INFINITI 538453SRecalls & reported problems
Cordis Corporation · CATH4F INF PIG 145° MOD 110CM · Class 2
All models of INFINITI (22)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10705032014847), received between Feb 9, 2024 and Nov 11, 2024 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Material Puncture/Hole” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Material Puncture/Hole3
- Detachment of Device or Device Component1
- Difficult to Remove1
- Material Frayed1
- Material Split, Cut or Torn1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 11, 2024Material Frayed; Material Puncture/Hole; Material Split, Cut or Torn; Material Frayed; Material Puncture/Hole; Material Split, Cut or Torn
AS REPORTED, THE 4F 110CM PIG INFINITI GUIDING CATHETER TORE DURING THE ROUTINE EXAMINATION WHEN TRYING TO BRING IT FORWARD. THE WIRE CAME OUT OF THE SIDE OF THE CATHETER (NOT THROUGH SHS OR ORIGINAL LUMEN). THE EXAMINER THEN WITHDREW THE DIAGNOSTIC (DX) CATHETER, AND THE TIP BROKE OFF. THE DISTAL PORTION OF THE CATHETER WAS NOTED TO HAVE SEPARATED, ABOUT 5CMS. THE DEVICE WAS NOTED TO HAVE PUNCTURED AND SEPARATED AT THE SAME LOCATION ON THE CATHETER. IT WAS THEN RETRIEVED FROM THE GROIN WITH THE SNARE. THE PROCEDURE WAS COMPLETED WITH A NEW PIGTAIL CATHETER FROM CORDIS. THE DEVICE WAS REMOVED WITHOUT PATIENT INJURY. THE DEVICE WAS PREPARED PER THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO APPARENT DAMAGE NOTED ON THE DEVICE PRIOR TO USE. THERE WAS NO RESISTANCE/ FRICTION WHILE ADVANCING THE DEVICE THROUGH THE VESSEL. UNUSUAL FORCE WAS NOT NEEDED TO ADVANCE OR WITHDRAW THE CATHETER FROM THE PATIENT. THE UNKNOWN LESION WAS NOTED TO HAVE NO CALCIFICATION. THE VESSEL WAS NOT TORTUROUS. A NON-CORDIS .035 150CM WIRE WAS USED WITH THE DEVICE. THE DEVICE WILL BE RETURNED FOR EVALUATION. AN ADDITIONAL, STERILE INFINITI PIGTAIL CATHETER WAS RETURNED FOR EVALUATION. THE EVALUATION SHOWS PUNCTU
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20652718 ↗MalfunctionSep 6, 2024Material Puncture/Hole; Detachment of Device or Device Component; Material Puncture/Hole; Detachment of Device or Device Component
AS REPORTED, THE 4F 110CM PIG INFINITI GUIDING CATHETER TORE DURING THE ROUTINE EXAMINATION WHEN TRYING TO BRING IT FORWARD. THE WIRE CAME OUT OF THE SIDE OF THE CATHETER (NOT THROUGH SHS OR ORIGINAL LUMEN). THE EXAMINER THEN WITHDREW THE DIAGNOSTIC (DX) CATHETER, AND THE TIP BROKE OFF. THE DISTAL PORTION OF THE CATHETER WAS NOTED TO HAVE SEPARATED, ABOUT 5CMS. THE DEVICE WAS NOTED TO HAVE PUNCTURED AND SEPARATED AT THE SAME LOCATION ON THE CATHETER. IT WAS THEN RETRIEVED FROM THE GROIN WITH THE SNARE. THE PROCEDURE WAS COMPLETED WITH A NEW PIGTAIL CATHETER FROM CORDIS. THE DEVICE WAS REMOVED WITHOUT PATIENT INJURY. THE DEVICE WAS PREPARED PER THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO APPARENT DAMAGE NOTED ON THE DEVICE PRIOR TO USE. THERE WAS NO RESISTANCE/ FRICTION WHILE ADVANCING THE DEVICE THROUGH THE VESSEL. UNUSUAL FORCE WAS NOT NEEDED TO ADVANCE OR WITHDRAW THE CATHETER FROM THE PATIENT. THE UNKNOWN LESION WAS NOTED TO HAVE NO CALCIFICATION. THE VESSEL WAS NOT TORTUROUS. A NON-CORDIS .035 150CM WIRE WAS USED WITH THE DEVICE. THE DEVICE WILL BE RETURNED FOR EVALUATION. AN ADDITIONAL, STERILE INFINITI PIGTAIL CATHETER WAS RETURNED FOR EVALUATION. THE EVALUATION SHOWS PUNCTU
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20158379 ↗MalfunctionFeb 9, 2024Material Puncture/Hole; Difficult to Remove; Material Puncture/Hole; Difficult to Remove
AS REPORTED, A 4F 110CM, PIGTAIL 145 DEGREES, 6-SIDEHOLE (SH) MICRO LOOP INFINITI DIAGNOSTIC CATHETER GOT STUCK IN THE RADIAL ARTERY. IT BECAME "UNSTUCK" AND "DOUBLED OVER ITSELF AND BROKE". THE CATHETER DID NOT BREAK APART, HOWEVER, THE CATHETER KINKED ON ITSELF AND THE .035IN WIRE PUNCTURED OUT AT THE KINK. THERE WERE NO REPORTS OF PATIENT INJURY. THE DEVICE WAS KEPT IN THE CATH LAB. THE ACCESS SITE AND TARGET SITE VESSEL WERE OF NORMAL ANATOMY. THE DEVICE WAS REMOVED PROPERLY. THE DEVICE WAS TORQUED OR ¿STEERED¿ BY THE HUB. WHEN WITHDRAWING THE DEVICE, THE CATHETER HAD KINKED, AND WHEN THE .035 WIRE WAS ADVANCED IN, IT EXITED AT THE KINK (NOT THE LUMEN). THE CATHETER DID NOT BREAK APART. THE CATHETER BENT OVER ON ITSELF IN THE RIGHT BRACHIAL-CEPHALIC ARTERY. THE DEVICE WAS PROPERLY STORED. THE PATIENT HAD NO ISSUES AND RECEIVED AN INTERVENTION VIA THE SAME RIGHT RADIAL APPROACH. THE CATHETER WILL BE RETURNED FOR EVALUATION. PER IMAGE REVIEW, THE RADIOGRAPHIC IMAGE APPEARS TO DISPLAY A PIGTAIL CATHETER IN THE RIGHT RADIAL ARTERY. THREE KINKED CONDITIONS ARE NOTED TOWARD THE DISTAL END OF THE CATHETER. THE MOST PROXIMAL KINK HAS CAUSED THE DISTAL END OF CATHETER TO FOLD OVER AND P
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18677973 ↗
Other CATHETER, INTRAVASCULAR, DIAGNOSTIC devices
- TrapEase Permanent Vena Cava Filter with the VisEase Angiographic Vessel Dilator 466P306AUCordis Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC6 deaths186 reports
- Dragonfly™ OPTIS™ C408646Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC4 deaths150 reports
- Dragonfly OpStar™ 1014651Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC1 recall87 reports
- LANGSTON IPN913559Teleflex Incorporated · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls14 reports
- Trevo 90238Stryker Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls5 reports
- Expo™ H749085263011Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls3 reports
- Expo™ H74908526501Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls1 report
- Expo™ H74908526031Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page