EXPEDIUM 179712045Recalls & reported problems
Medos International Sàrl · EXPEDIUM SPINE SYSTEM SI POLYAXIAL SCREW 5.5 x 7.5 x 45mm · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 6
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 10705034066592), received between Oct 27, 2017 and Sep 19, 2022 — classified as 6 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem5
- Break1
- Device Dislodged or Dislocated1
- Unintended Movement1
Patient problems
- Dizziness5
- Hypersensitivity/Allergic reaction5
- Neurological Deficit/Dysfunction5
- Failure of Implant1
- No Clinical Signs, Symptoms or Conditions1
- No Code Available1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 19, 2022Break; Break
IT WAS REPORTED THAT ON (B)(6) 2022, THE TOP OF THE PEDICLE SCREW THAT ENGAGES WITH THE HEAD OF THE SCREW POPPED UP INTO THE HEAD WHILE THE SCREW WAS BEING INSERTED. THE SCREW HAD TO BE REMOVED AND REPLACED DUE TO THE PIECE BEING IN THE WAY OF PUTTING A ROD INTO PLACE. THERE WAS A SURGICAL DELAY OF 10 MINUTES. PROCEDURE WAS SUCCESSFULLY COMPLETED. THIS REPORT INVOLVES ONE EXPEDIUM SPINE SYSTEM SI POLYAXIAL SCREW 5.5 X 7.5 X 45MM. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15446613 ↗InjuryDec 6, 2019Unintended Movement; Unintended Movement
IT WAS REPORTED THAT ON (B)(6) 2019 SURGEON REVISED A LUMBAR FUSION CONSTRUCT (L2-L5), THE SET SCREW AT THE TOP OF THE CONSTRUCT (L2 LEFT PEDICLE) HAD BECOME DISLODGED FROM THE TULIP HEAD AND WAS ADJACENT TO THE CONSTRUCT ON THE LEFT SIDE. SURGEON OBSERVED "HALOING" AROUND THE L2 PEDICLE SCREWS BILATERALLY AND INTENDED TO REVISE. THE RIGHT SIDE OF THE CONSTRUCT WAS SECURELY INTACT, RODS REMOVED BILATERALLY AND REPLACED THE R SIDE L2 CORTICAL FIX POLYAXIAL SCREW 7 X 45 MM WITH A HALF DIAMETER LARGER EXPEDIUM SPINE SYSTEM SI POLYAXIAL SCREW 7.5 MM X 45 MM. SURGEON CONTINUED ON TO REMOVE THE HARDWARE BELOW (SPINEART ROMEO PEDICLE SCREW SYSTEM AT L3-5) AND REPLACED THE HARDWARE WITH EXPEDIUM 5.5 AND PROCEEDED TO EXPOSURE, CANNULATE, AND PLACE BILATERAL PEDICLE SCREWS AT L1, THEN PLACED A 5.5. TI ROD FROM L1-4 (04.636.125 X 2), INSERTED NEW SINGLE INNER SET CAPS AND SUCCESSFULLY FINAL TIGHTENED WITH THE TORQUE DRIVER AND COUNTER TORQUE WITHOUT INCIDENT. CONCOMITANT DEVICE REPORTED: UNKNOWN ROD (PART # UNKNOWN, LOT # UNKNOWN, QUANTITY 1). THIS COMPLAINT INVOLVES FIVE (5) DEVICES. THIS IS 3 OF 5 FOR REPORT (B)(4).
Patient problems: Failure of Implant; No Code Available
MAUDE report 9426306 ↗InjuryFeb 12, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED BY LEGAL THAT PATIENT HAD SEVERAL POST OP ISSUES FOLLOWING POSTERIOR SPINAL INSTRUMENTATION WITH DEPUY EXPEDIUM (L5-S1). LEFT L5-S1 TRANSFORAMINAL LUMBAR INTERBODY FUSION WITH PLACEMENT OF A DEPUY DEVEX 10 X 28 TRANSFORAMINAL LUMBAR INTERBODY FUSION TITANIUM CAGE AND ANTERIOR SPINAL FUSION WITH AUTOGRAFT AT L5-S1. UNEVENTFUL SURGERY PER OP REPORT. NOTHING OUT OF THE ORDINARY.
Patient problems: Dizziness; Hypersensitivity/Allergic reaction; Neurological Deficit/Dysfunction
MAUDE report 7263990 ↗InjuryFeb 12, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED BY LEGAL THAT PATIENT HAD SEVERAL POST OP ISSUES FOLLOWING POSTERIOR SPINAL INSTRUMENTATION WITH DEPUY EXPEDIUM (L5-S1). LEFT L5-S1 TRANSFORAMINAL LUMBAR INTERBODY FUSION WITH PLACEMENT OF A DEPUY DEVEX 10 X 28 TRANSFORAMINAL LUMBAR INTERBODY FUSION TITANIUM CAGE AND ANTERIOR SPINAL FUSION WITH AUTOGRAFT AT L5-S1. UNEVENTFUL SURGERY PER OP REPORT. NOTHING OUT OF THE ORDINARY.
Patient problems: Dizziness; Hypersensitivity/Allergic reaction; Neurological Deficit/Dysfunction
MAUDE report 7263838 ↗InjuryFeb 12, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED BY LEGAL THAT PATIENT HAD SEVERAL POST OP ISSUES FOLLOWING POSTERIOR SPINAL INSTRUMENTATION WITH DEPUY EXPEDIUM (L5-S1). LEFT L5-S1 TRANSFORAMINAL LUMBAR INTERBODY FUSION WITH PLACEMENT OF A DEPUY DEVEX 10 X 28 TRANSFORAMINAL LUMBAR INTERBODY FUSION TITANIUM CAGE AND ANTERIOR SPINAL FUSION WITH AUTOGRAFT AT L5-S1. UNEVENTFUL SURGERY PER OP REPORT. NOTHING OUT OF THE ORDINARY. SEE ATTACHMENT "PATIENT MEDICAL HISTORY SUMMARY"
Patient problems: Dizziness; Hypersensitivity/Allergic reaction; Neurological Deficit/Dysfunction
MAUDE report 7263648 ↗InjuryFeb 12, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED BY LEGAL THAT PATIENT HAD SEVERAL POST OP ISSUES FOLLOWING POSTERIOR SPINAL INSTRUMENTATION WITH DEPUY EXPEDIUM (L5-S1). LEFT L5-S1 TRANSFORAMINAL LUMBAR INTERBODY FUSION WITH PLACEMENT OF A DEPUY DEVEX 10 X 28 TRANSFORAMINAL LUMBAR INTERBODY FUSION TITANIUM CAGE AND ANTERIOR SPINAL FUSION WITH AUTOGRAFT AT L5-S1. UNEVENTFUL SURGERY PER OP REPORT. NOTHING OUT OF THE ORDINARY.
Patient problems: Dizziness; Hypersensitivity/Allergic reaction; Neurological Deficit/Dysfunction
MAUDE report 7263534 ↗InjuryFeb 12, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED BY LEGAL THAT PATIENT HAD SEVERAL POST OP ISSUES FOLLOWING POSTERIOR SPINAL INSTRUMENTATION WITH DEPUY EXPEDIUM (L5-S1). LEFT L5-S1 TRANSFORAMINAL LUMBAR INTERBODY FUSION WITH PLACEMENT OF A DEPUY DEVEX 10 X 28 TRANSFORAMINAL LUMBAR INTERBODY FUSION TITANIUM CAGE AND ANTERIOR SPINAL FUSION WITH AUTOGRAFT AT L5-S1. UNEVENTFUL SURGERY PER OP REPORT. NOTHING OUT OF THE ORDINARY.
Patient problems: Dizziness; Hypersensitivity/Allergic reaction; Neurological Deficit/Dysfunction
MAUDE report 7263520 ↗MalfunctionOct 27, 2017Device Dislodged or Dislocated; Device Dislodged or Dislocated
AFTER IMPLANTING THE SCREW, THE SURGEON REMOVED A LOOSE PIECE OF A SCREW. IT WAS THE ¿U¿ SHAPED PIECE INSIDE THE POLYAXIAL HEAD OF THE SCREW. HE REMOVED THE SCREW AND REPLACED IT WITH ANOTHER ONE OF THE SAME SIZE.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6984558 ↗
Other Orthosis, spinal pedicle fixation, for degenerative disc disease devices
- EXPEDIUM VERSE 199721000Medos International Sàrl · Orthosis, spinal pedicle fixation, for degenerative disc disease387 reports
- Sequoia® 3301-1Zimmer Spine, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease184 reports
- CD HORIZON® Spinal System 8590855Medtronic Sofamor Danek, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease179 reports
- Vitality® 07.02011.001Biomet Spine LLC · Orthosis, spinal pedicle fixation, for degenerative disc disease3 recalls0 reports
- EXPEDIUM VERSE 199721001SMedos International Sàrl · Thoracolumbosacral pedicle screw system124 reports
- LineSider LS-N6SA7550Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls1 report
- LineSider LS-N6SA6545Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls0 reports
- EXPEDIUM VERSE 199721000SMedos International Sàrl · Thoracolumbosacral pedicle screw system97 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page