CADD 21-2160-51Recalls & reported problems
Icu Medical, Inc. · Class 2
All models of CADD (123)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 16
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 16 adverse event reports that list this exact device (DI 10610586031212), received between Jan 8, 2020 and Nov 24, 2025 — classified as 16 malfunctions.
The most frequently reported specific device problem is “Battery Problem” (5 reports).
7 other recalls cover devices cleared under the same FDA submission (K072144); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Battery Problem5
- Charging Problem4
- Failure to Charge3
- Complete Loss of Power2
- Pumping Stopped2
- Crack1
- Failure to Infuse1
Patient problems
- No Consequences Or Impact To Patient8
- No Clinical Signs, Symptoms or Conditions6
- No Information2
Recent adverse event reports
The 16 most recent of 16 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 24, 2025Failure to Charge; Failure to Charge
IT WAS REPORTED THAT THE PUMP RETURNED FROM CLINICAL USE AND CONNECTED TO AC CABLE TO CHARGE. PUMP SWITCHED ON, ON-SCREEN ALARM ¿BATTERY DEPLETED PUMP WILL NOT RUN¿ BATTERY INDICATOR AT 0 PERCENT. BATTERY REMOVED FROM PUMP AND INSERTED INTO THREE DIFFERENT PROVEN FUNCTIONING DEVICES, SAME ALARM ON EACH OCCASION. ON INSPECTION BATTERY INDICATOR WAS ILLUMINATING GREEN. BATTERY PACK INSERTED INTO FOUR DIFFERENT FUNCTIONING PUMPS, ALL FAILED WITH ¿BATTERY DEPLETED PUMP WILL NOT RUN¿ BATTERY INDICATOR AT 0 PERCENT. EVENT OCCURRED AT HOSPITAL DURING PRE-TEST.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23636428 ↗MalfunctionJun 3, 2025Failure to Infuse; Failure to Infuse
IT WAS REPORTED THAT THE PUMP DISPLAYED ¿BATTERY DEPLETED. PUMP WILL NOT RUN¿ ALERT AND THE ALARM WAS SOUNDING. UNABLE TO PROCEED WITH PUMP SET UP. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22137284 ↗MalfunctionMar 14, 2025Crack; Crack
IT WAS REPORTED THAT THE RECHARGEABLE BATTERY PACK HOUSING IS CRACKED OR DAMAGED. THE RESULTS OF THE INVESTIGATION FOUND THAT THE BATTERIES LOOKED TO BE IN POOR CONDITION WITH VISIBLE CRACKS SEEN ON SOME OF THE BATTERIES IN THE PICTURES. THERE WAS NO PATIENT INVOLVEMENT, AND NO PATIENT HARM/ADVERSE EVENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21610032 ↗MalfunctionDec 22, 2023Battery Problem; Battery Problem
IT WAS REPORTED THAT THE BATTERIES WERE UNDER LOW TENSION AND NO LONGER CHARGING. PER REPORTER WHEN THE PUMP WAS CONNECTED AND STARTED TO THE PATIENT FOR CHEMOTHERAPY TREATMENT AT THE HOSPITAL, IT CAUSED THE DEVICE TO EXHIBIT LOW BATTERY ALARM. ADDITIONALLY, THE BATTERY HAD RECENTLY BEEN RECHARGED BEFORE USE. NO ADVERSE PATIENT EFFECTS WERE REPORTED BY THE CUSTOMER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18388662 ↗MalfunctionDec 22, 2023Battery Problem; Battery Problem
IT WAS REPORTED THAT THE BATTERIES WERE UNDER LOW TENSION AND NO LONGER CHARGING. PER REPORTER WHEN THE PUMP WAS CONNECTED AND STARTED TO THE PATIENT FOR CHEMOTHERAPY TREATMENT AT THE HOSPITAL, IT CAUSED THE DEVICE TO EXHIBIT LOW BATTERY ALARM. ADDITIONALLY, THE BATTERY HAD RECENTLY BEEN RECHARGED BEFORE USE. NO ADVERSE PATIENT EFFECTS WERE REPORTED BY THE CUSTOMER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18383132 ↗MalfunctionAug 31, 2022Battery Problem; Battery Problem
IT WAS REPORTED THAT THE BATTERY DOES NOT CHARGE FULLY. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15329168 ↗MalfunctionOct 27, 2020Complete Loss of Power; Complete Loss of Power
INFORMATION WAS RECEIVED INDICATING THAT A SMITHS MEDICAL BATTERY PACK WAS IMPLICATED IN A PUMP ALARMING AND POWERING DOWN FOR NO REASON. THE PUMPS ARE BEING USED FOR A PEDIATRIC CLINICAL TRIAL. THERE WERE NO ADVERSE EVENTS REPORTED.
Patient problems: No Information
MAUDE report 10740102 ↗MalfunctionOct 26, 2020Complete Loss of Power; Complete Loss of Power
INFORMATION WAS RECEIVED INDICATING THAT A SMITHS MEDICAL BATTERY PACK IS IMPLICATED IN AN ISSUE WHERE THE PUMP ALARMED AND THEN POWERED DOWN FOR NO REASON. THE PUMP WAS BEING USED FOR A PEDIATRIC CLINICAL TRIAL. THERE WERE NO REPORTED ADVERSE EVENTS.
Patient problems: No Information
MAUDE report 10734974 ↗MalfunctionJul 15, 2020Failure to Charge; Pumping Stopped; Failure to Charge; Pumping Stopped
INFORMATION RECEIVED THAT A SMITHS MEDICAL CADD SOLIS BATTERY PACK MAY HAVE CAUSED THE PUMP TO ALARM LOW BATTERY EVEN THOUGH IT WAS PLUGGED. THE REPORTER ALSO STATED THAT THE BATTERY WOULD NOT CHARGE UP. THERE WERE NO CLINICAL CONSEQUENCE DUE TO THE REPORTED EVENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10279534 ↗MalfunctionJul 10, 2020Failure to Charge; Pumping Stopped; Failure to Charge; Pumping Stopped
INFORMATION RECEIVED THAT A SMITHS MEDICAL CADD SOLIS BATTERY PACK MAY HAVE CAUSED THE PUMP TO ALARM LOW BATTERY EVEN THOUGH IT WAS PLUGGED. THE REPORTER ALSO STATED THAT THE BATTERY WOULD NOT CHARGE UP. THERE WERE NO CLINICAL CONSEQUENCE DUE TO THE REPORTED EVENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10257970 ↗MalfunctionApr 14, 2020Battery Problem; Battery Problem
INFORMATION WAS RECEIVED INDICATING THAT A SMITHS MEDICAL RECHARGEABLE BATTERY PACK WOULD NOT GET FULLY CHARGED; IT ONLY ACCEPTED 75%. THE ISSUE OCCURRED DURING A PROCEDURE AND THERE WAS NO REPORTED IMPACT ON PATIENT OUTCOME.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9960088 ↗MalfunctionApr 14, 2020Battery Problem; Battery Problem
INFORMATION WAS RECEIVED INDICATING THAT A SMITHS MEDICAL RECHARGEABLE BATTERY PACK WOULD NOT GET FULLY CHARGED; IT ONLY ACCEPTED 75%. THE ISSUE OCCURRED DURING A PROCEDURE AND THERE WAS NO REPORTED IMPACT ON PATIENT OUTCOME.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9960085 ↗MalfunctionJan 8, 2020Charging Problem; Charging Problem
INFORMATION RECEIVED A SMITHS MEDICAL CADD ASSESSORIES BATTERY WILL ONLY CHARGE AND ACCEPT 75%. THIS IS CORRECTION AS THIS IS CHANGED TO NON REPORTABLE AS IT IS A BATTERY ACCESSORY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9566611 ↗MalfunctionJan 8, 2020Charging Problem; Charging Problem
REPORT FILED REPORTABLE AS THIS A CADD ACCESSORY AND BATTERY LITHIUM NOT CHARGING 75% IS NOT REPORTABLE . CORRECTION BEING SUBMITTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9565750 ↗MalfunctionJan 8, 2020Charging Problem; Charging Problem
CORRECTION BEING MADE ON MDR FILE. SUMMARY IN H 10.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9565742 ↗MalfunctionJan 8, 2020Charging Problem; Charging Problem
CORRECTION BEING MADE ON MDR FILE. SUMMARY IN H 10.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9565735 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K072144. One submission often covers many models, so check the product and lot details in each record.
- Z-1667-2025 · Apr 10, 2025 · Open, ClassifiedCADD-Solis HPCA Ambulatory Infusion Pump; Model/Number: 21-2111-0402-09-KYO 21-2111-0402-09-KYO CADD SOLIS PIB PUMP FOR CLINICAL EVALUATION/DEMO PUMP 21-2111-0300-09_LOAN CADD SO
- Z-2419-2024 · Feb 27, 2024 · Open, ClassifiedCADD-Solis Ambulatory Infusion Pumps, Model 2100. Intended for the following uses: Indicated for the following uses: Intra-arterial, subcutaneous, intraperitoneal, in close proximi
- Z-1813-2015 · May 26, 2015 · TerminatedCADD- Solis Ambulatory Infusion Pump, Model 2111 & 2112, Version 1.0, Version 2.0 and Version 3.0 & Model 2120, Version 1.0. Provide measured drug therapy to patients in hospita
- Z-0166-2015 · Sep 29, 2014 · TerminatedCADD-Solis Medication Safety Software, Administrator CD, Version 3.1, REF 21-2194-0301-01. Product Usage: The CADD-Solis Medication Safety Software- Administrator allows use of a
- Z-0004-2012 · May 10, 2011 · TerminatedSmiths Medical, CADD-Solis ambulatory infusion pumps, Models 2100, REF 21-2101-0200-51 and 2110, REF 21-2111-0100-51, Rx Only. Indicated for intravenous, intra-arterial, subcuta
- Z-1033-2011 · Jan 13, 2011 · TerminatedSmiths Medical, CADD-Solis Ambulatory Infusion Pump, Model Number: 2100 and 2110, Reorder Number 21-2101-00, 21-2101-0100-50, 21-2101-0100-51, 21-2101-0200-02, 21-2101-0200-03, 21-
- Z-1082-2010 · Jan 27, 2010 · TerminatedElectri-Cord AC Power Cords, IEC 60320 Coupler, Product Reorder Number 21-2145-01 only for use with Smiths Medical CADD-Solis ambulatory infusion pumps, Model 2100. These cords we
Other Pump, infusion, pca devices
- Alaris 8120Carefusion 303, Inc. · Pump, infusion, pca2 recalls4 deaths14,640 reports
- CADD 21-2111-0402-51Icu Medical, Inc. · Pump, infusion, pca4 recalls1,535 reports
- CADD 21-2111-0300-01Icu Medical, Inc. · Pump, infusion, pca1 recall1,116 reports
- Alaris™ PCA Module, Model 8120Carefusion 303, Inc. · Pump, infusion, pca2 recalls1 death917 reports
- Nimbus II PlusInfutronix LLC · Pump, Infusion, Pca1 recall1 death800 reports
- CADD 21-2112-0300-01Icu Medical, Inc. · Pump, infusion, pca1 recall406 reports
- CADD 21-6300-51Icu Medical, Inc. · Pump, infusion, pca414 reports
- Nimbus II PainPROInfutronix LLC · Pump, Infusion, Pca2 recalls186 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page