S-ROM 2576-02-025Recalls & reported problems
Depuy Orthopaedics, Inc. · S-ROM TRIPLE BAND CONE REAMER SIZE 25 · Class 1
All models of S-ROM (92)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 10603295145370), received between Nov 7, 2019 and Nov 9, 2023 — classified as 7 malfunctions.
The most frequently reported specific device problem is “Illegible Information” (6 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Illegible Information6
- Naturally Worn3
- Material Discolored2
- Material Twisted/Bent2
- Contamination /Decontamination Problem1
- Dull, Blunt1
Patient problems
- No Consequences Or Impact To Patient5
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 9, 2023Material Discolored; Naturally Worn; Illegible Information; Material Discolored; Naturally Worn; Illegible Information
IT WAS REPORTED THAT THE INSTRUMENTS SIZING AND COLOR MARKINGS ARE FADED, WORN AND DIFFICULT TO SEE. DID NOT HAPPEN DURING SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18101338 ↗MalfunctionApr 5, 2023Material Discolored; Naturally Worn; Illegible Information; Material Discolored; Naturally Worn; Illegible Information
IT WAS REPORTED THAT THE SIZING MARKERS ARE TOO FADED AND WORN. THEY ARE DIFFICULT TO READ. THERE WAS NO SURGICAL DELAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16681680 ↗MalfunctionApr 27, 2020Material Twisted/Bent; Illegible Information; Material Twisted/Bent; Illegible Information
IT WAS REPORTED THAT THESE INSTRUMENTS HAVE EXCESSIVE WEAR AND ARE DIFFICULT TO READ. REP INDICATED "THAT THEY NEED TO BE REPLACED". NO SURGICAL DELAY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10002010 ↗MalfunctionApr 27, 2020Naturally Worn; Illegible Information; Naturally Worn; Illegible Information
IT WAS REPORTED THAT WEAR AND TEAR, UNABLE TO READ IN SURGERY. SALES REPRESENTATIVE INDICATED NEED FOR REPLACEMENT. NO SURGICAL DELAY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10000541 ↗MalfunctionMar 24, 2020Illegible Information; Illegible Information
IT WAS REPORTED THAT SROM INSTRUMENTS ARE DIFFICULT OR IMPOSSIBLE TO READ THE SIZING. SURGEON IS CONCERNED THIS IS A PATIENT SAFETY ISSUE AND INSTRUMENTS SHOULD BE REPLACED. NO SURGICAL DELAY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9875132 ↗MalfunctionFeb 20, 2020Material Twisted/Bent; Illegible Information; Material Twisted/Bent; Illegible Information
IT WAS REPORTED THAT THE INSTRUMENT WERE DIFFICULT OR IMPOSSIBLE TO READ ETCHING DUE TO WEAR AND TEAR OVER THE YEARS. THE SURGEON IS CONCERNED ABOUT THE PATIENT SAFETY ISSUE AND THE INSTRUMENTS NEED TO BE REPLACED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9732493 ↗MalfunctionNov 7, 2019Dull, Blunt; Contamination /Decontamination Problem; Dull, Blunt; Contamination /Decontamination Problem
FOUND A CONTAMINANT WHITE POWDERY SUBSTANCE ON THEIR SROM HIP INSTRUMENTS FOLLOWING THE WASH CYCLE. IT AFFECTED MULTIPLE INSTRUMENTS ¿ PRIMARILY STEM TRIALS THAT ARE ALUMINIUM BASED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9290346 ↗
Other REAMER devices
- QUICKSET 2440-00-551Depuy (Ireland) · REAMER1,150 reports
- QUICKSET 2440-00-549Depuy (Ireland) · REAMER1,113 reports
- QUICKSET 2440-00-553Depuy (Ireland) · REAMER1,105 reports
- QUICKSET 2440-00-547Depuy (Ireland) · REAMER1,073 reports
- QUICKSET 2440-00-555Depuy (Ireland) · REAMER1,065 reports
- QUICKSET 2440-00-557Depuy (Ireland) · REAMER1,031 reports
- QUICKSET 2440-00-545Depuy (Ireland) · REAMER947 reports
- QUICKSET 2440-00-552Depuy (Ireland) · REAMER888 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page