Halyard 35215Recalls & reported problems
Avanos Medical, Inc. · ENDOTRACHEAL TUBE EYE-7.5MM ORAL/NASAL MAGILL MURPHY MCUFF · Class 2
All models of Halyard (232)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 11
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 10680651352153), received between Jul 7, 2017 and Jun 4, 2020 — classified as 11 malfunctions.
The most frequently reported specific device problem is “Inflation Problem” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Inflation Problem3
- Material Split, Cut or Torn3
- Pressure Problem3
- Leak/Splash1
- Unintended Ejection1
Patient problems
- No Known Impact Or Consequence To Patient8
- Extubate3
Recent adverse event reports
The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 4, 2020Unintended Ejection
ET TUBE EXCHANGE REQUIRED SECONDARY TO CUFF LEAK.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10118354 ↗MalfunctionFeb 5, 2020Material Split, Cut or Torn; Material Split, Cut or Torn
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED SIX DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING DIFFERENT PATIENTS. THIS IS THE SIXTH OF SIX REPORTS. REFER TO 3011270181-2020-00018 FOR THE FIRST REPORT. REFER TO 3011270181-2020-00019 FOR THE SECOND REPORT. REFER TO 3011270181-2020-00020 FOR THE THIRD REPORT. REFER TO 3011270181-2020-00021 FOR THE FOURTH REPORT. REFER TO 3011270181-2020-00022 FOR THE FIFTH REPORT. IT WAS REPORTED THAT OVER THE PAST 21-30 DAYS THE USER FACILITY EXPERIENCED MULTIPLE INCIDENTS OF THE ETT [ENDOTRACHEAL TUBE] DEVELOPING TEARS IN THE CUFF. THE TEARS OCCURRED DURING USE WITH MULTIPLE DOCTORS WHO WERE ALL VERY FAMILIAR WITH USING THE PRODUCT. NO PATIENT INJURIES; HOWEVER, ALL INCIDENTS REQUIRED PATIENT TO BE REINTUBATED. ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER ON 28-JAN-2020 INDICATED "WE HAD A TOTAL OF 6 ETT CHANGES DUE TO CUFF FAILURE...IT WAS NOT THE SAME PATIENT EACH TIME. THE TEARS WERE NOTED IN THE CUFF ITSELF UPON REMOVAL OF THE ETT, BUT WAS NOT NOTED PRIOR TO INSPECTION."
Patient problems: Extubate
MAUDE report 9671265 ↗MalfunctionFeb 5, 2020Material Split, Cut or Torn; Material Split, Cut or Torn
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED SIX DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING DIFFERENT PATIENTS. THIS IS THE FOURTH OF SIX REPORTS. REFER TO 3011270181-2020-00018 FOR THE FIRST REPORT. REFER TO 3011270181-2020-00019 FOR THE SECOND REPORT. REFER TO 3011270181-2020-00020 FOR THE THIRD REPORT. REFER TO 3011270181-2020-00022 FOR THE FIFTH REPORT. REFER TO 3011270181-2020-00023 FOR THE SIXTH REPORT. IT WAS REPORTED THAT OVER THE PAST 21-30 DAYS THE USER FACILITY EXPERIENCED MULTIPLE INCIDENTS OF THE ETT [ENDOTRACHEAL TUBE] DEVELOPING TEARS IN THE CUFF. THE TEARS OCCURRED DURING USE WITH MULTIPLE DOCTORS WHO WERE ALL VERY FAMILIAR WITH USING THE PRODUCT. NO PATIENT INJURIES; HOWEVER, ALL INCIDENTS REQUIRED PATIENT TO BE REINTUBATED. ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER ON 28-JAN-2020 INDICATED "WE HAD A TOTAL OF 6 ETT CHANGES DUE TO CUFF FAILURE...IT WAS NOT THE SAME PATIENT EACH TIME. THE TEARS WERE NOTED IN THE CUFF ITSELF UPON REMOVAL OF THE ETT, BUT WAS NOT NOTED PRIOR TO INSPECTION."
Patient problems: Extubate
MAUDE report 9670397 ↗MalfunctionFeb 5, 2020Material Split, Cut or Torn; Material Split, Cut or Torn
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED SIX DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING DIFFERENT PATIENTS. THIS IS THE FIFTH OF SIX REPORTS. REFER TO 3011270181-2020-00018 FOR THE FIRST REPORT. REFER TO 3011270181-2020-00019 FOR THE SECOND REPORT. REFER TO 3011270181-2020-00020 FOR THE THIRD REPORT. REFER TO 3011270181-2020-00021 FOR THE FOURTH REPORT. REFER TO 3011270181-2020-00023 FOR THE SIXTH REPORT. IT WAS REPORTED THAT OVER THE PAST 21-30 DAYS THE USER FACILITY EXPERIENCED MULTIPLE INCIDENTS OF THE ETT [ENDOTRACHEAL TUBE] DEVELOPING TEARS IN THE CUFF. THE TEARS OCCURRED DURING USE WITH MULTIPLE DOCTORS WHO WERE ALL VERY FAMILIAR WITH USING THE PRODUCT. NO PATIENT INJURIES; HOWEVER, ALL INCIDENTS REQUIRED PATIENT TO BE REINTUBATED. ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER ON 28-JAN-2020 INDICATED "WE HAD A TOTAL OF 6 ETT CHANGES DUE TO CUFF FAILURE...IT WAS NOT THE SAME PATIENT EACH TIME. THE TEARS WERE NOTED IN THE CUFF ITSELF UPON REMOVAL OF THE ETT, BUT WAS NOT NOTED PRIOR TO INSPECTION."
Patient problems: Extubate
MAUDE report 9670396 ↗MalfunctionJun 12, 2019Pressure Problem; Pressure Problem
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED THREE DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING AN UNKNOWN NUMBER OF PATIENTS. THIS IS THE THIRD OF THREE REPORTS. REFER TO 3011270181-2019-00019 FOR THE FIRST REPORT. REFER TO 3011270181-2019-00020 FOR THE SECOND REPORT. IT WAS REPORTED THAT "WE WERE INFORMED OF A HALYARD MICROCUFF ENDOTRACHEAL TUBE'S CUFF THAT WOULDN'T HOLD AIR BECAUSE A LEAK WAS PRESENT.".
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8693908 ↗MalfunctionJun 12, 2019Pressure Problem; Pressure Problem
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED THREE DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING AN UNKNOWN NUMBER OF PATIENTS. THIS IS THE SECOND OF THREE REPORTS. REFER TO 3011270181-2019-00019 FOR THE FIRST REPORT, REFER TO 3011270181-2019-00021 FOR THE THIRD REPORT. IT WAS REPORTED THAT "WE WERE INFORMED OF A HALYARD MICROCUFF ENDOTRACHEAL TUBE'S CUFF THAT WOULDN'T HOLD AIR BECAUSE A LEAK WAS PRESENT."
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8693903 ↗MalfunctionJun 12, 2019Pressure Problem; Pressure Problem
AVANOS MEDICAL INC. RECEIVED A SINGLE REPORT THAT REFERENCED THREE DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING AN UNKNOWN NUMBER OF PATIENTS. THIS IS THE FIRST OF THREE REPORTS. REFER TO 3011270181-2019-00020 FOR THE SECOND REPORT. REFER TO 3011270181-2019-00021 FOR THE THIRD REPORT. IT WAS REPORTED THAT "WE WERE INFORMED OF A HALYARD MICROCUFF ENDOTRACHEAL TUBE'S CUFF THAT WOULDN'T HOLD AIR BECAUSE A LEAK WAS PRESENT."
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8693902 ↗MalfunctionAug 9, 2018Inflation Problem; Inflation Problem
HALYARD RECEIVED A SINGLE REPORT THAT REFERENCED AT LEAST THREE DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS. THIS IS THE THIRD OF THREE REPORTS. REFER TO 3011270181-2018-00030 FOR THE FIRST REPORT; REFER TO 3011270181-2018-00031 FOR THE SECOND REPORT. IT WAS REPORTED THAT THERE WAS DEFLATION OF THE OUTER BALLOON, AND CONDENSATION APPEARED TO BE PRESENT IN THE BALLOON, BUT THERE WAS NO OBSERVED LEAK.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7766891 ↗MalfunctionAug 9, 2018Inflation Problem; Inflation Problem
HALYARD RECEIVED A SINGLE REPORT THAT REFERENCED AT LEAST THREE DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS. THIS IS THE SECOND OF THREE REPORTS. REFER TO 3011270181-2018-00030 FOR THE FIRST REPORT; REFER TO 3011270181-2018-00032 FOR THE THIRD REPORT. IT WAS REPORTED THAT THERE WAS DEFLATION OF THE OUTER BALLOON, AND CONDENSATION APPEARED TO BE PRESENT IN THE BALLOON, BUT THERE WAS NO OBSERVED LEAK.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7766888 ↗MalfunctionAug 9, 2018Inflation Problem; Inflation Problem
HALYARD RECEIVED A SINGLE REPORT THAT REFERENCED AT LEAST THREE DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS. THIS IS THE FIRST OF THREE REPORTS. REFER TO 3011270181-2018-00031 FOR THE SECOND REPORT; REFER TO 3011270181-2018-00032 FOR THE THIRD REPORT. IT WAS REPORTED THAT THERE WAS DEFLATION OF THE OUTER BALLOON, AND CONDENSATION APPEARED TO BE PRESENT IN THE BALLOON, BUT THERE WAS NO OBSERVED LEAK.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7766887 ↗MalfunctionJul 7, 2017Leak/Splash; Leak/Splash
A MEDWATCH REPORT NUMBER (B)(4) WAS RECEIVED ON 19-JUN-2017. IT WAS REPORTED THAT, A FALL/TRAUMA PATIENT IN A C-COLLAR WAS INTUBATED WITH A GLIDESCOPE WITH SLIGHT DIFFICULTY. THE BALLOON WAS PRE-TESTED THE ENDOTRACHEAL TUBE PASSED WITHOUT COMPLICATION, AND THE PATIENT WAS INTUBATED. INITIALLY WITH THE APPROPRIATE PILOT BALLOON INFLATION WITH APPROXIMATELY 15CC OF AIR. THE RESPIRATORY THERAPIST NOTED THE PATIENT POSSIBLY HAD AIR LEAK (TIDAL VOLUME DOWN FROM 600S TO 400S; AUDIBLE). THE PILOT BALLOON WAS CHECKED AND WAS UNABLE TO MAINTAIN PRESSURE DESPITE REPEATED INFLATIONS WITH A SYRINGE. THE RESPIRATORY THERAPIST ATTACHED A 3-WAY STOPCOCK INSUFFLATION PORT AS A CAP AND THE PILOT BALLOON NOW INFLATED, IMPROVING VENTILATOR VOLUMES (500S). NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6692929 ↗
Other Tube, Tracheal (W/Wo Connector) devices
- Shiley 18875Covidien LP · Tube, tracheal (w/wo connector)4 deaths570 reports
- RUSCH IPN041476Teleflex Incorporated · Tube, tracheal (w/wo connector)10 recalls0 reports
- Shiley 18775Covidien LP · Tube, tracheal (w/wo connector)489 reports
- Shiley 18770Covidien LP · Tube, tracheal (w/wo connector)2 deaths434 reports
- Shiley 18880Covidien LP · Tube, tracheal (w/wo connector)2 deaths370 reports
- Shiley 18780Covidien LP · Tube, tracheal (w/wo connector)3 deaths286 reports
- Shiley 18770SCovidien LP · Tube, tracheal (w/wo connector)273 reports
- Shiley 18780SCovidien LP · Tube, tracheal (w/wo connector)251 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page