P.F.C. SIGMA 96-0889Recalls & reported problems
Depuy (Ireland) · P.F.C. SIGMA DISTAL AUGMENT COMBO SIZE 4 12mm LEFT · Class 3 · Implant
All models of P.F.C. SIGMA (487)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10603295234425), received between May 11, 2021 and Sep 7, 2021 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Pain2
- Joint Laxity1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjurySep 7, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PATIENT WAS REVISED DUE TO INSTABILITY AND PAIN. SURGEON NOTED LOOSENING OF THE PFC SIGMA FEMORAL ADAPTER AND PFC SIGMA BOLT. THE BOLT BROKE AND DISASSOCIATED FROM THE ADAPTER. THE FEMUR WAS EASILY REMOVED AND THE ADAPTER WAS TURNED LOOSE. THE REMAINING BOLT WAS REMOVED FROM THE EXISTING FEMORAL SLEEVE VIA A THREADED EXTRACTOR IN THE REVISION KNEE REMOVAL SYSTEM. ALL COMPONENTS WERE REMOVED. THE SURGEON THEN SUCCESSFULLY COMPLETED CONVERTING TO A HINGE FEMUR. PATIENT HAD EXISTING TC3 REVISION CONSTRUCT IN LEFT KNEE. DOI: (B)(6) 2017, DOR: (B)(6) 2021, LEFT KNEE.
Patient problems: Joint Laxity; Pain
MAUDE report 12437023 ↗InjuryMay 11, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS REVISED TO ADDRESS PAIN AND POSSIBLE ROTATION OF IMPLANTS. NO LOOSENING WAS REPORTED. DOI: (B)(6) 2019, DOR: (B)(6) 2021, LEFT KNEE.
Patient problems: Pain
MAUDE report 11804830 ↗
Other Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices
- ATTUNE 1506-10-005Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing442 reports
- ATTUNE 1506-10-004Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing442 reports
- ATTUNE 1518-20-038Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing3 deaths393 reports
- LCS SIGMA 1294-33-130Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing1 recall310 reports
- ATTUNE 1518-20-035Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing342 reports
- P.F.C. SIGMA 96-0102Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing1 death319 reports
- ATTUNE 1518-20-041Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing308 reports
- ATTUNE 1506-10-007Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing284 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.