TEMPO 451431H0Recalls & reported problems
Cordis Corporation · CATH TEMPO 4F SIM 2 100CM · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10705032007948), received between Jul 28, 2020 and Jan 30, 2026 — classified as 1 injury, 3 malfunctions.
The most frequently reported specific device problem is “Leak/Splash” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Leak/Splash2
- Crack1
- Detachment of Device or Device Component1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- Foreign Body In Patient1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 30, 2026Leak/Splash
AS REPORTED, THE HUB OF A 4F SIM 2 100CM TEMPO DIAGNOSTIC CATHETER WAS LEAKING. THERE WAS NO REPORTED PATIENT INJURY. THE INTENDED PROCEDURE WAS A MIDDLE MENINGEAL ARTERY (MMA) EMBOLIZATION. THE LEAK WAS IDENTIFIED AT THE HUB WHERE THE CATHETER CONNECTS TO THE LUER END AND WAS NOTICED WHEN ATTEMPTING TO PERFORM A HAND INJECTION. A CONTRALATERAL APPROACH WAS NOT USED. THE ACCESS SITE VESSEL WAS DESCRIBED AS NORMAL. THE DEVICE WAS FLUSHED PRIOR TO USE, AND THE SHEATH DILATOR WAS SECURELY CONNECTED AT THE HUB. NO DIFFICULTIES WERE ENCOUNTERED DURING INSERTION OR WITHDRAWAL. THE PRODUCT WAS STORED AND HANDLED ACCORDING TO THE INSTRUCTIONS FOR USE. NO DEVICE DAMAGE WAS NOTED PRIOR TO OPENING THE PACKAGE. THERE WAS NO DIFFICULTY REMOVING THE DEVICE FROM THE STERILE PACKAGING. NO UNUSUAL FORCE WAS USED DURING THE PROCEDURE, AND NO DIFFICULTIES WERE ENCOUNTERED WHILE INSERTING OR WITHDRAWING ANY CONCOMITANT DEVICES. THE DEVICE WILL BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24223292 ↗MalfunctionNov 27, 2024Leak/Splash; Leak/Splash
AS REPORTED, WHEN USING A 4F 100CM SIDEWINDER SIMMONS 2 (SIM2) TEMPO DIAGNOSTIC CATHETER TO PERFORM AN ANGIOGRAM IN THE SUPERFICIAL FEMORAL ARTERY (SFA), THE DEVICE WAS CONNECTED TO AN UNKNOWN Y-VALVE AND LIQUID LEAKAGE WAS FOUND AT THE CONNECTION. THIS ¿TRIGGERED EXTRAVASATION OF THE CONTRAST AGENT WHEN IT WAS INJECTED INTO THE CONTRAST MEDIUM¿ WITH A HIGH-PRESSURE CONTRAST INJECTOR, WHICH AFFECTED THE QUALITY OF THE IMAGE. ADDITIONALLY, LARGE AMOUNTS OF LIQUID SEEPAGE WERE OBSERVED, AFFECTING THE ASEPTIC ENVIRONMENT. EXTRAVASATION, DEFINED AS A LEAKAGE OF A SOLUTION OUT OF THE VESSEL AND INTO THE SURROUNDING TISSUE OF THE PATIENT, DID NOT OCCUR. HOWEVER, THE TERM ¿EXTRAVASATION¿ WAS USED TO DESCRIBE AN EXCESS LEAKAGE OF CONTRAST SOLUTION COMING FROM THE LUER HUB CONNECTION, OUTSIDE OF THE PATIENT. THE PROCEDURE WAS COMPLETED BY CHANGING TO A NEW UNKNOWN CATHETER. THERE WERE NO REPORTED INJURIES TO THE PATIENT AND THE PATIENT WAS IN GOOD STATUS POST-PROCEDURE. THE DEVICE WAS STORED AND PREPPED PER THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO DAMAGE TO THE LUER HUB OF THE 4F SIM2 TEMPO CATHETER, AND THERE WAS NO DIFFICULTY CONNECTING THE Y-VALVE TO THE LUER HUB OF THE 4F SIM2 TEMPO
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20795557 ↗MalfunctionApr 8, 2024Crack; Crack
AS REPORTED, A 4F 100CM TEMPO CATHETER SIDEWINDER II (SIM 2) CATHETER WAS OBSERVED FRACTURED. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICE IS EXPECTED TO BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19059548 ↗InjuryJul 28, 2020Detachment of Device or Device Component; Detachment of Device or Device Component
AS REPORTED, THE 4F 100CM TEMPO CATHETER WENT OFF AND HAD TO BE REMOVED WITH THE HELP OF A VASCULAR SURGEON. THE MALFUNCTION OCCURRED DURING A NORMAL ANGIO PROCEDURE. THE DEVICE WAS STORED PER LABELLING AND OPENED IN STERILE FIELD. THE DEVICE WAS STORED AND HANDLED PER THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO DAMAGE NOTED TO THE PACKAGE. THE INTEGRITY OF THE STERILE POUCH WAS NOT COMPROMISED. THE DEVICE WILL BE RETURNED FOR ANALYSIS.
Patient problems: Foreign Body In Patient
MAUDE report 10332895 ↗
Other CATHETER, INTRAVASCULAR, DIAGNOSTIC devices
- TrapEase Permanent Vena Cava Filter with the VisEase Angiographic Vessel Dilator 466P306AUCordis Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC6 deaths186 reports
- Dragonfly™ OPTIS™ C408646Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC4 deaths150 reports
- Dragonfly OpStar™ 1014651Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC1 recall87 reports
- LANGSTON IPN913559Teleflex Incorporated · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls14 reports
- Trevo 90238Stryker Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls5 reports
- Expo™ H749085263011Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls3 reports
- Expo™ H74908526501Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls1 report
- Expo™ H74908526031Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page