SUPERTORQUE 533621Recalls & reported problems

Cordis Corporation · CATH F6 ST+ JR 4 100CM · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10705032013048), received between May 7, 2024 and Mar 31, 2025 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1
  • Device-Device Incompatibility1
  • Difficult to Remove1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 31, 2025Device-Device Incompatibility; Device-Device Incompatibility

    AS REPORTED, DURING A CORONARY ANGIOGRAM, THE F6 ST+ JR 4 SUPERTORQUE DIAGNOSTIC CATHETER WAS FOUND TO NOT LOCK INTO MANIFOLD EXTENSION TUBING RESULTING IN INADEQUATE AND UNSAFE CONNECTION FOR INTRAARTERIAL/INTRACORONARY CONTRAST INJECTIONS. THE DAMAGE WAS NOTICED UPON CONNECTION PRIOR TO USE. THE CORDIS JR 4 100CM SUPER TORQUE PLUS WAS REMOVED FROM PROCEDURE, A NEW CORDIS JR 4 100CM SUPER TORQUE PLUS WAS PROVIDED, IT WAS FOUND TO CONNECT ADEQUATELY IN ORDER ALLOW CORONARY ANGIOGRAM TO PROCEED. THERE WAS NO REPORTED INJURY TO THE PATIENT. THERE WAS NO DAMAGE TO THE PACKAGING OF THE DEVICE. THE PRODUCT WAS STORED IN THE LAB BY HANGING ON A HOOK WITH THE PROVIDED HANGING POINT. NO ANOMALIES WERE NOTED WHEN THE DEVICE WAS TAKEN OUT OF THE PACKAGE. THE DEVICE WAS NOT PULLED FROM THE PACKAGING BY THE HUB, AND NO ANOMALIES WERE NOTED AT THIS TIME. THE DEVICE WAS PREPPED PER THE IFU. NO DIFFICULTY WAS EXPERIENCED IN PREPPING THE DEVICE. THE CATHETER WAS NOT ADVANCED THROUGH THE SHEATH, SO THERE WAS NO RESISTANCE OR FRICTION. NO EXCESS FORCE WAS USED DURING THE CASE. THE DEVICE WAS DISCARDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21729777 ↗
  • InjuryMay 7, 2024Difficult to Remove; Detachment of Device or Device Component; Difficult to Remove; Detachment of Device or Device Component

    AS REPORTED, A CORONARY ANGIOGRAPHY WAS PERFORMED ON A PATIENT VIA THE RADIAL ARTERY. UPON COMPLETION OF THE PROCEDURE, THE 6F JR4 SUPER TORQUE + CATHETER COULD NOT BE WITHDRAWN DUE TO COMPLICATIONS AT THE LEVEL OF THE RADIAL ARTERY (SPASM), DESPITE VARIOUS ATTEMPTS (PHARMACOLOGICAL, ANESTHETIC, ETC). VASOSPASM WAS CAUSED DUE TO THE PRESENCE OF THE CATHETER. THE CATHETER WAS REMOVED THROUGH A VASCULAR SURGEON. THE CATHETER WAS REMOVED DURING SURGERY (CUT DOWN). IT WAS NOTED THAT THE CATHETER DID NOT BREAK INTO TWO PIECES. THE CATHETER WAS CUT BY THE VASCULAR SURGEON AT 2 POINTS. 1. AT THE PUNCTURE SITE OF THE RADIAL ARTERY, 2. AT THE LEVEL OF THE BIFURCATION OF THE BRACHIAL ARTERY AFTER SURGICAL EXPOSURE) SO THAT IT COULD BE REMOVED FROM THE RADIAL ARTERY BY TRACTION, WHICH WAS ULTIMATELY ACHIEVED. THE DEVICE WAS PREPARED AS SPECIFIED BY THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO APPARENT DAMAGE TO THE DEVICE NOTICED PRIOR TO USE. THERE WAS NO RESISTANCE/FRICTION WHILE ADVANCING THROUGH THE VESSEL. UNUSUAL FORCE WAS NOT NEEDED TO ADVANCE OR WITHDRAWAL THE CATHETER FROM THE PATIENT. THE INTENDED PROCEDURE WAS A CORONARY ANGIOGRAPHY. THE VESSEL DID NOT HAVE ANY TORTUOSITY. A GUIDEW

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19259526 ↗