INHANCE 5200-01-032Recalls & reported problems
Depuy (Ireland) · INHANCE SHOULDER SYSTEM SHORT STEM SMALL diameter 32mm X 70mm · Class 2 · Implant
All models of INHANCE (200)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10603295538219), received between Dec 12, 2024 and Sep 15, 2025 — classified as 3 injuries.
The most frequently reported specific device problem is “Loss of or Failure to Bond” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Loss of or Failure to Bond1
- Osseointegration Problem1
Patient problems
- Bone Fracture(s)1
- Hematoma1
- Inadequate Osseointegration1
- Insufficient Information1
- Unspecified Infection1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjurySep 15, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT WAS REVISED DUE TO PERI PROSTHETIC FRACTURE. AFFECTED SIDE: LEFT SHOULDER.
Patient problems: Bone Fracture(s)
MAUDE report 23053002 ↗InjuryJul 31, 2025Osseointegration Problem; Osseointegration Problem
IT WAS REPORTED THAT THE PATIENT DEVELOPED A HEMATOMA. THE SURGEON WAS GOING TO REPLACE THE POLY IN CASE OF INFECTION. WHILE REMOVING THE POLY, THE STEM HAD A LITTLE MOVEMENT. THE SURGEON REMOVED IT AND REPLACED THE STEM, SHELL AND POLY. DOI: (B)(6) 2025, DOR: (B)(6) 2025, AFFECTED SIDE: RIGHT SHOULDER.
Patient problems: Hematoma; Inadequate Osseointegration; Unspecified Infection
MAUDE report 22682676 ↗InjuryDec 12, 2024Loss of or Failure to Bond; Loss of or Failure to Bond
IT WAS REPORTED THAT THE PATIENT WAS REVISED FOR LOOSE GLENOID AND STEM. THERE WAS NO SURGICAL DELAY. DOI: (B)(6) 2024, DOR: (B)(6) 2024 AND AFFECTED SIDE: LEFT SHOULDER.
Patient problems: Insufficient Information
MAUDE report 20920451 ↗
FDA clearance and classification
The FDA regulates product code PAO (prosthesis, shoulder, semi-constrained, metal/polymer + additive, cemented) under 21 CFR 888.3660 as a Class II device. 21 CFR 888.3660 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the INHANCE 5200-01-032
Has the INHANCE 5200-01-032 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10603295538219), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the INHANCE 5200-01-032?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Dec 12, 2024 and Sep 15, 2025. In those reports, the most common specific device problems are “Loss of or Failure to Bond” (1) and “Osseointegration Problem” (1); the most common patient problems are “Bone Fracture(s)” (1), “Hematoma” (1) and “Inadequate Osseointegration” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the INHANCE 5200-01-032?
None of the reports are classified as deaths, 3 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the INHANCE 5200-01-032 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the INHANCE 5200-01-032, and is it still sold?
The FDA's device database lists Depuy (Ireland) as the company responsible for it (brand INHANCE, model 5200-01-032). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other prosthesis, shoulder, semi-constrained, metal/polymer + additive, cemented devices
- Comprehensive Reverse Shoulder 115310Biomet Orthopedics, LLC · prosthesis, shoulder, semi-constrained, metal/polymer + additive, cemented1 death96 reports
- INHANCE 5120-00-110Depuy (Ireland) · prosthesis, shoulder, semi-constrained, metal/polymer + additive, cemented71 reports
- Comprehensive® Reverse Shoulder XL-115364Biomet Orthopedics, LLC · prosthesis, shoulder, semi-constrained, metal/polymer + additive, cemented1 recall7 reports
- Comprehensive® Reverse Shoulder XL-115366Biomet Orthopedics, LLC · prosthesis, shoulder, semi-constrained, metal/polymer + additive, cemented1 recall4 reports
- Comprehensive® Reverse Shoulder 180550Biomet Orthopedics, LLC · prosthesis, shoulder, semi-constrained, metal/polymer + additive, cemented2 deaths43 reports
- DJO SURGICAL 521-07-246Encore Medical, L.P. · prosthesis, shoulder, semi-constrained, metal/polymer + additive, cemented42 reports
- Comprehensive® Reverse Shoulder 180551Biomet Orthopedics, LLC · prosthesis, shoulder, semi-constrained, metal/polymer + additive, cemented42 reports
- Comprehensive® 110031399Zimmer, Inc. · prosthesis, shoulder, semi-constrained, metal/polymer + additive, cemented1 death36 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page