RECLAIM 34-235-0018Recalls & reported problems
Depuy (Ireland) · RECLAIM MONOBLOC – REVISION HIP SYSTEM DISTAL REAMER LONG 18 · Class 1
All models of RECLAIM (149)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10603295536253), received between Mar 16, 2026 and Mar 16, 2026 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 16, 2026Break
IT WAS REPORTED THAT DURING A TOTAL HIP REPLACEMENT PROCEDURE, THE RECLAIM DIST REAMER 18 LONG BECAME STUCK IN THE FEMORAL CANAL INTRAOPERATIVELY, REQUIRING AN EXTENDED EFFORT OF 45 MINUTES USING A REAMER EXTRACTOR AND SLAP HAMMER BEFORE REMOVAL WAS ACHIEVED. THE SURGERY WAS DELAYED DUE TO THIS EVENT, BUT ULTIMATELY COMPLETED. FRAGMENTS WERE GENERATED AND REMOVED EASILY WITHOUT ADDITIONAL INTERVENTION. THE EVENT INVOLVED A HIP REVISION, AND SURGICAL INTERVENTION WAS REQUIRED.
Patient problems: Insufficient Information
MAUDE report 24604668 ↗
Other REAMER devices
- QUICKSET 2440-00-551Depuy (Ireland) · REAMER1,150 reports
- QUICKSET 2440-00-549Depuy (Ireland) · REAMER1,113 reports
- QUICKSET 2440-00-553Depuy (Ireland) · REAMER1,105 reports
- QUICKSET 2440-00-547Depuy (Ireland) · REAMER1,073 reports
- QUICKSET 2440-00-555Depuy (Ireland) · REAMER1,065 reports
- QUICKSET 2440-00-557Depuy (Ireland) · REAMER1,031 reports
- QUICKSET 2440-00-545Depuy (Ireland) · REAMER947 reports
- QUICKSET 2440-00-552Depuy (Ireland) · REAMER888 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page