P.F.C. SIGMA 95-1031Recalls & reported problems

Depuy (Ireland) · P.F.C. SIGMA TIBIAL INSERT ROTATING PLATFORM RP-F SIZE 3 12.5mm GVF · Class 3 · Implant

All models of P.F.C. SIGMA (487)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10603295230380), received between Jan 14, 2022 and Dec 16, 2025 — classified as 4 injuries.

The most frequently reported specific device problem is “Naturally Worn” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Naturally Worn1

Patient problems

  • Joint Laxity2
  • Bone Notching1
  • Fall1
  • Pain1
  • Unspecified Infection1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 16, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT PFC SIG RPF INS SZ 3 12.5MM, UNKNOWN KNEE TIBIAL TRAY, AND UNKNOWN KNEE FEMORAL WERE INVOLVED IN A REPORTED EVENT DURING A TOTAL KNEE ARTHROPLASTY PROCEDURE. THE PATIENT HAD A HISTORY OF MULTIPLE FALLS AND POSSIBLE JOINT INSTABILITY. DURING REVISION SURGERY, THE FEMUR AND TIBIA WERE FOUND TO BE WELL FIXED WITH GOOD BONE AND CEMENT INTEGRATION, AND THE POLY INSERT DID NOT SHOW ABNORMAL WEAR OR OSTEOLYSIS. EXTENSION AND FLEXION WERE OPENING APPROXIMATELY 3-4MM EACH, AND THERE WAS EXCESSIVE BONE GROWTH OVER THE PATELLA AND TIBIAL BASE PLATE. THE FEMUR, TIBIA, AND POLY INSERT WERE REMOVED, WHILE THE ORIGINAL DOME PATELLA REMAINED UNTOUCHED. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT DELAY, NO FRAGMENTS WERE GENERATED, AND NO ADDITIONAL MEDICAL INTERVENTION WAS REQUIRED. ALL THREE DEVICES WERE EXPLANTED DURING THE PROCEDURE.

    Patient problems: Bone Notching; Fall; Joint Laxity

    MAUDE report 23818839 ↗
  • InjuryJul 16, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT UNDERWENT POLY WASHOUT AND REPLACEMENT DUE TO PAIN.

    Patient problems: Pain

    MAUDE report 22519295 ↗
  • InjuryDec 8, 2022Naturally Worn; Naturally Worn

    PATIENT REQUIRED REVISION KNEE SURGERY FOR AN UNSTABLE TIBIAL INSERT & WORN PATELLA. ON OPENING THE JOINT, THE PATELLA SHOWED SOME WEAR & YELLOW DISCOLORATION INDICATIVE OF POLY WEAR. WHEN THE JOINT WAS DISTRACTED MEDICALLY, THERE WAS SOME GAPPING. ON REMOVAL OF TIBIAL INSERT IT ALSO SHOWED SOME WEAR ON THE POSTERIOR MEDIAL SIDE. A NEW INSERT & PATELLA IMPLANT WERE INSERTED. PATIENT HAD GOOD ROM & WAS STABLE AT CONCLUSION OF SURGERY

    Patient problems: Joint Laxity

    MAUDE report 15939623 ↗
  • InjuryJan 14, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT UNDERWENT THE SURGERY WITH RPF INSERT IN QUESTION. AFTER THE SURGERY IT WAS CONFIRMED THAT A PERIPROSTHETIC JOINT INFECTION OCCURRED. REMOVAL SURGERY WAS PERFORMED.

    Patient problems: Unspecified Infection

    MAUDE report 13261894 ↗

Other Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices

All Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices →