TEMPO SRD5559Recalls & reported problems
Cordis Corporation · 5F TEMPO 0.038 125CM II · Class 2
All models of TEMPO (56)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 10705032048545), received between Mar 15, 2021 and Mar 6, 2026 — classified as 1 injury, 8 malfunctions.
The most frequently reported specific device problem is “Peeled/Delaminated” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Peeled/Delaminated4
- Degraded3
- Material Puncture/Hole3
- Detachment of Device or Device Component2
Patient problems
- No Clinical Signs, Symptoms or Conditions9
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 6, 2026Detachment of Device or Device Component
AS REPORTED, A 5F 125 CM TEMPO DIAGNOSTIC CATHETER BROKE OFF AT THE HUB DURING EXTRACTION FROM THE SHEATH. THE SEPARATED SEGMENT WAS BROKEN OFF IN THE PATIENT¿S BODY BUT WAS SUCCESSFULLY RETRIEVED. THERE WERE NO REPORTED INJURIES TO THE PATIENT. ADDITIONAL INFORMATION WAS REQUESTED BUT WAS NOT PROVIDED. THE DEVICE WAS NOT RETURNED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24532053 ↗MalfunctionJun 24, 2024Degraded; Material Puncture/Hole; Degraded; Material Puncture/Hole
AS REPORTED, FOUR 5F SIDEWINDER II TEMPO 0.038 125CM DIAGNOSTIC CATHETERS WERE FOUND TO BE CUT AT ANGULATION WITH RISK OF DETACHMENT IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER 5F TEMPO 0.038 125CM DIAGNOSTIC CATHETER OF A DIFFERENT LOT NUMBER. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICES WERE MEANT TO BE USED IN THROMBECTOMY PROCEDURES. OTHER PROCEDURAL DETAILS WERE REQUESTED BUT ARE UNKNOWN, UNAVAILABLE, NOT ANSWERED, OR NOT APPLICABLE. THE FOUR DEVICES USED WILL BE RETURNED FOR EVALUATION AS WELL AS ONE STERILE DEVICE AND ONE DEVICE THAT WAS OPENED BY MISTAKE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19594120 ↗MalfunctionJun 24, 2024Degraded; Material Puncture/Hole; Degraded; Material Puncture/Hole
AS REPORTED, FOUR 5F SIDEWINDER II TEMPO 0.038 125CM DIAGNOSTIC CATHETERS WERE FOUND TO BE CUT AT ANGULATION WITH RISK OF DETACHMENT IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER 5F TEMPO 0.038 125CM DIAGNOSTIC CATHETER OF A DIFFERENT LOT NUMBER. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICES WERE MEANT TO BE USED IN THROMBECTOMY PROCEDURES. OTHER PROCEDURAL DETAILS WERE REQUESTED BUT ARE UNKNOWN, UNAVAILABLE, NOT ANSWERED, OR NOT APPLICABLE. THE FOUR DEVICES USED WILL BE RETURNED FOR EVALUATION AS WELL AS ONE STERILE DEVICE AND ONE DEVICE THAT WAS OPENED BY MISTAKE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19594095 ↗MalfunctionJun 24, 2024Degraded; Material Puncture/Hole; Degraded; Material Puncture/Hole
AS REPORTED, FOUR 5F SIDEWINDER II TEMPO 0.038 125CM DIAGNOSTIC CATHETERS WERE FOUND TO BE CUT AT ANGULATION WITH RISK OF DETACHMENT IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER 5F TEMPO 0.038 125CM DIAGNOSTIC CATHETER OF A DIFFERENT LOT NUMBER. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICES WERE MEANT TO BE USED IN THROMBECTOMY PROCEDURES. OTHER PROCEDURAL DETAILS WERE REQUESTED BUT ARE UNKNOWN, UNAVAILABLE, NOT ANSWERED, OR NOT APPLICABLE. THE FOUR DEVICES USED WILL BE RETURNED FOR EVALUATION AS WELL AS ONE STERILE DEVICE AND ONE DEVICE THAT WAS OPENED BY MISTAKE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19594076 ↗MalfunctionJan 17, 2024Peeled/Delaminated; Peeled/Delaminated
AS REPORTED, WHEN OPENING FOUR (4) 5F TEMPO 0.038 125CM GUIDING CATHETERS WERE FOUND BROKEN DISTALLY (CURVATURE) AND PROXIMALLY. THE DEVICES COULD NOT BE USED. THERE WAS NO REPORTED PATIENT INJURY. THE DAMAGE WAS NOTICED DURING THE PROCEDURE. THE SHAPE OF THE BODY/SHAFT WAS DESCRIBED AS "LIKE TURTLE OR FISH SCALES AT THE SHAPE"(TINY PIECES CRACKED BUT STILL ATTACHED TO ONE POINT ON THE CATHETER). THE BRAIDED CORE WIRE WAS NOT EXPOSED AND IT IS UNKNOWN IF THE CATHETERS WERE DELAMINATED OR COMPRESSED CRUSHED AS IT WAS FURTHER CLARIFIED. THE PRODUCTS WERE STORED, HANDLED, AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU) AND THERE WAS NO DEVICE DAMAGE NOTICED PRIOR TO OPENING THE PACKAGES OR DIFFICULTY REMOVING THE DEVICES FROM THE STERILE PACKAGING. THERE WAS NO DIFFICULTY EXPERIENCED IN PREPPING THE DEVICES. THE PROCEDURE WAS COMPLETED USING AN UNKNOWN CORDIS DEVICE WITH A DIFFERENT SHAPE. ALL 4 DEVICES WERE DISCARDED AT SITE AFTER THE PROCEDURE AND WILL NOT BE RETURNED FOR EVALUATION. PICTURES ARE NOT AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18531157 ↗MalfunctionJan 17, 2024Peeled/Delaminated; Peeled/Delaminated
AS REPORTED, WHEN OPENING FOUR (4) 5F TEMPO 0.038 125CM GUIDING CATHETERS WERE FOUND BROKEN DISTALLY (CURVATURE) AND PROXIMALLY. THE DEVICES COULD NOT BE USED. THERE WAS NO REPORTED PATIENT INJURY. THE DAMAGE WAS NOTICED DURING THE PROCEDURE. THE SHAPE OF THE BODY/SHAFT WAS DESCRIBED AS "LIKE TURTLE OR FISH SCALES AT THE SHAPE"(TINY PIECES CRACKED BUT STILL ATTACHED TO ONE POINT ON THE CATHETER). THE BRAIDED CORE WIRE WAS NOT EXPOSED AND IT IS UNKNOWN IF THE CATHETERS WERE DELAMINATED OR COMPRESSED CRUSHED AS IT WAS FURTHER CLARIFIED. THE PRODUCTS WERE STORED, HANDLED, AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU) AND THERE WAS NO DEVICE DAMAGE NOTICED PRIOR TO OPENING THE PACKAGES OR DIFFICULTY REMOVING THE DEVICES FROM THE STERILE PACKAGING. THERE WAS NO DIFFICULTY EXPERIENCED IN PREPPING THE DEVICES. THE PROCEDURE WAS COMPLETED USING AN UNKNOWN CORDIS DEVICE WITH A DIFFERENT SHAPE. ALL 4 DEVICES WERE DISCARDED AT SITE AFTER THE PROCEDURE AND WILL NOT BE RETURNED FOR EVALUATION. PICTURES ARE NOT AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18529518 ↗MalfunctionJan 17, 2024Peeled/Delaminated; Peeled/Delaminated
AS REPORTED, WHEN OPENING FOUR (4) 5F TEMPO 0.038 125CM GUIDING CATHETERS WERE FOUND BROKEN DISTALLY (CURVATURE) AND PROXIMALLY. THE DEVICES COULD NOT BE USED. THERE WAS NO REPORTED PATIENT INJURY. THE DAMAGE WAS NOTICED DURING THE PROCEDURE. THE SHAPE OF THE BODY/SHAFT WAS DESCRIBED AS "LIKE TURTLE OR FISH SCALES AT THE SHAPE"(TINY PIECES CRACKED BUT STILL ATTACHED TO ONE POINT ON THE CATHETER). THE BRAIDED CORE WIRE WAS NOT EXPOSED AND IT IS UNKNOWN IF THE CATHETERS WERE DELAMINATED OR COMPRESSED CRUSHED AS IT WAS FURTHER CLARIFIED. THE PRODUCTS WERE STORED, HANDLED, AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU) AND THERE WAS NO DEVICE DAMAGE NOTICED PRIOR TO OPENING THE PACKAGES OR DIFFICULTY REMOVING THE DEVICES FROM THE STERILE PACKAGING. THERE WAS NO DIFFICULTY EXPERIENCED IN PREPPING THE DEVICES. THE PROCEDURE WAS COMPLETED USING AN UNKNOWN CORDIS DEVICE WITH A DIFFERENT SHAPE. ALL 4 DEVICES WERE DISCARDED AT SITE AFTER THE PROCEDURE AND WILL NOT BE RETURNED FOR EVALUATION. PICTURES ARE NOT AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18529191 ↗MalfunctionJan 17, 2024Peeled/Delaminated; Peeled/Delaminated
AS REPORTED, WHEN OPENING FOUR (4) 5F TEMPO 0.038 125CM GUIDING CATHETERS WERE FOUND BROKEN DISTALLY (CURVATURE) AND PROXIMALLY. THE DEVICES COULD NOT BE USED. THERE WAS NO REPORTED PATIENT INJURY. THE DAMAGE WAS NOTICED DURING THE PROCEDURE. THE SHAPE OF THE BODY/SHAFT WAS DESCRIBED AS "LIKE TURTLE OR FISH SCALES AT THE SHAPE"(TINY PIECES CRACKED BUT STILL ATTACHED TO ONE POINT ON THE CATHETER). THE BRAIDED CORE WIRE WAS NOT EXPOSED AND IT IS UNKNOWN IF THE CATHETERS WERE DELAMINATED OR COMPRESSED CRUSHED AS IT WAS FURTHER CLARIFIED. THE PRODUCTS WERE STORED, HANDLED, AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU) AND THERE WAS NO DEVICE DAMAGE NOTICED PRIOR TO OPENING THE PACKAGES OR DIFFICULTY REMOVING THE DEVICES FROM THE STERILE PACKAGING. THERE WAS NO DIFFICULTY EXPERIENCED IN PREPPING THE DEVICES. THE PROCEDURE WAS COMPLETED USING AN UNKNOWN CORDIS DEVICE WITH A DIFFERENT SHAPE. ALL 4 DEVICES WERE DISCARDED AT SITE AFTER THE PROCEDURE AND WILL NOT BE RETURNED FOR EVALUATION. PICTURES ARE NOT AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18528697 ↗InjuryMar 15, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
AS REPORTED, THE 5F 0.038¿ 125CM II TEMPO DIAGNOSTIC CATHETER BROKE ABOUT 30CM FROM THE HUB DURING A STROKE PROCEDURE. THE DISTAL PART WAS LEFT IN THE AORTIC ARCH WHILE PROCEEDING WITH THE PROCEDURE AND LATER REMOVED FROM THE VESSEL WITH A SNARE. THE CATHETER HAD NOT YET BEEN PLACED IN THE CAROTID ARTERY. IT WAS MENTIONED THAT THIS HAPPENED WHEN THE DOCTOR TURNED THE CATHETER TWICE IN THE ARCH. THE CATHETER WAS INSERTED THROUGH A LONG SHEATH (NON-CORDIS). THE DOCTOR PULLED THE PROXIMAL PART OF THE CATHETER OUT AND CONTINUED THE PROCEDURE VIA THE LEFT GROIN. THE PROCEDURE (STROKE TREATMENT) WAS PERFORMED SUCCESSFULLY. AFTER FINISHING THE PROCEDURE, THE DISTAL PART OF THE CATHETER WAS SUCCESSFULLY CAPTURED WITH A SNARE. THE DEVICE WAS OPENED IN STERILE FIELD. THE LESION HAD MODERATE CALCIFICATION OF AORTIC ARCH. THERE WAS MODERATE VESSEL TORTUOSITY. THERE WAS NO STENOSIS. THE DEVICE WAS NOT USED FOR A CHRONIC TOTAL OCCLUSION (TOTAL OCCLUSION >3 MONTHS). THE DEVICE WAS NOT RESTERILIZED. THERE WERE NO ANOMALIES NOTED WHEN REMOVED FROM THE PACKAGE. THERE WERE NO ANOMALIES NOTED DURING PREP. THE DEVICE WAS INSERTED THROUGH A STOPCOCK INSTEAD OF A HEMOSTATIC VALVE. RESISTANCE WAS NOT MET
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11488238 ↗
FDA clearance and classification
Cleared through Special 510(k) K181836 on Aug 8, 2018 (decision: Substantially Equivalent). Submitted by Cordis, A Cardinal Health Company as “4F Infiniti Angiographic Catheter, 4F & 5F Nylex Angiography Catheters, 4F & 5F Tempo Angiography Catheters”. The FDA review took 29 days. FDA record ↗
The FDA regulates product code DQO (catheter, intravascular, diagnostic) under 21 CFR 870.1200 as a Class II device. 21 CFR 870.1200 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the TEMPO SRD5559
Has the TEMPO SRD5559 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10705032048545), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the TEMPO SRD5559?
The FDA's MAUDE database lists 9 adverse event reports for this device, received between Mar 15, 2021 and Mar 6, 2026. In those reports, the most common specific device problems are “Peeled/Delaminated” (4), “Degraded” (3) and “Material Puncture/Hole” (3). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the TEMPO SRD5559?
None of the reports are classified as deaths, 1 as an injury and 8 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the TEMPO SRD5559 FDA approved?
It was cleared through Special 510(k) K181836 on Aug 8, 2018. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the TEMPO SRD5559, and is it still sold?
The FDA's device database lists Cordis Corporation as the company responsible for it (brand TEMPO, model SRD5559). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other CATHETER, INTRAVASCULAR, DIAGNOSTIC devices
- TrapEase Permanent Vena Cava Filter with the VisEase Angiographic Vessel Dilator 466P306AUCordis Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC6 deaths186 reports
- Dragonfly™ OPTIS™ C408646Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC4 deaths150 reports
- Dragonfly OpStar™ 1014651Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC1 recall87 reports
- LANGSTON IPN913559Teleflex Incorporated · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls14 reports
- Trevo 90238Stryker Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls5 reports
- Expo™ H749085263011Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls3 reports
- Expo™ H74908526501Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls1 report
- Expo™ H74908526031Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page