EXPEDIUM 179732745Recalls & reported problems
Medos International Sàrl · EXPEDIUM SPINE SYSTEM SI POLYAXIAL EXTEND TAB 5.5 x 7.0 x 45mm · Class 2 · Implant
All models of EXPEDIUM (291)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10705034074047), received between Jun 29, 2020 and Dec 27, 2023 — classified as 2 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
- Detachment of Device or Device Component1
- Material Deformation1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Foreign Body In Patient1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryDec 27, 2023Break; Break
IT WAS REPORTED THAT THE PATIENT HAD AN L4-5 TLIF (TRANSFORAMINAL LUMBAR INTERBODY FUSION) ON (B)(6) 2022 WITH THE EXPEDIUM SCREWS AND A NON-SYNTHES EXPANDABLE CAGE. UPON POST-OP FOLLOWUP ON AUGUST 2, 2023, THE SURGEON DISCOVERED A BROKEN SCREW AT L5 RIGHT. A REVISION SURGERY WAS SCHEDULED FOR (B)(6) 2024 FOR IMPLANT REMOVAL AND CONSTRUCT EXTENSION. THIS REPORT INVOLVES ONE EXPEDIUM SPINE SYSTEM SI POLYAXIAL EXTEND TAB 5.5 X 7.0 X 45MM. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18399543 ↗MalfunctionSep 15, 2022Detachment of Device or Device Component; Detachment of Device or Device Component
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN CHINA AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2022, WHEN SCREWING THE PEDICLE SCREW DURING SURGERY, THE SCREW ROD SEPARATED FROM THE LONG TAIL OF SCREW CAP. THE SURGEON REMOVED THE DETACHED SCREW ROD AND CAP FROM THE PATIENT, AND CHANGED TO ANOTHER DEVICE TO COMPLETE THE SURGERY. THIS CAUSED THE SURGERY TO BE EXTENDED FOR ABOUT 1.5 HOURS. THE PATIENT IS REPORTED AS STABLE. THIS REPORT INVOLVES ONE EXPEDIUM SPINE SYSTEM SI POLYAXIAL EXTEND TAB 5.5 X 7.0 X 45MM. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15427188 ↗InjuryAug 1, 2022Break; Break
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN JAPAN AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2022, THE PATIENT UNDERWENT A REVISION PROCEDURE, LUMBAR SPINAL FUSION. AFTER REMOVING A SCREW, THE SURGEON MOVED ON TO INSERTING A CFS 8MM SCREW WITH THE SCREWDRIVER. THEN, THE SCREWDRIVER¿S TIP BROKE OFF. THE FRAGMENTED TIP WAS IMMOVABLE IN THE SCREW¿S SHANK AND HAS BEEN LEFT IN THE LESION. THIS REPORT INVOLVES ONE (1) EXPEDIUM SPINE SYSTEM SI POLYAXIAL EXTEND TAB 5.5 X 7.0 X 45MM. THIS IS REPORT 2 OF 2 FOR (B)(4).
Patient problems: Foreign Body In Patient
MAUDE report 15140685 ↗MalfunctionJun 29, 2020Material Deformation; Material Deformation
THIS COMPLAINT INVOLVES TWO (2) DEVICES.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10205691 ↗
FDA clearance and classification
The FDA regulates product code KWP (appliance, fixation, spinal interlaminal) under 21 CFR 888.3050 as a Class II device. 21 CFR 888.3050 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the EXPEDIUM 179732745
Has the EXPEDIUM 179732745 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10705034074047), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the EXPEDIUM 179732745?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between Jun 29, 2020 and Dec 27, 2023. In those reports, the most common specific device problems are “Break” (2), “Detachment of Device or Device Component” (1) and “Material Deformation” (1); the most common patient problem is “Foreign Body In Patient” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the EXPEDIUM 179732745?
None of the reports are classified as deaths, 2 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the EXPEDIUM 179732745 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the EXPEDIUM 179732745, and is it still sold?
The FDA's device database lists Medos International Sàrl as the company responsible for it (brand EXPEDIUM, model 179732745). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other APPLIANCE, FIXATION, SPINAL INTERLAMINAL devices
- EXPEDIUM 179702000Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL433 reports
- EXPEDIUM VERSE 199721001Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL227 reports
- XIA 3 48230000Stryker Corporation · APPLIANCE, FIXATION, SPINAL INTERLAMINAL193 reports
- VIPER 186715000Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL1 death167 reports
- NA 04.614.014Synthes GmbH · APPLIANCE, FIXATION, SPINAL INTERLAMINAL80 reports
- NA 04.615.014Synthes GmbH · APPLIANCE, FIXATION, SPINAL INTERLAMINAL72 reports
- EXPEDIUM VIPER 196789480Depuy Spine, LLC · APPLIANCE, FIXATION, SPINAL INTERLAMINAL72 reports
- Arsenal Deformity Spinal Fixation System 47127Alphatec Spine, Inc. · APPLIANCE, FIXATION, SPINAL INTERLAMINAL66 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page