STRATAFIX SXPP2B419Recalls & reported problems

Ethicon, LLC · Stratafix (Spiral PDS Plus), Bidirectional · Class 2 · Implant

Adverse event reports
9
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 10705031464780), received between Sep 5, 2024 and Sep 23, 2026 — classified as 9 malfunctions.

The most frequently reported specific device problem is “Positioning Failure” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 5 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520265
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Positioning Failure7
  • Break6
  • Material Separation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions9

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 23, 2026Break

    It was reported that a patient underwent an Orthopedic procedure on (b)(6)2026 and barbed suture was used. During surgery, the suture was broken during use. It was not a control release needle. Another product was used to complete the case. No adverse patient consequences were reported. Additional information was requested

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50871280 ↗
  • MalfunctionJun 9, 2026Material Separation

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN PROCEDURE ON AN UNKNOWN DATE AND BARBED SUTURE WAS USED. DURING AN UNKNOWN SURGERY, THE SUTURE WAS DETACHED FROM THE NEEDLE EASILY WHEN THE PRODUCT WAS USED. THIS EVENT WAS FOUND BEFORE USE. IT WAS NOT A CONTROL RELEASE NEEDLE. ANOTHER PRODUCT WAS USED TO COMPLETE THE CASE. NO SAMPLE WILL BE RETURNED. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25447682 ↗
  • MalfunctionJan 13, 2026Break; Positioning Failure

    IT WAS REPORTED THAT A PATIENT UNDERWENT A PROCEDURE IN THE CATH LAB ON (B)(6) 2025 AND BARBED SUTURE WAS USED. DURING A PROCEDURE IN THE CATH LAB, THEY WERE USING A THE BARBED SUTURE AND MY CUSTOMER REPORTED THAT THE BARBS ON THESE SUTURES ASSOCIATED WITH THIS SPECIFIC LOT #'S WERE NOT PROMINENT AND AND NOT CATCHING/SITTING IN THE INCISION AS NEEDED. QUOTE FROM CUSTOMER" WHEN I TRIED TO PULL THE SUTURE TIGHT, IT WOULD SLIDE RIGHT OUT OR BREAK, IT WAS AS IF THIS LOT WAS MISSING BARBS. THERE WERE NO PATIENT CONSEQUENCES AND NO SIGNIFICANT DELAYS. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24052170 ↗
  • MalfunctionJan 13, 2026Break; Positioning Failure

    IT WAS REPORTED THAT A PATIENT UNDERWENT A PROCEDURE IN THE CATH LAB ON (B)(6) 2025 AND BARBED SUTURE WAS USED. DURING A PROCEDURE IN THE CATH LAB, THEY WERE USING A THE BARBED SUTURE AND MY CUSTOMER REPORTED THAT THE BARBS ON THESE SUTURES ASSOCIATED WITH THIS SPECIFIC LOT #'S WERE NOT PROMINENT AND NOT CATCHING/SITTING IN THE INCISION AS NEEDED. QUOTE FROM CUSTOMER" WHEN I TRIED TO PULL THE SUTURE TIGHT, IT WOULD SLIDE RIGHT OUT OR BREAK, IT WAS AS IF THIS LOT WAS MISSING BARBS. THERE WERE NO PATIENT CONSEQUENCES AND NO SIGNIFICANT DELAYS. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24052167 ↗
  • MalfunctionJan 13, 2026Break; Positioning Failure

    IT WAS REPORTED THAT A PATIENT UNDERWENT A PROCEDURE IN THE CATH LAB ON (B)(6) 2025 AND BARBED SUTURE WAS USED. DURING A PROCEDURE IN THE CATH LAB, THEY WERE USING A THE BARBED SUTURE AND MY CUSTOMER REPORTED THAT THE BARBS ON THESE SUTURES ASSOCIATED WITH THIS SPECIFIC LOT #'S WERE NOT PROMINENT AND NOT CATCHING/SITTING IN THE INCISION AS NEEDED. QUOTE FROM CUSTOMER" WHEN I TRIED TO PULL THE SUTURE TIGHT, IT WOULD SLIDE RIGHT OUT OR BREAK, IT WAS AS IF THIS LOT WAS MISSING BARBS. THERE WERE NO PATIENT CONSEQUENCES AND NO SIGNIFICANT DELAYS. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24052165 ↗
  • MalfunctionJan 13, 2026Break; Positioning Failure

    IT WAS REPORTED THAT A PATIENT UNDERWENT A PROCEDURE IN THE CATH LAB ON (B)(6) 2025 AND BARBED SUTURE WAS USED. DURING A PROCEDURE IN THE CATH LAB, THEY WERE USING A THE BARBED SUTURE AND MY CUSTOMER REPORTED THAT THE BARBS ON THESE SUTURES ASSOCIATED WITH THIS SPECIFIC LOT #'S WERE NOT PROMINENT AND AND NOT CATCHING/SITTING IN THE INCISION AS NEEDED. QUOTE FROM CUSTOMER" WHEN I TRIED TO PULL THE SUTURE TIGHT, IT WOULD SLIDE RIGHT OUT OR BREAK, IT WAS AS IF THIS LOT WAS MISSING BARBS. THERE WERE NO PATIENT CONSEQUENCES AND NO SIGNIFICANT DELAYS. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24052164 ↗
  • MalfunctionJan 13, 2026Break; Positioning Failure

    IT WAS REPORTED THAT A PATIENT UNDERWENT A PROCEDURE IN THE CATH LAB ON (B)(6) 2025 AND BARBED SUTURE WAS USED. DURING A PROCEDURE IN THE CATH LAB, THEY WERE USING A THE BARBED SUTURE AND MY CUSTOMER REPORTED THAT THE BARBS ON THESE SUTURES ASSOCIATED WITH THIS SPECIFIC LOT #'S WERE NOT PROMINENT AND NOT CATCHING/SITTING IN THE INCISION AS NEEDED. QUOTE FROM CUSTOMER" WHEN I TRIED TO PULL THE SUTURE TIGHT, IT WOULD SLIDE RIGHT OUT OR BREAK, IT WAS AS IF THIS LOT WAS MISSING BARBS. THERE WERE NO PATIENT CONSEQUENCES AND NO SIGNIFICANT DELAYS. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24052163 ↗
  • MalfunctionDec 12, 2024Positioning Failure; Positioning Failure

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN ORTHOPEDIC PROCEDURE ON (B)(6) 2024 AND BARBED SUTURE WAS USED. THE BARB HOOKING WAS BAD. IT WAS NOT A CONTROL RELEASE NEEDLE. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20919897 ↗
  • MalfunctionSep 5, 2024Positioning Failure; Positioning Failure

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN ORTHOPEDIC PROCEDURE ON AN UNKNOWN DATE AND BARBED SUTURE WAS USED. DURING THE PROCEDURE, IT WAS REPORTED BY A SALES REP THAT, IT COULD NOT BE USED BECAUSE IT WAS NOT HOOKED. ANOTHER PACKAGE COULD USE WITHOUT PROBLEM. IT WAS NOT A CONTROL RELEASE NEEDLE. FURTHER DETAILS ARE NOT PROVIDED FROM THE HP. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20146531 ↗

Other Suture, surgical, absorbable, polydioxanone devices

All Suture, surgical, absorbable, polydioxanone devices →