TEMPO SRD5559Recalls & reported problems

Cordis Corporation · 5F TEMPO 0.038 125CM II · Class 2

Adverse event reports
9
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 10705032048545), received between Mar 15, 2021 and Mar 6, 2026 — classified as 1 injury, 8 malfunctions.

The most frequently reported specific device problem is “Peeled/Delaminated” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 4 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 3 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Peeled/Delaminated4
  • Degraded3
  • Material Puncture/Hole3
  • Detachment of Device or Device Component2

Patient problems

  • No Clinical Signs, Symptoms or Conditions9

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 6, 2026Detachment of Device or Device Component

    AS REPORTED, A 5F 125 CM TEMPO DIAGNOSTIC CATHETER BROKE OFF AT THE HUB DURING EXTRACTION FROM THE SHEATH. THE SEPARATED SEGMENT WAS BROKEN OFF IN THE PATIENT¿S BODY BUT WAS SUCCESSFULLY RETRIEVED. THERE WERE NO REPORTED INJURIES TO THE PATIENT. ADDITIONAL INFORMATION WAS REQUESTED BUT WAS NOT PROVIDED. THE DEVICE WAS NOT RETURNED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24532053 ↗
  • MalfunctionJun 24, 2024Degraded; Material Puncture/Hole; Degraded; Material Puncture/Hole

    AS REPORTED, FOUR 5F SIDEWINDER II TEMPO 0.038 125CM DIAGNOSTIC CATHETERS WERE FOUND TO BE CUT AT ANGULATION WITH RISK OF DETACHMENT IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER 5F TEMPO 0.038 125CM DIAGNOSTIC CATHETER OF A DIFFERENT LOT NUMBER. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICES WERE MEANT TO BE USED IN THROMBECTOMY PROCEDURES. OTHER PROCEDURAL DETAILS WERE REQUESTED BUT ARE UNKNOWN, UNAVAILABLE, NOT ANSWERED, OR NOT APPLICABLE. THE FOUR DEVICES USED WILL BE RETURNED FOR EVALUATION AS WELL AS ONE STERILE DEVICE AND ONE DEVICE THAT WAS OPENED BY MISTAKE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19594120 ↗
  • MalfunctionJun 24, 2024Degraded; Material Puncture/Hole; Degraded; Material Puncture/Hole

    AS REPORTED, FOUR 5F SIDEWINDER II TEMPO 0.038 125CM DIAGNOSTIC CATHETERS WERE FOUND TO BE CUT AT ANGULATION WITH RISK OF DETACHMENT IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER 5F TEMPO 0.038 125CM DIAGNOSTIC CATHETER OF A DIFFERENT LOT NUMBER. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICES WERE MEANT TO BE USED IN THROMBECTOMY PROCEDURES. OTHER PROCEDURAL DETAILS WERE REQUESTED BUT ARE UNKNOWN, UNAVAILABLE, NOT ANSWERED, OR NOT APPLICABLE. THE FOUR DEVICES USED WILL BE RETURNED FOR EVALUATION AS WELL AS ONE STERILE DEVICE AND ONE DEVICE THAT WAS OPENED BY MISTAKE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19594095 ↗
  • MalfunctionJun 24, 2024Degraded; Material Puncture/Hole; Degraded; Material Puncture/Hole

    AS REPORTED, FOUR 5F SIDEWINDER II TEMPO 0.038 125CM DIAGNOSTIC CATHETERS WERE FOUND TO BE CUT AT ANGULATION WITH RISK OF DETACHMENT IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER 5F TEMPO 0.038 125CM DIAGNOSTIC CATHETER OF A DIFFERENT LOT NUMBER. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICES WERE MEANT TO BE USED IN THROMBECTOMY PROCEDURES. OTHER PROCEDURAL DETAILS WERE REQUESTED BUT ARE UNKNOWN, UNAVAILABLE, NOT ANSWERED, OR NOT APPLICABLE. THE FOUR DEVICES USED WILL BE RETURNED FOR EVALUATION AS WELL AS ONE STERILE DEVICE AND ONE DEVICE THAT WAS OPENED BY MISTAKE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19594076 ↗
  • MalfunctionJan 17, 2024Peeled/Delaminated; Peeled/Delaminated

    AS REPORTED, WHEN OPENING FOUR (4) 5F TEMPO 0.038 125CM GUIDING CATHETERS WERE FOUND BROKEN DISTALLY (CURVATURE) AND PROXIMALLY. THE DEVICES COULD NOT BE USED. THERE WAS NO REPORTED PATIENT INJURY. THE DAMAGE WAS NOTICED DURING THE PROCEDURE. THE SHAPE OF THE BODY/SHAFT WAS DESCRIBED AS "LIKE TURTLE OR FISH SCALES AT THE SHAPE"(TINY PIECES CRACKED BUT STILL ATTACHED TO ONE POINT ON THE CATHETER). THE BRAIDED CORE WIRE WAS NOT EXPOSED AND IT IS UNKNOWN IF THE CATHETERS WERE DELAMINATED OR COMPRESSED CRUSHED AS IT WAS FURTHER CLARIFIED. THE PRODUCTS WERE STORED, HANDLED, AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU) AND THERE WAS NO DEVICE DAMAGE NOTICED PRIOR TO OPENING THE PACKAGES OR DIFFICULTY REMOVING THE DEVICES FROM THE STERILE PACKAGING. THERE WAS NO DIFFICULTY EXPERIENCED IN PREPPING THE DEVICES. THE PROCEDURE WAS COMPLETED USING AN UNKNOWN CORDIS DEVICE WITH A DIFFERENT SHAPE. ALL 4 DEVICES WERE DISCARDED AT SITE AFTER THE PROCEDURE AND WILL NOT BE RETURNED FOR EVALUATION. PICTURES ARE NOT AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18531157 ↗
  • MalfunctionJan 17, 2024Peeled/Delaminated; Peeled/Delaminated

    AS REPORTED, WHEN OPENING FOUR (4) 5F TEMPO 0.038 125CM GUIDING CATHETERS WERE FOUND BROKEN DISTALLY (CURVATURE) AND PROXIMALLY. THE DEVICES COULD NOT BE USED. THERE WAS NO REPORTED PATIENT INJURY. THE DAMAGE WAS NOTICED DURING THE PROCEDURE. THE SHAPE OF THE BODY/SHAFT WAS DESCRIBED AS "LIKE TURTLE OR FISH SCALES AT THE SHAPE"(TINY PIECES CRACKED BUT STILL ATTACHED TO ONE POINT ON THE CATHETER). THE BRAIDED CORE WIRE WAS NOT EXPOSED AND IT IS UNKNOWN IF THE CATHETERS WERE DELAMINATED OR COMPRESSED CRUSHED AS IT WAS FURTHER CLARIFIED. THE PRODUCTS WERE STORED, HANDLED, AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU) AND THERE WAS NO DEVICE DAMAGE NOTICED PRIOR TO OPENING THE PACKAGES OR DIFFICULTY REMOVING THE DEVICES FROM THE STERILE PACKAGING. THERE WAS NO DIFFICULTY EXPERIENCED IN PREPPING THE DEVICES. THE PROCEDURE WAS COMPLETED USING AN UNKNOWN CORDIS DEVICE WITH A DIFFERENT SHAPE. ALL 4 DEVICES WERE DISCARDED AT SITE AFTER THE PROCEDURE AND WILL NOT BE RETURNED FOR EVALUATION. PICTURES ARE NOT AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18529518 ↗
  • MalfunctionJan 17, 2024Peeled/Delaminated; Peeled/Delaminated

    AS REPORTED, WHEN OPENING FOUR (4) 5F TEMPO 0.038 125CM GUIDING CATHETERS WERE FOUND BROKEN DISTALLY (CURVATURE) AND PROXIMALLY. THE DEVICES COULD NOT BE USED. THERE WAS NO REPORTED PATIENT INJURY. THE DAMAGE WAS NOTICED DURING THE PROCEDURE. THE SHAPE OF THE BODY/SHAFT WAS DESCRIBED AS "LIKE TURTLE OR FISH SCALES AT THE SHAPE"(TINY PIECES CRACKED BUT STILL ATTACHED TO ONE POINT ON THE CATHETER). THE BRAIDED CORE WIRE WAS NOT EXPOSED AND IT IS UNKNOWN IF THE CATHETERS WERE DELAMINATED OR COMPRESSED CRUSHED AS IT WAS FURTHER CLARIFIED. THE PRODUCTS WERE STORED, HANDLED, AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU) AND THERE WAS NO DEVICE DAMAGE NOTICED PRIOR TO OPENING THE PACKAGES OR DIFFICULTY REMOVING THE DEVICES FROM THE STERILE PACKAGING. THERE WAS NO DIFFICULTY EXPERIENCED IN PREPPING THE DEVICES. THE PROCEDURE WAS COMPLETED USING AN UNKNOWN CORDIS DEVICE WITH A DIFFERENT SHAPE. ALL 4 DEVICES WERE DISCARDED AT SITE AFTER THE PROCEDURE AND WILL NOT BE RETURNED FOR EVALUATION. PICTURES ARE NOT AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18529191 ↗
  • MalfunctionJan 17, 2024Peeled/Delaminated; Peeled/Delaminated

    AS REPORTED, WHEN OPENING FOUR (4) 5F TEMPO 0.038 125CM GUIDING CATHETERS WERE FOUND BROKEN DISTALLY (CURVATURE) AND PROXIMALLY. THE DEVICES COULD NOT BE USED. THERE WAS NO REPORTED PATIENT INJURY. THE DAMAGE WAS NOTICED DURING THE PROCEDURE. THE SHAPE OF THE BODY/SHAFT WAS DESCRIBED AS "LIKE TURTLE OR FISH SCALES AT THE SHAPE"(TINY PIECES CRACKED BUT STILL ATTACHED TO ONE POINT ON THE CATHETER). THE BRAIDED CORE WIRE WAS NOT EXPOSED AND IT IS UNKNOWN IF THE CATHETERS WERE DELAMINATED OR COMPRESSED CRUSHED AS IT WAS FURTHER CLARIFIED. THE PRODUCTS WERE STORED, HANDLED, AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU) AND THERE WAS NO DEVICE DAMAGE NOTICED PRIOR TO OPENING THE PACKAGES OR DIFFICULTY REMOVING THE DEVICES FROM THE STERILE PACKAGING. THERE WAS NO DIFFICULTY EXPERIENCED IN PREPPING THE DEVICES. THE PROCEDURE WAS COMPLETED USING AN UNKNOWN CORDIS DEVICE WITH A DIFFERENT SHAPE. ALL 4 DEVICES WERE DISCARDED AT SITE AFTER THE PROCEDURE AND WILL NOT BE RETURNED FOR EVALUATION. PICTURES ARE NOT AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18528697 ↗
  • InjuryMar 15, 2021Detachment of Device or Device Component; Detachment of Device or Device Component

    AS REPORTED, THE 5F 0.038¿ 125CM II TEMPO DIAGNOSTIC CATHETER BROKE ABOUT 30CM FROM THE HUB DURING A STROKE PROCEDURE. THE DISTAL PART WAS LEFT IN THE AORTIC ARCH WHILE PROCEEDING WITH THE PROCEDURE AND LATER REMOVED FROM THE VESSEL WITH A SNARE. THE CATHETER HAD NOT YET BEEN PLACED IN THE CAROTID ARTERY. IT WAS MENTIONED THAT THIS HAPPENED WHEN THE DOCTOR TURNED THE CATHETER TWICE IN THE ARCH. THE CATHETER WAS INSERTED THROUGH A LONG SHEATH (NON-CORDIS). THE DOCTOR PULLED THE PROXIMAL PART OF THE CATHETER OUT AND CONTINUED THE PROCEDURE VIA THE LEFT GROIN. THE PROCEDURE (STROKE TREATMENT) WAS PERFORMED SUCCESSFULLY. AFTER FINISHING THE PROCEDURE, THE DISTAL PART OF THE CATHETER WAS SUCCESSFULLY CAPTURED WITH A SNARE. THE DEVICE WAS OPENED IN STERILE FIELD. THE LESION HAD MODERATE CALCIFICATION OF AORTIC ARCH. THERE WAS MODERATE VESSEL TORTUOSITY. THERE WAS NO STENOSIS. THE DEVICE WAS NOT USED FOR A CHRONIC TOTAL OCCLUSION (TOTAL OCCLUSION >3 MONTHS). THE DEVICE WAS NOT RESTERILIZED. THERE WERE NO ANOMALIES NOTED WHEN REMOVED FROM THE PACKAGE. THERE WERE NO ANOMALIES NOTED DURING PREP. THE DEVICE WAS INSERTED THROUGH A STOPCOCK INSTEAD OF A HEMOSTATIC VALVE. RESISTANCE WAS NOT MET

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11488238 ↗

Other CATHETER, INTRAVASCULAR, DIAGNOSTIC devices

All CATHETER, INTRAVASCULAR, DIAGNOSTIC devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.