The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 10603295080176), received between Feb 12, 2019 and Mar 12, 2025 — classified as 10 malfunctions.

The most frequently reported specific device problem is “Break” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break3
  • Device-Device Incompatibility3
  • Unintended Movement3
  • Material Twisted/Bent1
  • Positioning Problem1
  • Scratched Material1
  • Structural Problem1

Patient problems

  • No Consequences Or Impact To Patient5
  • No Clinical Signs, Symptoms or Conditions4
  • Insufficient Information1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 12, 2025Break; Break

    IT WAS REPORTED THAT THE BROACH HANDLE ATTACHMENT AND TRIAL EXTRACTOR BROKE DURING CLEANING.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21588024 ↗
  • MalfunctionJun 8, 2022Break; Break

    BROACH HANDLE BOLT BROKE. NO ADVERSE AFFECTS ON THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14633511 ↗
  • MalfunctionFeb 1, 2021Break; Break

    IT WAS REPORTED THAT AML BROACH HANDLE WAS BROKE ON THE END THAT GRABS THE BROACH AND WOULD NOT ATTACH TO BROACH. SNAPPED THE END OF IT OFF IN ONE PIECE. DELAYED THE CASE BY APPROXIMATELY 10 MINUTES.

    Patient problems: Insufficient Information

    MAUDE report 11262138 ↗
  • MalfunctionJan 13, 2021Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent

    IT WAS REPORTED THAT THE EXCEL BROACH DID NOT FULLY ENGAGE WITH HANDLE. THE HANDLE APPEARED TO BE WORN WHERE IT MEETS THE BROACH. IT WAS NOT USED IN SURGERY, AND SURGERY TIME WAS NOT EXTENDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11165499 ↗
  • MalfunctionDec 4, 2020Structural Problem; Structural Problem

    ADDITIONAL INFORMATION RECEIVED INDICATED THAT THE BROACH DID NOT OPEN OR CLOSE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10943979 ↗
  • MalfunctionJan 28, 2020Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED THAT THE BROACH HANDLE WOULD NOT ENGAGE IN SUMMIT BROACH. NO SURGICAL DELAY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9637785 ↗
  • MalfunctionOct 24, 2019Unintended Movement; Unintended Movement

    TIGHTEN SPRING MECHANISM.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9235854 ↗
  • MalfunctionOct 24, 2019Unintended Movement; Unintended Movement

    TIGHTEN SPRING MECHANISM.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9235853 ↗
  • MalfunctionOct 24, 2019Unintended Movement; Unintended Movement

    TIGHTEN SPRING MECHANISM.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9235845 ↗
  • MalfunctionFeb 12, 2019Device-Device Incompatibility; Positioning Problem; Scratched Material; Device-Device Incompatibility; Positioning Problem; Scratched Material

    IT WAS REPORTED THAT THE BROACH HANDLE POST LEVERED WOULD NOT LOCK INTO BROACH.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8332405 ↗