CUPTIMIZE Advanced 4515-80-070Recalls & reported problems
Depuy (Ireland) · CUPTIMIZE Advanced Windows · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10603295552093), received between Jul 16, 2024 and Jul 16, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Computer Software Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Computer Software Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 16, 2024Computer Software Problem; Computer Software Problem
IT WAS REPORTED THAT THE SAME GLITCH OCCURRED WITH THE INCLINATION JUMPING UP 4-5MM AFTER ACCEPTING A NEW IMAGE. IT WAS RECOGNIZED IMMEDIATELY. THE SURGEON GOT THE FINAL CUP POSITION THAT HE WANTED 37/17. HE SEATED IT. HE TOOK ONE MORE SHOT AFTER SEATING THE CUP COMPLETELY. THE IMAGE WAS ACCEPTED AND MOVED TO THE ANALYSIS SCREEN. THE ELLIPSE SIZE DID NOT CHANGE BUT OBSERVED THE INCLINATION JUMP FROM 7 TO 42. ALSO WHEN I TRIED TO CHANGE THE CONTRAST ON BOTH THE AP PELVIS AND AP HIP X-RAYS THEY BOTH QUICKLY WENT DARK AND WAS UNABLE TO ADJUST. HAD TO X OUT OF THAT SCREEN AND START OVER WITH NEW X-RAY THEN JUST ACCEPT IT AS IT SHOWED UP. SURGERY WAS NOT DELAYED DUE TO THE REPORTED EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19750703 ↗
Other System, image processing, radiological devices
- Interventional Workspot Interventional Workspot - 1Philips Medical Systems Nederland B.V. · System, Image Processing, Radiological13 recalls24 reports
- Synapse Radiology PACS Synapse Radiology PACS Software LicenseFujifilm Healthcare Americas Corporation · System, image processing, radiological9 recalls38 reports
- CENTRICITY UNIVERSAL VIEWER ZFP CLIENT 6.0Ge Healthcare · System, image processing, radiological8 recalls0 reports
- CENTRICITY UNIVERSAL VIEWER 6.0Ge Healthcare · System, image processing, radiological8 recalls0 reports
- CENTRICITY UNIVERSAL VIEWER 7.0Ge Healthcare · System, image processing, radiological6 recalls0 reports
- IntelliSpace Cardiovascular 8Philips Medical Systems Nederland B.V. · System, Image Processing, Radiological2 recalls132 reports
- CA1000 2.0 SP 14Ge Healthcare · System, image processing, radiological4 recalls0 reports
- VMA 2Ortho Kinematics, Inc. · System, Image Processing, Radiological4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page