EXPEDIUM 179712740SRecalls & reported problems

Medos International Sàrl · EXPEDIUM SPINE SYSTEM SI POLYAXIAL SCREW 5.5 x 7 x 40mm · Class 2 · Implant

All models of EXPEDIUM (291)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10705034267081), received between Dec 13, 2023 and Mar 12, 2024 — classified as 2 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 3 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Break1
  • Device-Device Incompatibility1

Patient problems

  • Osteolysis2
  • Insufficient Information1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 12, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PRODUCT REMAINS INSITU IN PATIENT. THE PATIENT IS STABLE.

    Patient problems: Osteolysis

    MAUDE report 18885759 ↗
  • InjuryMar 12, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PRODUCT REMAINS INSITU IN PATIENT. THE PATIENT IS STABLE.

    Patient problems: Osteolysis

    MAUDE report 18885753 ↗
  • MalfunctionMar 12, 2024Break; Break

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN IRELAND AS FOLLOWS: IT WAS REPORTED THAT THE REVISION FUSION WAS UNDERTAKEN AND ALL EXISTING INNER SET SCREWS AND RODS WERE REMOVED. ALL SCREWS APPEARED INTACT, AND THE SURGEON PULLED ON EACH SCREW TO DOUBLE CHECK INTEGRITY. UPON PULLING ON THE SCREW AT L3 ON THE LEFT SIDE, THE POLYAXIAL COMPONENT CAME AWAY. THE SURGEON PROCEEDED TO INSERT NEW SCREWS CAUDALLY AND CRANIALLY AND OPTED TO LEAVE THE DISTAL SCREW SHAFT IN SITU. REVISION SURGERY WAS PERFORMED TO TREAT ADJACENT SEGMENT ISSUES BY INSERTING NEW SCREWS CAUDALLY AND CRANIALLY. THE DISTAL COMPONENT OF THE BROKEN SCREW REMAINED IN THE PATIENT. THERE WAS A CONSEQUENCE FOR THE PATIENT DUE TO THE EVENT, AS IT RESULTED IN A SECOND PROCEDURE. A BROKEN COMPONENT OF THE SCREW REMAINED IN THE PATIENT. THERE WAS NO SURGICAL DELAY. THIS REPORT IS FOR ONE (1) SI POLYAXL SCREW 7 X 40MM THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).

    Patient problems: Insufficient Information

    MAUDE report 18884848 ↗
  • MalfunctionDec 13, 2023Device-Device Incompatibility; Device-Device Incompatibility

    DEVICE REPORT FROM SWEDEN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE ON 21-NOVEMBER-2023, AN EXPEDIUM SCREW WAS PLACED ON THE EXPEDIUM SCREWDRIVER. WHEN INSERTING THE SCREW INTO THE PEDICLE THE SCREWDRIVER BROKE, AND THE TIP OF THE SCREWDRIVER REMAINED STUCK IN THE SCREW HEAD. THE SCREW WAS REMOVED USING OTHER DEVICES AND WAS REPLACED BY A NEW SCREW USING ANOTHER SCREWDRIVER. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A SURGICAL DELAY OF 5 MINUTES. THERE WAS NO ADVERSE PATIENT IMPACT. ALL GENERATED FRAGMENTS WERE REMOVED WITHOUT ADDITIONAL MEDICAL INTERVENTION. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR AN EXPEDIUM SPINE SYSTEM SI POLYAXIAL SCREW 5.5 X 7 X 40MM. THIS IS REPORT 1 OF 2 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18318331 ↗