIBIAL INSERT ROTATING PLATFORM CURVED AOX SIZE 2 15mm · Class 3 · Implant
All models of SIGMA AOX (53)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10603295076100), received between Nov 12, 2019 and Nov 12, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “Unintended Movement” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Unintended Movement1
Patient problems
- No Code Available1
- Weakness1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryNov 12, 2019Unintended Movement; Unintended Movement
IT WAS REPORTED THAT THE PATIENT FELL AFTER SUCCESSFUL TKA. HER 2 X 15 SIGMA RP CR POLY SPUN OUT. CLOSED REDUCTION WAS ATTEMPTED WITHOUT SUCCESS. THE SURGEON REVISED THE POLY TO A 2 X 17.5 RP CR. DURING THIS PROCEDURE, IT WAS NOTED THAT THE PATIENT HAD SIGNIFICANT MCL TRAUMA. THE MCL WAS REPAIRED. THERE IS NO FURTHER INFO/XRAYS AVAIL AT THIS TIME. DOI: (B)(6) 2019; DOR: (B)(6) 2019; LEFT KNEE.
Patient problems: No Code Available; Weakness
MAUDE report 9310454 ↗
Other Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices
- ATTUNE 1506-10-005Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing442 reports
- ATTUNE 1506-10-004Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing442 reports
- ATTUNE 1518-20-038Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing3 deaths393 reports
- LCS SIGMA 1294-33-130Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing1 recall310 reports
- ATTUNE 1518-20-035Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing342 reports
- P.F.C. SIGMA 96-0102Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing1 death319 reports
- ATTUNE 1518-20-041Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing308 reports
- ATTUNE 1506-10-007Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing284 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.