STRATAFIX SXPP2B403Recalls & reported problems

Ethicon, LLC · Stratafix (Spiral PDS Plus), Bidirectional · Class 2 · Implant

Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10705031464513), received between Dec 4, 2023 and Mar 18, 2026 — classified as 5 malfunctions.

The most frequently reported specific device problem is “Material Integrity Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 3 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Integrity Problem3
  • Positioning Failure3
  • Break1
  • Material Separation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 18, 2026Positioning Failure; Material Integrity Problem

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN PROCEDURE IN 2026 AND BARBED SUTURE WAS USED. DURING THE PROCEDURE, IT WAS REPORTED TO THE SALES REP THAT DURING AN UNKNOWN PROCEDURE THE STRATAFIX DEVICE, THE BARBS DID NOT APPEAR TO CUT DEEP ENOUGH AND WERE NOT ENGAGING THE TISSUE AS EXPECTED. THE HOSPITAL REPORTS THAT THEY USE STRATAFIX FREQUENTLY AND ARE FAMILIAR WITH ITS PERFORMANCE. WHILE SUTURING, THE BARBS WERE GRABBING INCONSISTENTLY. A SECOND DEVICE WAS OPENED, BUT STAFF NOTED THAT THE STRATAFIX ON THIS UNIT FELT DIFFERENT, AS IF THE BARBS WERE NOT FULLY FORMED OR WERE NOT ENGAGING PROPERLY. DEVICE IS RETURNING FOR RETURN. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24627961 ↗
  • MalfunctionMar 17, 2026Positioning Failure; Material Integrity Problem

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN PROCEDURE ON AN UNKNOWN DATE AND BARBED SUTURE WAS USED. DURING AN UNKNOWN PROCEDURE THE BARBED SUTURE DEVICE, THE BARBS DID NOT APPEAR TO CUT DEEP ENOUGH AND WERE NOT ENGAGING THE TISSUE AS EXPECTED. THE HOSPITAL REPORTS THAT THEY USE THE BARBED SUTURE FREQUENTLY AND ARE FAMILIAR WITH ITS PERFORMANCE. WHILE SUTURING, THE BARBS WERE GRABBING INCONSISTENTLY. A SECOND DEVICE WAS OPENED, BUT STAFF NOTED THAT THE BARBED SUTURE ON THIS UNIT FELT DIFFERENT, AS IF THE BARBS WERE NOT FULLY FORMED OR WERE NOT ENGAGING PROPERLY. DEVICE IS RETURNING FOR RETURN. THERE WERE NO PATIENT CONSEQUENCES REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24617717 ↗
  • MalfunctionMar 17, 2026Positioning Failure; Material Integrity Problem

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN PROCEDURE ON AN UNKNOWN DATE AND BARBED SUTURE WAS USED. DURING AN UNKNOWN PROCEDURE THE BARBED SUTURE DEVICE, THE BARBS DID NOT APPEAR TO CUT DEEP ENOUGH AND WERE NOT ENGAGING THE TISSUE AS EXPECTED. THE HOSPITAL REPORTS THAT THEY USE THE BARBED SUTURE FREQUENTLY AND ARE FAMILIAR WITH ITS PERFORMANCE. WHILE SUTURING, THE BARBS WERE GRABBING INCONSISTENTLY. A SECOND DEVICE WAS OPENED, BUT STAFF NOTED THAT THE BARBED SUTURE ON THIS UNIT FELT DIFFERENT, AS IF THE BARBS WERE NOT FULLY FORMED OR WERE NOT ENGAGING PROPERLY. DEVICE IS RETURNING FOR RETURN. THERE WERE NO PATIENT CONSEQUENCES REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24617712 ↗
  • MalfunctionNov 25, 2025Material Separation; Material Separation

    IT WAS REPORTED THAT A PATIENT UNDERWENT A C-SECTION PROCEDURE ON (B)(6) 2025 AND BARBED SUTURE WAS USED. DURING THE PROCEDURE, SUTURE SNAPPED OFF FROM SWAGE AFTER TWO BITES. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23647454 ↗
  • MalfunctionDec 4, 2023Break; Break

    IT WAS REPORTED THAT A PATIENT UNDERWENT A TOTAL KNEE REPLACEMENT PROCEDURE IN 2023 AND BARBED SUTURE WAS USED. DURING THE PROCEDURE, THE SALES REP REPORTED THAT WHEN THE SURGEON WAS USING, IT FELT LIKE THE BARB WASN'T SNATCHING THE TISSUE ENTIRELY DURING A TOTAL KNEE REPLACEMENT. SUTURE ENDED UP SNAPPING AS HE TRIED TO PULL BUT HE WENT TO USE A VICRYL TY TO COMPLETE CASE. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18263991 ↗

Other Suture, surgical, absorbable, polydioxanone devices

All Suture, surgical, absorbable, polydioxanone devices →