DELTA XTEND 2307-01-030Recalls & reported problems
Depuy (Ireland) · DELTA Xtend BROACH HANDLE · Class 1
All models of DELTA XTEND (194)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10603295115502), received between Jun 16, 2020 and Dec 22, 2021 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
- Device-Device Incompatibility1
- Unintended Movement1
Patient problems
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 22, 2021Unintended Movement; Unintended Movement
IT WAS REPORTED THAT THIS WAS AN UNKNOWN PROCEDURE PERFORMED ON (B)(6) 2021. EVERY TIME THEY USED THE HANDLE, THE ¿BALL JOINT¿ WHERE THE 230701031 GONIOMETER IS MOUNTED HAD COME LOOSER. THERE WAS NO SURGICAL DELAY AND NO HARM TO THE PATIENT. [ANSWER TO PCF] WITH REGARDS TO THIS, PLEASE CONFIRM IF ANY OF THE FOLLOWING INFORMATION IS AVAILABLE: PLEASE PROVIDE VALID LOT NUMBER FOR DELTAXTEND BROACH HANDLE (230701030).: LOT # 5335312/ SERIAL # (B)(4). PLEASE VERIFY IF THE PRODUCT IS AVAILABLE FOR RETURN OR NOT? THE DEVICE CURRENTLY IN OUR HANDS WILL BE RETURNED TO YOU.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13061318 ↗MalfunctionAug 20, 2021Device-Device Incompatibility; Device-Device Incompatibility
DURING GLOBAL ANATOMIC TSR IT WAS DISCOVERED THAT THE SIZE 48 GLENOID TRIAL HAD A LARGE CRACK THROUGH IT. FURTHERMORE THE TRIAL STEM INTRODUCER FAILED TO ENGAGE WITH THE NECK COMPONENTS DESPITE ATTEMPTS TO MANIPULATE IT DURING AND AFTER THE CASE.
Patient problems: Insufficient Information
MAUDE report 12348312 ↗MalfunctionJun 16, 2020Break; Break
IT WAS REPORTED THAT THE BROACH HANDLE WAS BROKEN DURING SURGERY. NO SURGICAL DELAY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10158076 ↗
Other BROACH devices
- NA 2598-07-550Depuy (Ireland) · BROACH323 reports
- SUMMIT 2570-00-000Depuy (Ireland) · BROACH269 reports
- NA 952212500FDepuy (Ireland) · BROACH245 reports
- ACTIS 2010-01-050Depuy (Ireland) · BROACH235 reports
- CORAIL 9522-11-500Depuy (Ireland) · BROACH210 reports
- ACTIS 2010-01-060Depuy (Ireland) · BROACH186 reports
- ACTIS 2010-01-040Depuy (Ireland) · BROACH172 reports
- ACTIS 2010-01-070Depuy (Ireland) · BROACH162 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.