INFINITI 534676TRecalls & reported problems
Cordis US Corp. · CATH F6INF TL 3DRC 100CM · Class 2
All models of INFINITI (20)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10705032014489), received between May 4, 2018 and Oct 20, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Crack” (2 reports).
3 other recalls cover devices cleared under the same FDA submission (K970854); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Crack2
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 20, 2025Crack; Crack
AS REPORTED, THE TIP OF A 6F 100 CM 3DRC INFINITI DIAGNOSTIC CATHETER FRACTURED WHILE A .035-INCH WIRE WAS BEING INTRODUCED THROUGH THE CATHETER. THE CATHETER DID NOT BECOME ENTRAPPED, AND THERE WAS NO DEVICE SEPARATION. A SECOND 3DRC INFINITI CATHETER WAS USED TO COMPLETE THE ANGIOGRAPHY PROCEDURE, AND A CONTRALATERAL APPROACH WAS NOT USED. THERE WAS NO REPORTED PATIENT INJURY. THERE WAS NO DAMAGE IN THE CATHETER PACKAGING. THE PRODUCT WAS STORED ON THE SHELF IN THE CATH. LAB AND OPENED IN STERILE FIELD. THE DEVICE WAS PREPPED PER THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO KINK IN THE DISTAL OF THE CATHETER WAS REMARKED. THE DEVICE DAMAGE WAS NOT NOTICED ONCE THE CATHETER WAS OPENED FROM THE PACKAGING. NO FORCE WAS APPLIED BECAUSE THE CATHETER DID NOT INTRODUCE THROUGH THE SHEATH. AT THE TARGET SITE, THE VESSEL WAS NON-CALCIFIED, MILDLY TORTUOUS, NON-BIFURCATING, AND THE STENOSIS PERCENTAGE AND PRESENCE OF AN ACUTE ANGLE WERE NOT AVAILABLE. AT THE ACCESS SITE, THE VESSEL WAS NEITHER CALCIFIED NOR TORTUOUS, AND DETAILS ON STENOSIS PERCENTAGE, ACUTE ANGLE, AND BIFURCATION WERE NOT AVAILABLE. THE DEVICE WAS NEITHER PULLED FROM THE PACKAGING BY THE HUB NOR TORQUED/STEERED BY THE HUB
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23335438 ↗MalfunctionMay 4, 2018Crack; Crack
BEFORE USE, THE TIP OF THE 6F INFINITI CATHETER WAS NOT ATTACHED AND WAS HANGING BY A PIECE OF PLASTIC. THERE WAS NO PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7487688 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K970854. One submission often covers many models, so check the product and lot details in each record.
- Z-0286-2024 · Sep 26, 2023 · Open, ClassifiedCordis ANGIOGRAPHIC CATHETERIZATION SETS, INFINITI THRULEMEN, 5F, REF CO0208, cardiac catheter
- Z-0720-2023 · Nov 7, 2022 · Open, ClassifiedCordis Angiographic Catheter Extensions. Used to transport fluid from the power injector to the catheter for injection into the patient.
- Z-1240-06 · Jun 26, 2006 · TerminatedCordis INFINITI 6 French Diagnostic Catheter. Catalog 534-6xxT. That is: 534614T, 534615T, 534617T, 534618T, 534619T, 534620T, 534621T, 534622T, 534623T, 534624T, 534625T, 534627T
Other CATHETER, INTRAVASCULAR, DIAGNOSTIC devices
- TrapEase Permanent Vena Cava Filter with the VisEase Angiographic Vessel Dilator 466P306AUCordis Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC6 deaths186 reports
- Dragonfly™ OPTIS™ C408646Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC4 deaths150 reports
- Dragonfly OpStar™ 1014651Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC1 recall87 reports
- LANGSTON IPN913559Teleflex Incorporated · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls14 reports
- Trevo 90238Stryker Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls5 reports
- Expo™ H749085263011Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls3 reports
- Expo™ H74908526501Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls1 report
- Expo™ H74908526031Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page