CORAIL L93205Recalls & reported problems

Depuy (Ireland) · CORAIL AMT PROXIMAL COMPACTOR · Class 1

Adverse event reports
12
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 12 adverse event reports that list this exact device (DI 10603295260707), received between Oct 23, 2018 and Sep 3, 2025 — classified as 12 malfunctions.

The most frequently reported specific device problem is “Break” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break4
  • Naturally Worn4
  • Contamination /Decontamination Problem2
  • Insufficient Device Problem Information1
  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7
  • No Consequences Or Impact To Patient5
  • Insufficient Information1

Recent adverse event reports

The 12 most recent of 12 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 3, 2025Contamination /Decontamination Problem; Contamination /Decontamination Problem

    IT WAS REPORTED THAT DURING THE STERILIZATION PROCESS CARRIED OUT AT THE HOSPITAL, A DARK LIQUID WAS RELEASED FROM THE IMPACTOR (SUSPECTED TO BE FROM THE CABLE). THE SCHEDULED SURGERY THAT WOULD USE THIS MATERIAL HAD TO BE CANCELED AND RESCHEDULED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22952076 ↗
  • MalfunctionNov 13, 2024Contamination /Decontamination Problem; Contamination /Decontamination Problem

    IT WAS REPORTED THAT PRIOR TO A PROCEDURE ON (B)(6) 2024, A BONE IMPACTOR WOODEN HANDLE HAD LEACHED COLOUR ONTO THE TRAY DURING/AFTER STERILISATION. THE HOSPITAL DECIDED IT WAS STILL CONSIDERED STERILE, SO STILL USED THE SET.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 20677633 ↗
  • MalfunctionApr 5, 2024Break; Break

    THE HANDLE WAS REPORTED BROKEN BY THE MEDICAL DEVICE REPROCESSING DEPARTMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19050374 ↗
  • MalfunctionNov 6, 2023Naturally Worn; Naturally Worn

    IT WAS REPORTED THAT INSTRUMENTS NEED REPLACING DUE TO WEAR AND TEAR AND ARE NO LONGER USABLE FOR SURGERY. THERE WAS NO ADVERSE EFFECT TO THE PATIENT OR SURGERY

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18081021 ↗
  • MalfunctionMar 27, 2023Naturally Worn; Naturally Worn

    IT WAS REPORTED THAT BONE IMPACTOR IS BLUNT. OVER 10 YEARS USE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16620518 ↗
  • MalfunctionMar 6, 2023Break; Break

    THE BONE IMPACTOR HANDLE BROKE DURING ITS USE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16490958 ↗
  • MalfunctionMar 11, 2022Break; Break

    HOSPITAL HAS COMMUNICATED THAT SEVERAL ITEMS NEEDED TO BE REPLACED DUE TO WEAR AND TEAR/ BREAKAGE. CORAIL IMPACTOR - BROKEN IN TWO PIECES WHEN IMPACTED. X2 FRAGMENTS. SCREW DRIVER NOT GRIPPING SCREW DUE TO WEAR AND TEAR. TRIAL HEADS - CAN'T READ SIZES DUE TO WEAR AND TEAR. NO REPORTED PATIENT CONSEQUENCES OR SURGICAL DELAYS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13733428 ↗
  • MalfunctionMay 22, 2019Break; Break

    THE PART WHERE THE INSTRUMENT BROKE WAS AT THE RESIN SLEEVE AND WAS BROKEN INTO MANY FRAGMENTS. THE EVENT OCCURRED POST OP, AFTER THE DEVICE WAS TAKEN OUT OF THE CLEANING MACHINE, DETECTED DURING THE PACKAGING PROCESS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8633800 ↗
  • MalfunctionMay 22, 2019Naturally Worn; Naturally Worn

    ITEM WAS FLAGGED DURING THE STERILISATION PROCESS. NO ADVERSE EVENT REPORTED. NO FURTHER INFORMATION WAS PROVIDED. AFTER EVALUATION THE IMPACTOR WAS DETERMINED TO BE WORN.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8631697 ↗
  • MalfunctionFeb 12, 2019Naturally Worn; Naturally Worn

    MDR STAFF HAS INDICATED PRODUCT L93606 (BONE TAMP IMPACTOR) WAS WORN AND DAMAGED. THE HANDLE WAS FOUND TO BE CRACKED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8332566 ↗
  • MalfunctionNov 1, 2018Material Deformation; Material Deformation

    IT WAS REPORTED THAT THEY RECEIVED A CALL FROM THEIR LOCAL AGENT. IT WAS INDICATED THAT HE WILL LOG A PRODUCT COMPLAINT ABOUT THE PLC HOSPITAL SENDING DEPUY SYNTHES CONSIGNED INSTRUMENTATION AT A 3RD PARTY VENDOR FOR ¿SHARPENING¿ WITHOUT THEIR KNOWLEDGE OR APPROVAL.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8027816 ↗
  • MalfunctionOct 23, 2018Insufficient Device Problem Information; Insufficient Device Problem Information

    INSTRUMENT WEAR.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7994647 ↗

Other IMPACTOR devices

All IMPACTOR devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.