AVANTI 402607XRecalls & reported problems
Cordis Corporation · SI AVANTI+ .035 F7 W/MINI GW · Class 2
All models of AVANTI (19)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10705032000673), received between Nov 14, 2024 and Dec 9, 2024 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (2 reports).
2 other recalls cover devices cleared under the same FDA submission (K970392); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 9, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
AS REPORTED, DURING THE CORONARY ABLATION PROCEDURE, THE 7F .035-INCH AVANTI+ SHEATH INTRODUCER BROKE WHILE BEING WITHDRAWN. WHEN THE SHEATH BROKE ONLY PART OF THE SHEATH WAS WITHDRAWN. THE OPERATOR REPORTED THAT HE DID NOT FEEL ANY ABNORMAL RESISTANCE DURING THE WITHDRAWAL OF THE SHEATH AND DID NOT USE A LOT OF FORCE WHEN WITHDRAWING THE SHEATH. THE SURGEON PRESSED ON THE DISTAL PORTION OF THE VESSEL AS SOON AS HE REALIZED THAT THE SHEATH HAD BROKEN AND REMOVED THE ENTIRE BROKEN SHEATH WITH FORCEPS; HENCE, THE SHEATH FRACTURE SITE APPEARS AS A FLATTENED LACERATION. INITIALLY, A SHORT 7F AVANTI+ SHEATH WAS PLACED THROUGH FEMORAL VEIN PUNCTURE, AND THE GUIDEWIRE AND 7F CORONARY SINUS ELECTRODE WERE DELIVERED AFTER SUCCESSFUL PUNCTURE. THE SHEATH INSERTION WAS SMOOTH DURING THE PUNCTURE AND DELIVERY OF THE INSTRUMENTS, WITH NO SIGNIFICANT RESISTANCE. LATER, DUE TO THE NEEDS OF THE PROCEDURE, THE SHEATH WAS INTENDED TO BE REPLACED WITH A LARGER ONE. THEREFORE, ALL INSTRUMENTS WERE WITHDRAWN, AND AN EXCHANGE GUIDEWIRE WAS PLACED WITH THE INTENTION OF WITHDRAWING THE 7F SHEATH. THAT IS WHEN THE SHEATH BROKE. A CONTRALATERAL APPROACH WAS USED. THE ACCESS SITE VESSEL CHARACTERISTICS WERE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20887580 ↗InjuryNov 14, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
AS REPORTED, UPON REMOVAL FROM THE PATIENT, THE 7F 11 CM AVANTI PLUS SHEATH INTRODUCER WITH MINI-GUIDEWIRE WAS NOTED BROKEN. ONE PART OF THE CATHETER STAYED IN THE PATIENT'S RIGHT HAND AND THE TIP STAYED IN THE PATIENT. THE PHYSICIAN WAS SUCCESSFUL IN REMOVING THE DISTAL PART FROM THE PATIENT. THE 7F SHEATH WAS BEING USED FOR AN ATRIAL FIBRILLATION ABLATION PROCEDURE FOR A QUADRIPOLAR NON-CORDIS LEAD FOR FEMORAL VENOUS ACCESS. A PICTURE WAS RECEIVED FOR REVIEW. THE DEVICE IS EXPECTED TO BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20684657 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K970392. One submission often covers many models, so check the product and lot details in each record.
- Z-2079-2021 · Jun 9, 2021 · TerminatedAvanti+ Catheter Sheath Introducer - Product Usage: Is indicated for use in arterial and venous procedures requiring percutaneous introduction of intravascular devices.
- Z-1174-2016 · Dec 31, 2015 · TerminatedCORDIS AVANTI + CATHETER SHEATH INTRODUCER SYSTEM The product includes a Catheter Sheath Introducer (CSI) and a vessel dilator. A Catheter Sheath Introducer facilitates percutaneo
Other DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION devices
- VersaCross Connect LAAC Access Solution VXAK0007Baylis Médicale Cie Inc · Dilator, Vessel, For Percutaneous Catheterization3 deaths108 reports
- TandemLife 5740-2417Cardiacassist, Inc. · Dilator, Vessel, For Percutaneous Catheterization2 recalls0 reports
- TightRail Rotating Dilator Sheath 545-513Spectranetics Corporation · Dilator, Vessel, For Percutaneous Catheterization20 deaths74 reports
- VersaCross Connect LAAC Access Solution VXAK0003Baylis Médicale Cie Inc · Dilator, Vessel, For Percutaneous Catheterization2 deaths70 reports
- VersaCross Connect LAAC Access Solution VXAK0007Baylis Médicale Cie Inc · Dilator, Vessel, For Percutaneous Catheterization2 deaths54 reports
- AVANTI 504656XCordis Corporation · DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION1 recall2 reports
- Abiomed® 00884450732311Merit Medical Systems, Inc. · Dilator, Vessel, For Percutaneous Catheterization1 recall1 report
- Mini Stick MAX H965457510Angiodynamics, Inc. · DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page